Honeywell 05701-A-0327 System 57 Double SPCO Relay Card

Honeywell 05701-A-0327 System 57 Double SPCO Relay Card

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 05701-A-0327

  • Country of origin:Съединени щати

  • Product Type: Relay Interface Cards

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 112mm x 25mm x 102mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Количество
Покажи пълните подробности

Honeywell 05701-A-0327 System 57 Double SPCO Relay Card

Description

The Honeywell 05701-A-0327 is a plug-in interface and control loop module designed for the System 57 / 5701 Series Control System. This hardware module functions primarily as an electrical bridge providing connections between field-mounted industrial gas sensors and their designated Single Channel Control Cards. By decoupling the continuous gas display and processor logic from physical field wiring, the card secures high loop integrity across individual monitoring nodes.

In addition to routing standard sensor signaling paths, the module features single-pole change-over (SPCO) electromechanical relays that provide voltage-free contact outputs to drive external alarm indicators or protective shutdown systems. These integrated relay contacts are permanently or field-configured to monitor specific hazard indices, continuously operating across discrete thresholds for the A1 alarm level, A2 alarm level, and local fault condition paths. The physical layout is optimized for high-density DIN-rail rack assemblies with a dual-chamber separation design providing native attenuation of localized electromagnetic anomalies.

Features

  • Houses high-reliability single-pole change-over (SPCO) relays delivering secure voltage-free contact outputs directly to external field infrastructure.
  • Processes individual signal loops for three distinct tracking criteria: A1 alarm, A2 alarm, and fault condition states.
  • Incorporates an integrated ground termination pathway to facilitate clean cable shield drainage directly inside the sub-rack housing.
  • Formed in a compact 3U Eurocard format factor, permitting seamless slot installation without modifying the existing backplane power bus.
  • Built with independent terminal blocks mapping clearly labeled user references for both front and rear sub-rack access configurations.

Applications

  • Distributed gas monitoring arrays requiring physical contact replication for localized A1 and A2 hazard sirens or warning strobe beams.
  • Interface termination matrices in industrial marshaling cabinets that bridge analog safety metrics to remote PLC or DCS monitoring systems.
  • Dedicated control loops processing low-voltage field safety signals across oil and gas production environments or water treatment facilities.

Technical Specifications

Parameter Specifications
Manufacturer Honeywell
Model Number 05701-A-0327
Product Type Double SPCO Relay Card
Product Series System 57 / 5701 Series Control System
Contact Architecture Single Pole Change-Over (SPCO)
Relay Signal Paths A1 Alarm, A2 Alarm, Fault Condition
Max AC Relay Fusing 5A maximum (when switching mains AC voltages)
Height 112mm
Width 25mm
Depth 102mm
Shipping Weight 2 Kg

Connections/Interfaces

Connector Pin Function
TB1 - PSU (+) Main External 24V DC Power Supply Unit Positive Termination Input
TB1 - PSU (-) Main External 24V DC Power Supply Unit Negative Common Reference
TB1 - AUX (+) Standby Backup Battery Storage Power Supply Positive Termination Input
TB1 - AUX (-) Standby Backup Battery Storage Power Supply Negative Common Reference
TB1 - GND Low-Impedance Dedicated Instrumentation Clean Earth Shield Connection

Rear Access Connections

User Terminal Reference Connector Pin / Function
Ground 26 / Shield Ground Path
Sensor S Connection 25 / Sensor Supply line
Sensor NS Connection 27 / Non-Sink / Signal return line
Sensor 01 Connection 28 / Sensor 0V reference line
Analogue O/P (+) 29 / Isolated Current Loop Output Positive
Analogue O/P (-) 32 / Isolated Current Loop Output Negative
Remote Inhibit In 31 / External Channel Inhibit Signal
Remote Reset In 34 / External Alarm Reset Command Line
+24V (Out/In) 33 / System 24V DC auxiliary line
0V (Out/In) 36 / System 0V DC auxiliary common
Fault NC 1 / Fault Relay Normally Closed Terminal
Fault NO 2 / Fault Relay Normally Open Terminal
Fault COM 3 / Fault Relay Common Path
A1(1) NC 7 / A1 Alarm Normally Closed Contact
A1(1) NO 8 / A1 Alarm Normally Open Contact
A1(1) COM 9 / A1 Alarm Common Path
A2(1) NC 11 / A2 Alarm Normally Closed Contact
A2(1) NO 12 / A2 Alarm Normally Open Contact
A2(1) COM 10 / A2 Alarm Common Path

Front Access Connections

User Terminal Reference Connector Pin / Function
0V (Out/In) 36 / System 0V DC auxiliary common
+24V (Out/In) 35 / System 24V DC auxiliary line
Remote Reset In 34 / External Alarm Reset Command Line
Remote Inhibit In 33 / External Channel Inhibit Signal
Analogue O/P (-) 32 / Isolated Current Loop Output Negative
Analogue O/P (+) 31 / Isolated Current Loop Output Positive
Sensor 01 Connection 30 / Sensor 0V reference line
Sensor NS Connection 29 / Non-Sink / Signal return line
Ground 28 / Shield Ground Path
Sensor S Connection 27 / Sensor Supply line
Ground 26 / Alternative Shield Ground Terminal
Ground 25 / Alternative Shield Ground Terminal
Fault NC 1 / Fault Relay Normally Closed Terminal
Fault NO 2 / Fault Relay Normally Open Terminal
Fault COM 3 / Fault Relay Common Path
A1(1) NC 5 / A1 Alarm Normally Closed Contact
A1(1) NO 8 / A1 Alarm Normally Open Contact
A1(1) COM 9 / A1 Alarm Common Path
A2(1) NC 11 / A2 Alarm Normally Closed Contact
A2(1) NO 12 / A2 Alarm Normally Open Contact
A2(1) COM 10 / A2 Alarm Common Path

Installation Guidelines

  • Mains Switching Safety: When introducing mains AC infrastructure across the relay terminals, verify that the external AC supply lines are strictly restricted with a 5A maximum fuse rating.
  • Protective Earth Grounding: A high-integrity safety earth connection must be terminated directly onto the dedicated ground stud terminal of the relay card whenever high-voltage lines are routed to the contacts.
  • Cable Routing Separation: Isolate all control relay contact wiring fields from high-sensitivity sensor signal lines to avoid inducing parasitic voltage noise across precision measuring paths.
  • Single-End Shield Termination: For field-mounted gas detectors anchored to local earth studs or steel structures, terminate the cable screen sheath exclusively at one end (either at the sensor body or at the relay interface card) to prevent hazardous ground loop fields.
  • Hot-Swap Interlocks: Individual channel control cards can be removed from the front side of the sub-rack without disturbing the active field or relay wiring connected at the rear interface terminals.

FAQ

  • How are the contact orientations of the A1 and A2 alarm relays defined? 

    The documented terminal descriptions for normally closed (NC) and normally open (NO) states match the completely de-energized, unpowered condition of the control module.

  • What is the default operation mode of the onboard FAULT relay circuit? 

    The FAULT relay is hardwired for normally energized operation during normal, non-fault plant conditions, ensuring that a total drop in control loop power triggers a fail-safe system alarm state.

  • Can the alarm relay actuation modes be altered to fit normally energized logic?

     Yes, the A1 and A2 alarm relays can be individually reconfigured for normally energized or normally de-energised operation by executing setup updates via the central Engineering Interface Software.

  • Does this interface module accept thicker high-current industrial wires? 

    The mechanical compression terminals populated on the interface card assembly are rated to accept single-stranded or multi-stranded instrumentation cables up to a maximum cross-sectional area of 2.5mm2.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 05701-A-0327 System 57 Double SPCO Relay Card

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Color pattern
Зелен
Country of origin
Съединени щати

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...