Operating as an intrinsically safe solenoid driver, the Weidmuller ACT20X-SDI-HDO-H-S controls valve systems, acoustic alarms, and indicators located in hazardous areas. This high-performance module provides galvanic isolation between the control system and the field devices, ensuring reliable signal transmission and robust explosion protection in demanding process environments.

Key Features

  • Intrinsically safe output (Ex ia IIC) designed for direct deployment in hazardous areas.
  • Integrated alarm relay output for immediate signaling of power loss or internal device errors.
  • FDT/DTM software-based configuration for precise parameterization and diagnostic monitoring.
  • Compact 22.5 mm DIN-rail housing to optimize space within electrical control panels.
  • Secure screw connection technology to guarantee long-term, vibration-resistant wiring.

Industrial Applications

  • Chemical and petrochemical processing plants with explosive atmospheres (Zone 0, 1, and 2).
  • Oil and gas extraction, refining, and distribution facilities.
  • Pneumatic and hydraulic solenoid valve control in hazardous process loops.
  • Industrial signaling, beacon control, and acoustic alarm integration.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Weidmuller
Article Number (SKU) 8965410000
Model Designation ACT20X-SDI-HDO-H-S
Product Type Valve Control / Solenoid Driver
Number of Channels 1
Supply Voltage Range 19.2 to 31.2 V DC
Power Consumption <= 2.5 W
Step Response Time <= 10 ms
Alarm Functionality No supply voltage, Device error
Alarm Relay Output 1 NC contact
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current (Alarm) <= 0.5 A AC / 0.3 A DC
Configuration Interface FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Temperature -20 to +60 degC
Ambient Humidity 0 to 95% (non-condensing)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Net Weight 170 g
Shipping Weight (Calculated) 1.2 kg
Country of Origin Germany

Connections and Interfaces

Terminal Block / Pin Functional Assignment
Terminals 11, 12 Digital Control Input (Safe Area)
Terminals 13, 14 Alarm Relay Output (NC Contact)
Terminals 41, 42 Intrinsically Safe Solenoid Output (Hazardous Area, Ex ia)
Terminals 51, 52 Power Supply Input (19.2 to 31.2 V DC)

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-SDI-HDO-H-S is fully compatible with standard FDT/DTM frame applications such as Weidmuller WI-Manager. When replacing legacy ACT20X models, ensure that the configuration profile is exported and reloaded using the CBX200 USB interface cable to preserve specific safety loop parameters.

Application Pitfalls & Engineering Notes

When mounting multiple ACT20X modules side-by-side on a DIN rail, ensure cabinet ventilation maintains ambient temperatures below 60 degC. High-density packing without adequate airflow can lead to localized thermal stress. Always verify that the Ex-i output parameters (Uo, Io, Po) strictly match the electrical characteristics of the connected solenoid valve to maintain safety loop integrity.

Commissioning & Wiring Tips

Perform offline configuration via the front-panel port before mounting the unit onto the DIN rail. Ensure that intrinsically safe field wiring (hazardous area) is physically separated from non-intrinsically safe wiring (safe area) by a minimum distance of 50 mm, or utilize physical partitions in compliance with IEC/EN 60079-14 standards.

Installation Guidelines

CRITICAL WARNING:

Isolate all power sources before mounting, wiring, or configuring the device. Failure to de-energize the system prior to installation in hazardous areas can result in electrical arcing, leading to severe equipment damage, explosion, or personal injury.

1 Mount the module vertically onto a standard TS 35 DIN rail, ensuring secure mechanical latching.
2 Connect the intrinsically safe field device wiring to the Ex-designated terminals (Terminals 41 and 42).
3 Wire the control input, alarm relay, and the 24 V DC power supply to the safe-area terminals.
4 Connect the CBX200 USB cable to configure the alarm thresholds and operational parameters via FDT/DTM software.

How is the ACT20X-SDI-HDO-H-S module configured?

Configuration is performed using standard FDT/DTM software via a CBX200 USB interface cable connected to the front-panel port.

What is the purpose of the integrated alarm relay?

The alarm relay provides a normally closed (NC) contact that opens to signal a loss of supply voltage or an internal device error.

Can this module drive solenoid valves located in Zone 0?

Yes, the output circuit is rated intrinsically safe (Ex ia IIC), allowing direct connection to solenoid valves and indicators in Zone 0, 1, or 2.

What are the maximum switching limits for the alarm contact?

The alarm relay contact supports up to 125 V AC at 0.5 A or 110 V DC at 0.3 A.

Глобална експресна доставка

  • Стандартна доставка: 4-6 работни дни чрез DHL, FedEx и UPS.
  • Експресна изпращане: Изпращане в същия ден за налични поръчки, направени преди 14:00 ч. (GMT+8).
  • Глобално покритие: Обслужваме над 150 държави, включително бърза доставка до Саудитска Арабия и ОАЕ.

Връщания и гаранция

  • 30-дневна гаранция: Връщания се приемат за налични продукти в оригинална, фабрично запечатана опаковка.
  • 12-месечна гаранция: Всеки индустриален компонент е подкрепен с нашата професионална техническа гаранция.

Поръчките се обработват и доставят от понеделник до петък (с изключение на официалните празници).


За пълна информация относно допустимост, такси за презареждане и международни връщания, моля, разгледайте нашия официален Политика за възстановяване и връщане .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Наскоро разгледани продукти

Технически знания

Електрически задвижващи механизми, проектирани да заменят хидравлични и пневматични системи: Практическо ръководство за индустриална автоматизация

Тази статия обяснява как интегрираните електрически задвижвания, като серията e-Actuator на SMC, трансформират индустриалното управление на движението, като заменят традиционните пневматични и...

Математически операции с OpenPLC за индустриални автоматизационни приложения

Тази статия обяснява как PLC системите изпълняват основни математически операции като събиране, изваждане, умножение, деление, модуло и степенуване в индустриалната автоматизация. Показва как тези...

Разширена булева логика с FBD PLC програмиране: Практически индустриални приложения отвъд основната логика

Статията обяснява няколко усъвършенствани булеви логически функции, използвани в програмирането на PLC, извън основните операции AND, OR и NOT. Тя разглежда как инструменти като таблици на...

Булева логика в програмирането на PLC: Разбиране на логическите врати в FBD

Булевата логика е основата на всяка програма за PLC. От прости машинни управления до сложни индустриални автоматизационни системи, логическите врати определят как контролерите реагират на променящите...

Подробно ръководство за индустриални защитни стени и сегментиране на OT мрежи

Индустриалните защитни стени играят ключова роля в киберсигурността на OT, като защитават мрежите PLC, DCS и SCADA чрез сегментация, контрол на входящия/изходящия трафик и интеграция на IDS/IPS в...

Ръководство за роботизирани захвати: от деликатно боравене до тежка автоматизация

Съвременните роботизирани захвати се развиват отвъд традиционните механични челюсти. От системи с лепкави повърхности, вдъхновени от геконите, и меки захвати за хранителни продукти до инструменти за...