1 от 3

Allen-Bradley 1794-IB8 FLEX I/O Digital Input Module

Allen-Bradley 1794-IB8 FLEX I/O Digital Input Module

Only 4 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-IB8

  • Country of origin:Съединени щати

  • Product Type: FLEX I/O Digital Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 46 mm x 94 mm x 53 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The 1794-IB8 is a discrete hardware component engineered for the FLEX I/O distributed input/output platform. This 24V DC digital input module is designed to monitor binary field conditions by converting high-level voltage potentials from industrial sensing devices into digital status bits for the system processor. Operating as a sinking configuration, the unit senses current passing from sourcing field elements through its input circuitry to the common return rail, establishing a clean interface between physical plant switches and digital logic registers.

Equipped with eight independent, non-isolated input channels, the device routes field signals back to a centralized programmable logic controller via a compatible FLEX I/O network adapter across EtherNet/IP, ControlNet, or DeviceNet backplanes. The 1794-IB8 plugs directly into a specialized terminal base unit that anchors the module to standard industrial mounting frameworks. This module type is typically integrated into manufacturing applications, material handling facilities, logistics sorting hubs, and water infrastructure management panels requiring low-channel-count, reliable sensor aggregation.

Features

  • Eight discrete sinking input channels for low-density distributed field monitoring.
  • 24V DC nominal operation matching standard industrial proximity sensors and switches.
  • Support for Removal and Insertion Under Power (RIUP) to facilitate rapid maintenance cycles.
  • Individual front-facing LED indicators displaying real-time digital status for each input loop.
  • Integrated software filtering configurations to reduce signal bounce from mechanical contacts.

Applications

  • Proximity sensor and photoelectric eye array state tracking.
  • Pushbutton stations and selector switch monitoring.
  • Conveyor line jam switch and sorting gate alignment verification.
  • Mechanical limit switch safety interlock logging.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O
Part Number 1794-IB8
Module Type Digital Sinking Input Module
Number of Inputs 8 Channels, Non-Isolated
Nominal Input Voltage 24V DC
On-State Voltage Range 10V DC to 31.2V DC
On-State Current Limit 2.0 mA minimum, 12.0 mA maximum
Off-State Voltage Range 5.0V DC maximum
Off-State Current Limit 1.5 mA maximum
Input Impedance 3.4 kilohms maximum
FlexBus Current Draw 30 mA at 5V DC
Input Filter Time (On to Off) Programmable (0.25 ms nominal to 8.0 ms maximum)
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin USA
Weight 0.08 kg
Dimensions 46 mm x 94 mm x 53 mm

Connections/Interfaces

Terminal Base Pin Location Function / Signal Assignment
Terminal 0 to Terminal 7 Input Signal Connection Nodes 0 through 7
+V (External Power) 24V DC Sourcing Sensor Voltage Supply Terminal
COM (External Power) Shared DC Return Reference Connection

Installation Guidelines

DIN Rail Installation

Hook the upper retention slots of the enclosure chassis over the top flange of standard 35 mm DIN tracking. Rotate the lower portion of the housing down until the spring-loaded lower locking mechanisms snap firmly around the base metal rail.

Terminal Base Seating

Align the molded structural alignment channels on the underside of the electronic module with the guide rails on the pre-installed terminal base unit. Push the module directly into the socket until the edge latches click to secure the unit.

Wiring Configuration

Connect external sourcing sensors to terminals 0 through 7. Ensure that the 24V DC external operational voltage loop supplies field devices from the corresponding power rail on the terminal block to maintain a proper common return path.

Signal Integrity and Routing

Isolate the low-voltage direct current input lines from high-voltage AC electrical lines, electric motor feeds, and inductive switching fields to prevent ambient electromagnetic noise from generating false input transitions.

FAQ

What is the electrical switching configuration of this module?

The module uses a sinking configuration, which requires connected field devices to source current into the input terminal.

Are individual input channels electrically isolated from each other?

No, the eight input channels share a common internal ground reference rail within the module assembly.

Can an engineer hot-swap this device during active plant operation?

Yes, it supports removal and insertion under power, allowing for module replacement without shutting down power to the wider assembly.

What terminal base models can be used to mount this unit?

It is compatible with standard terminal base assemblies including the 1794-TB2, 1794-TB3, 1794-TB3S, and 1794-TBN units.

How can high-frequency signal bounce from a mechanical switch be prevented?

The digital input filter time can be adjusted in the controller configuration parameters to stabilize noisy field signals.

What do the yellow LED indicators on the faceplate signify?

Each indicator lights up when the corresponding input channel senses an active on-state voltage parameter.

Does the module require external power to operate?

Yes, a nominal 24V DC power source must be run to the terminal base block to drive the internal field-side input circuitry.

What voltage constitutes a logical off-state for a channel?

An input channel registers as off when the voltage potential drops below 5.0V DC or the input loop current falls below 1.5 mA.

Can this device process signals from 120V AC limit switches?

No, this module is rated exclusively for low-voltage direct current ranges between 10V DC and 31.2V DC.

How is input data sent from this module to a ControlLogix processor?

The unit transmits register values across the local FlexBus backplane to a network adapter module, which then forwards the data to the central controller.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...