1 of 1

Schneider Modicon Premium TSXCBY500KT Bus-X Cable

Schneider Modicon Premium TSXCBY500KT Bus-X Cable

Only 8 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: TSXCBY500KT

  • Country of origin:France

  • Product Type: Accessories

  • Payment: T/T, Western Union

  • Weight: 6300g

  • Dimensions: 50cm x 50cm x 7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The TSXCBY500KT is a Bus-X cable designed specifically for the Modicon Premium automation platform. Engineered by Schneider Electric, this cable facilitates critical data communication between PLC components or distributed I/O racks. The cable features two high-reliability SUB-D 9 connectors and spans a length of 50 meters, providing the reach necessary for complex industrial configurations. As a dedicated accessory for the Modicon Premium series, it ensures stable signal integrity for process control applications, making it an essential component for the maintenance and expansion of existing automation infrastructure.

Features

  • Connector type: 2 x SUB-D 9
  • Length: 50 meters
  • Application: Modicon Premium Bus-X communication
  • Robust construction for industrial environments
  • Ensures high-performance signal integrity between modules

Applications

  • Multi-rack PLC system communication
  • Distributed I/O rack connectivity
  • Legacy system maintenance and expansion
  • Industrial automation networking

Technical Specifications

Attribute Specification
Manufacturer Schneider Electric
Brand Schneider Electric
Product Range Modicon Premium
Model TSXCBY500KT
Product Type Accessories (Bus-X cable)
Connectors 2 x SUB-D 9
Cable Length 50m
Weight 6.30kg
Dimensions 50 x 50 x 7 cm
Commodity Code 85444290
PLM Product Phase Phase-Out

Installation Guidelines

  • Ensure the PLC system is powered down before connecting or disconnecting the Bus-X cable to prevent potential hardware damage.
  • When routing the cable, avoid sharp bends or mechanical stress on the SUB-D 9 connectors to maintain long-term signal stability.
  • Keep the cable away from high-voltage power lines and sources of high electromagnetic interference (EMI) to prevent data corruption.
  • Use the integrated locking screws on the SUB-D 9 connectors to secure the cable to the module port, ensuring a vibration-resistant connection.
  • Inspect the cable periodically for signs of abrasion or damage, especially if installed in high-traffic or harsh industrial areas.

What is the primary function of the TSXCBY500KT?

This is a Bus-X communication cable used to connect components within the Modicon Premium PLC platform.

What connectors does this cable use?

The cable is equipped with two SUB-D 9 connectors.

What is the total length of this cable?

The TSXCBY500KT is 50 meters long.

What safety measure should be followed during installation?

Always disconnect power from the PLC system before plugging or unplugging the cable to avoid electrical faults.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Maye Güc Sistemlərini Əvəz Etmək Üçün Dizayn Edilmiş Elektrik Aktuatorları: Praktik Sənaye Avtomatlaşdırma Bələdçisi

Bu məqalə SMC-nin e-Actuator seriyası kimi inteqrasiya olunmuş elektrik aktuatorlarının ənənəvi pnevmatik və hidravlik sistemləri əvəz etməklə sənaye hərəkət nəzarətini necə dəyişdirdiyini izah edir....

Sənaye Avtomatlaşdırma Tətbiqləri üçün OpenPLC ilə Riyazi Əməliyyatlar

Bu məqalə PLC sistemlərinin sənaye avtomatlaşdırmasında toplama, çıxma, vurma, bölmə, modulo və qüvvətə qaldırma kimi əsas riyazi əməliyyatları necə yerinə yetirdiyini izah edir. Məqalədə bu...

FBD PLC Proqramlaşdırmada Təkmil Boolean Məntiqi: Əsas Məntiqdən Kənar Praktiki Sənaye Tətbiqləri

Məqalə, PLC proqramlaşdırmada əsas AND, OR və NOT əməliyyatlarından kənar istifadə olunan bir neçə inkişaf etmiş Boolean məntiq funksiyalarını izah edir. O, Həqiqət cədvəlləri, çoxlayıcılar, impuls...

PLC Proqramlaşdırmada Boolean Məntiqi: FBD Məntiq Qapılarını Anlamaq

Boolean məntiqi hər bir PLC proqramının əsasını təşkil edir. Sadə maşın idarəetmələrindən mürəkkəb sənaye avtomatlaşdırma sistemlərinə qədər, məntiq qapıları nəzarətçilərin dəyişən girişlərə və...