1 от 3

ABB SDCS-FEX-2A (3ADT311500R1) DCS Drives Field Exciter Power Supply Board

ABB SDCS-FEX-2A (3ADT311500R1) DCS Drives Field Exciter Power Supply Board

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: SDCS-FEX-2A 3ADT311500R1

  • Country of origin:Финландия,Германия

  • Product Type: Field Exciter Power Supply Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 270 mm x 195 mm x 80 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The ABB SDCS-FEX-2A is an integrated single-phase field exciter and power supply circuit board engineered for internal mounting within armature converter modules. Functioning as a digital field exciter board, this module consists of an integrated power part and an onboard control processor section that links all internal components both electrically and mechanically.

The SDCS-FEX-2A is designed explicitly for installation inside ABB DCS converter modules of type C1, C2, and C3 alongside the electronic power supply board SDCS-POW-1, but is completely incompatible with C4 frame sizes. Operating with a wide single-phase rated input voltage range from 110V to 500V AC and a maximum current capacity of 16A, the 3ADT311500R1 uses a fully digital micro-controller layout to dynamically scale its active burden resistors, ensuring optimal signal resolution across an automated selection band between 3A and 16A.

Features

  • Half-Controlled Bridge Rectification: Built using two internal diode-thyristor modules configured as a single-phase half-controlled bridge for high-efficiency motor field winding control.
  • Onboard 80C198 Micro-controller: Features a dedicated embedded 80C198 micro-controller execution unit running localized PI firmware loop algorithms for direct current stabilization.
  • Automated Burden Scaling: Dynamically selects internal hardware burden resistors depending on the motor nominal field parameters to maximize control accuracy.
  • Integrated Surge Defenses: Equipped with dual Metal Oxide Varistors (MOVs) providing simultaneous transient voltage spike dampening across the AC input side and the inductive DC output circuits.

Applications

  • Internal motor field excitation and closed-loop DC current regulation inside ABB DCS500 and DCS600 converter units.
  • Heavy industrial drive lineups including variable-speed fan groups, crane hoist infrastructure, and heavy extrusion systems.

Technical Specifications

Parameter Specification
Manufacturer ABB
Model Designation SDCS-FEX-2A
Product ID / Order Number 3ADT311500R1
Control Architecture Digital 80C198 Micro-controller
AC Input Voltage Range 110V to 500V single-phase AC
Maximum Current Output 16A
Automatic Current Selection Ranges From 3A down to 16A resolution steps
Serial Interface Protocol RS485 link to SDCS-CON-x board
Fixed Communication Device Address Node number = 1
Part Type Status Original / New
Country of Origin Finland (FI) / Germany (DE)
Shipping Weight (Calculated) 0.65 kg
Package Dimensions (Calculated) 270 mm x 195 mm x 80 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The SDCS-FEX-2A module is specifically engineered for frame integration into DCS type C1, C2, and C3 converter modules. Do not attempt mechanical or electrical structural mounting inside larger type C4 converter bays, as the ventilation flows, structural sizing, and communication path cabling are completely non-interchangeable. The module retains a permanent fixed RS485 network routing identifier at Node Address 1, which requires strict configuration adherence on the accompanying master SDCS-CON-x board layout.

Application Pitfalls & Engineering Notes

During initialization, the onboard microcontroller depends on real-time parameter streaming from the main armature processor memory via flat cable X14. If an interruption occurs in the RS485 communication link or parameter table configuration values fail to deploy correctly, the field control software will fail to scale the internal burden resistors, causing zero-current tracking faults. Additionally, when testing output loop values via the terminal row X20:, external multi-meters must maintain an internal operational resistance greater than 1M Ohm to prevent short-circuit conditions or measuring errors.

Installation Guidelines

CRITICAL WARNING: LETHAL HIGH VOLTAGE AC/DC POTENTIALS

Isolate, switch off, and safety lockout all incoming three-phase AC feeder lines and distinct single-phase excitation voltage links supplying the converter chassis. Internal storage capacitors preserve high-energy electrical charges after supply line termination. Allow a minimum of 15 minutes for safety bleed-down to discharge completely, and verify a zero-energy state across all terminals with a calibrated testing device before handling internal circuitry.

1
Fasten a verified static protection grounding strap to your arm and clamp the grounding wire tightly onto an unpainted steel frame element of the earth-grounded control enclosure.
2
Carefully detach the low-voltage flat ribbon connection assembly from interface port X14: and safely unscrew the main AC supply and motor inductive field output lines.
3
Align the replacement card frame onto the inner mounting channel alongside the SDCS-POW-1 power component, torque retaining hardware down to lock the ground loop path, and reconnect all cables.

Can this field exciter board be deployed in DCS type C4 converter modules?

No, this module is built strictly for physical configuration and installation inside smaller type C1, C2, and C3 armature converter housings.

How does the module measure internal DC output current using an AC transformer?

The diode-thyristor anodes route through the primary winding of the AC transformer, utilizing a center-tap negative rectifier node to execute AC current transformation.

What is the mandatory internal resistance for tools connected to terminal row X20?

External measuring devices must maintain an input resistance greater than 1M Ohm to protect the diagnostic circuit loops and prevent terminal shorting.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Зелен
Country of origin
Финландия Германия

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...