1 of 1

Schneider Altistart 22 ATS22C59S6 Soft Starter

Schneider Altistart 22 ATS22C59S6 Soft Starter

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22C59S6

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 41250g

  • Dimensions: 57,5cm x 40cm x 53,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS22C59S6 is an Altistart 22 soft starter designed for the smooth starting and stopping of high-power three-phase asynchronous motors. This unit is rated for a continuous operational current of 590 A and is compatible with supply voltages ranging from 230 V to 600 V. It provides power control for motors between 160 kW and 400 kW, utilizing internal torque management to minimize mechanical stress on drive components and mitigate voltage drops during startup. The ATS22C59S6 includes an integrated bypass contactor, which helps reduce energy losses and heat dissipation during steady-state operation.

Features

  • Rated operational current: 590 A
  • Supply voltage range: 230 V to 600 V
  • Motor power capacity: 160 kW to 400 kW
  • Integrated bypass contactor for thermal efficiency
  • Advanced motor protection and diagnostic monitoring
  • Compact physical design optimized for high-power industrial cabinets

Applications

  • Large-scale centrifugal and axial pumps
  • High-power fan and blower systems
  • Industrial compressors
  • Heavy-load conveyors and material handling
  • Large gear-driven machinery

Technical Specifications

Specification Details
Manufacturer Schneider Electric
Range Altistart
Subrange 22
Product Type Soft starters
Rated Current 590 A
Voltage Range 230-600 V
Motor Power Rating 160 - 400 kW
Dimensions 57.5 x 40 x 53.5 cm
Weight 41.25 kg
Commodity Code 84798997
Product Status Active

Installation Guidelines

  • Mounting: Mount the soft starter in a vertical position on a robust, fire-resistant surface capable of supporting the unit's weight.
  • Ventilation: Ensure adequate airflow through the heat sink area. Adhere to specified clearances above and below the device to prevent thermal derating.
  • Wiring: Use power cabling sized for a 590 A current rating. Ensure all high-power terminal connections are properly torqued to prevent resistive heating and electrical faults.
  • Grounding: A reliable connection to the system protective earth (PE) is required to ensure electromagnetic compatibility and personnel safety.
  • Environment: Install in a clean, climate-controlled cabinet, as accumulation of dust or exposure to moisture can compromise performance and lifespan.

What is the rated operational current of the ATS22C59S6?

This model is rated for 590 A.

What is the motor power range supported by this soft starter?

The unit supports asynchronous motors with power ratings between 160 kW and 400 kW.

Does this soft starter have an internal bypass?

Yes, it features an integrated bypass contactor to reduce internal power dissipation during normal motor operation.

What are the dimensions for cabinet mounting purposes?

The device measures 57.5 cm by 40 cm by 53.5 cm.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...