1 от 3

Bently Nevada 140734-02 3500/42M Proximitor®/Seismic Monitor

Bently Nevada 140734-02 3500/42M Proximitor®/Seismic Monitor

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/42M 140734-02

  • Country of origin:Съединени щати

  • Product Type: Proximitor/Seismic Monitor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 910g

  • Dimensions: 241.3 mm x 24.4 mm x 241.8 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Description

The 3500/42M, designated under spare component assembly 140734-02, is a four-channel machinery protection hardware instrument designed to process inputs from proximity and seismic transducers. The module acts as an analytical safety layer within the 3500 Machinery Protection System, conditioning analog wave inputs to calculate variables such as radial vibration, thrust position, eccentricity, or velocity, and executing comparisons against user-programmable alarm setpoints. Programmed in paired channel groups through the 3500 Rack Configuration Software, it drives automated alarms when configured safety limits are violated. The hardware supplies individual +4 to +20 mA current recorder loops for each channel to transmit real-time static values directly to distributed control networks and operational archiving servers without interrupting primary protective operations.

Features

  • Four independent processing channels supporting multiple concurrent vibration and positional function types.
  • Flexible transducer matching accommodating standard eddy current proximity probes, accelerometers, and velocity sensors.
  • Pairwise channel programming architectures permitting distinct mathematical operations across channel pairs 1-2 and 3-4.
  • Configurable Alert and Danger setpoint assignment supporting granular machine safety limits across all calculated static values.
  • Individual, front-panel coaxial buffered transducer connections engineered with short-circuit protection for structural diagnostics.

Applications

  • Industrial steam turbine rotor shaft radial vibration tracking and thrust position observation.
  • Large-scale centrifugal gas compressor casing seismic velocity monitoring and mechanical trip protection.
  • Power generation gas turbine shaft absolute vibration and rotor eccentricity monitoring.
  • Heavy industrial fluid pump rolling element bearing health analysis using specialized REBAM logic.

Ordering Information

Option Code Description
3500/42-AXX-BXX Proximitor® Seismic Monitor
A: I/O Module Type  
01 Prox/Seismic I/O Module with Internal Terminations
02 Prox/Seismic I/O Module with External Terminations
03 TMR Prox/Seismic I/O Module
04 I/O Module with Internal Barriers (4 x prox./accel. ch's) and Internal Terminations
05 I/O Module with Internal Barriers (2 x prox./accl. + 2 x Velomitor® channels) and Internal Terminations
06 I/O Module with Internal Barriers (4 x Velomitor® channels) and Internal Terminations
07 Shaft Absolute I/O Module with Internal Terminations
08 Shaft Absolute I/O Module with External Terminations
09 Prox/Velom I/O Module with Internal Terminations
10 Prox/Velom I/O Module with External Terminations
B: Agency Approval Option  
00 None
01 CSA/NRTL/C (Class 1, Div 2)
02 ATEX/CSA (Class 1, Zone 2)
Spares  
140734-02 3500/42M Proximitor®/Seismic Monitor

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 3500/42M
Part Number 140734-02
Signal Inputs Accepts 1 to 4 proximity, velocity, or acceleration transducer signals 
Standard Input Impedance 10 kΩ for Proximitor and Acceleration inputs 
Bussed TMR Input Impedance 50 kΩ effective impedance with 3 channels wired in parallel 
Nominal Power Consumption 7.7 Watts typical 
Front Panel Status Indicators OK LED, TX/RX LED, Bypass LED 
Buffered Output Ports 4 short-circuit protected coaxial connectors (1 per channel) 
Buffered Output Impedance 550 Ω 
Transducer Power Supply -24 Vdc 
Recorder Current Output +4 to +20 mA DC individual loop per channel 
Recorder Voltage Compliance 0 to +12 Vdc range across load 
Recorder Load Resistance Range 0 to 600 Ω 
Analog Bit Resolution 0.3662 µA per bit 
Data Update Rate 100 ms or less 
Thrust/Diff. Expansion Filter Direct filter: -3 dB at 1.2 Hz | Gap filter: -3 dB at 0.41 Hz 
Static Value Accuracy Within ±0.33% of full-scale typical, ±1% maximum 
Alarm Setpoint Accuracy Within 0.13% of the desired value 
Alert Alarm Delay Scope 1 to 60 seconds in 1 second intervals 
Danger Alarm Delay Scope 0.1 seconds or 1 to 60 seconds in 0.5 second intervals 
Operating Temp (Standard I/O) -30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit) 
Operating Temp (Barrier I/O) 0 Celsius to +65 Celsius (32 Fahrenheit to +150 Fahrenheit) 
Storage Temperature Limits -40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit) 
Operating Humidity Bounds 95% noncondensing relative humidity 
Monitor Module Weight 0.91 kg (2.0 lbs) 
I/O Module Weight (Non-barrier) 0.20 kg (0.44 lbs) 
I/O Module Weight (Barrier) 0.46 kg (1.01 lbs) 
Monitor Module Dimensions 241.3 mm x 24.4 mm x 241.8 mm 
I/O Module Dimensions (Standard) 241.3 mm x 24.4 mm x 91.1 mm 
I/O Module Dimensions (Barrier) 241.3 mm x 24.4 mm x 163.1 mm 
Rack Allocation Footprint 1 full-height front slot and 1 full-height rear slot 

Connections/Interfaces

Terminal / Connector Pin Function
Front Panel Coaxial Connectors Short-circuit protected buffered output for dynamic signal diagnostics 
Prox/Seismic I/O Terminals Rear interface wire blocks for direct internal termination sensor hookups 
External Termination Headers Dedicated multi-pin headers interfacing to standalone terminal blocks 
Recorder Outputs Dedicated loop connection points for +4 to +20 mA proportional telemetry 

Installation Guidelines

  • Noise Suppression: Ensure sensor shielding parameters are thoroughly maintained by tying instrumentation ground wires to the specified chassis ground points on the I/O block to limit electromagnetic coupling.
  • Alignment Mapping: Confirm that the main card assembly 140734-02 slides cleanly along the guide tracks of the front rack slot, seating firmly into the rear data backplane lines.
  • Termination Rules: Never mix external termination blocks with I/O modules explicitly designed and coded for internal termination applications.
  • Space Allotment: Maintain clear tracking lines on both the forward and rear margins of the chassis rack frame to promote unrestricted ambient airflow through the module housings.

Compliance and Certifications

  • CE Low-Voltage Directives: EN61010-01 safety requirements for industrial monitoring equipment.
  • EMC Emissions Shielding: Certified under IEC/EN 61000-6-4 and EN 55011 Class A standards.
  • EMC Susceptibility Criteria: Meets EN 61000-4-2 Electrostatic Discharge (Criteria B) and EN 61000-4-3 Radiated Susceptibility (Criteria A).
  • Hazardous Area Approvals: CSA/NRTL/C Class I, Division 2, Groups A, B, C, D (T4 rating at Ta = -30 Celsius to +65 Celsius).

Technical & Procurement FAQ

Q: Can this component function as an absolute overspeed machinery shutdown mechanism?

A: No, this device is explicitly designed to handle dynamic proximitor and seismic acceleration/velocity metrics rather than the high-frequency speed wheel edge triggers needed for deterministic overspeed protection loops.

Q: What is the underlying distinction between the 3500/42M designation and part number 140734-02? A: The 3500/42M reflects the official overall functional system monitor series classification, whereas the code 140734-02 governs the exact ordering catalog number for the internal replacement main circuit board.

Q: Will an unexpected short circuit across the +4 to +20 mA recorder loop disrupt machinery protection? A: No, the analog current loop circuitry is internally isolated, meaning the processing logic, monitor functionality, and protective safety alarms continue operating normally if a field recorder loop shorts.

Q: Is it possible to program channel 1 to calculate radial vibration while channel 2 evaluates thrust position? A: No, monitoring channels are configured software-wise in distinct functional pairs, meaning channels 1 and 2 must execute the same baseline behavioral function, while channels 3 and 4 can handle another.

Q: What happens to the front panel indicators if the module experiences an internal processing error? A: The green OK LED will drop out of its constant illuminating status, signaling a hardware exception condition and initiating a safe system bypass state to avoid false over-limit trips.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 140734-02 3500/42M Proximitor®/Seismic Monitor

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял Сребърен
Country of origin
Съединени щати
Power source
Постоянен ток

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...