1 от 3

Bently Nevada 3300/45 Dual Differential Expansion Monitor

Bently Nevada 3300/45 Dual Differential Expansion Monitor

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3300/45

  • Country of origin:Съединени щати

  • Product Type: Dual Differential Expansion Monitor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Dimensions: 15cm x 10cm x 5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

The Bently Nevada 3300/45 Dual-Channel Differential Expansion Monitor is a dual-channel monitor designed for the legacy Bently Nevada 3300 Monitoring System.
It is specifically engineered to measure Differential Expansion, defined as the relative axial movement between the turbine shaft and the casing.

This parameter is critical for large steam turbines during startup and shutdown, where thermal expansion rates differ between rotating and stationary components. Accurate monitoring helps prevent rotor-to-casing contact, mechanical stress, and potential turbine damage.


Technical Specifications

1. Input & Signal Processing

Transducer Input
Accepts signals from non-contacting proximity probes, including:

  • 8 mm Proximitor System

  • 11 mm Proximitor System

  • 25 mm Proximitor System

  • 50 mm Proximitor System

Measurement Modes

The monitor supports multiple configuration methods depending on the mechanical design:

Standard Single Composite

  • Uses one probe to measure a tapered collar or ramp surface

  • Common in compact turbine designs

Dual Complementary

  • Uses two probes to increase measurement linearity

  • Provides redundancy for critical protection systems

Accuracy

  • ±0.33% of full-scale (typical)

  • Reference temperature:
    +25°C (+77°F)


2. Outputs

Recorder Outputs

User-programmable signal formats:

  • +4 to +20 mA

  • 0 to -10 Vdc

  • +1 to +5 Vdc

Buffered Outputs

  • Front panel: Coaxial connectors

  • Rear panel: Terminal block connections

  • One output per channel

Output Impedance

  • 100 Ω


3. Alarms & Display

Display

  • Dual vertical bargraph LCD indicators

  • Real-time differential expansion visualization

Alarm Setpoints

Bi-directional alarm configuration:

  • Alert Alarm

  • Danger Alarm

  • Digitally adjustable thresholds

OK Indicator

The OK LED monitors the health status of:

  • Monitor electronics

  • Connected transducers

  • Field wiring integrity


Ordering Information

Order Format

3300/45-AXX-BXX-CXX-DXX-EXX

A — Full-Scale Range Option

Code Measurement Range
01 0.1-0-0.1 inches
02 0.2-0-0.2 inches
03 0.3-0-0.3 inches
04 0.4-0-0-0.4 inches
11 2.0-0-2.0 mm
12 4.0-0-4.0 mm
13 8.0-0-8.0 mm
14 10-0-10 mm

B — Transducer Input Option

Code Compatible Proximitor System
01 8 mm or 11 mm (200 or 100 mV/mil)
02 25 mm (50 mV/mil)
03 50 mm (25 mV/mil)
04 7200 14 mm (100 mV/mil)

C — Alarm Relay Option

Code Description
00 No relays
01 Epoxy-sealed relay
02 Hermetically-sealed relay
03 Quad relay (Epoxy-sealed only)

D — Agency Approval Option

Code Certification
00 Not required
01 CSA / NRTL / C
02 ATEX self-certification

E — Safety Barrier Option

Code Description
00 None
01 External barrier
02 Internal barrier

Engineering & Installation Guide

Tapered Collar Configuration

When a single probe is installed on a tapered collar:

  • The collar angle must be accurately configured in the monitor

  • This ensures correct linear conversion from displacement to expansion

Incorrect angle configuration will directly affect measurement accuracy.


Cold vs. Hot Zero Reference

Differential expansion monitoring follows a standard baseline method:

Cold condition:

  • The system is zeroed during machine startup

  • Shaft and casing temperatures are stable

Hot condition:

  • The monitor tracks expansion as thermal growth occurs

  • Real-time displacement is calculated relative to the cold reference

This method is standard practice for steam turbine protection systems.


Relay Voting Strategy (Recommended for Critical Turbines)

For high-integrity protection systems:

AND voting logic (2-out-of-2) is recommended.

This configuration ensures:

  • A single probe failure will not trigger a false trip

  • Both channels must confirm an alarm condition

This approach is widely used in turbine protection architectures.


Probe Linearity Considerations

Large-range proximity probes require precise mechanical setup.

Important differences:

25 mm and 50 mm probes

  • Have a wider measurement range

  • Require specific initial gap settings

  • Exhibit different linear regions compared to standard 8 mm probes

Improper probe gapping may result in:

  • Reduced measurement accuracy

  • Non-linear output response

  • False alarm conditions

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Сиво-бял
Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...