ABB S202-K4 2CDS252001R0337 S200 Miniature Circuit Breaker

ABB S202-K4 2CDS252001R0337 S200 Miniature Circuit Breaker

  • Manufacturer: ABB

  • Product No.: S202-K4 2CDS252001R0337

  • Country of origin:Germany

  • Product Type: Miniature Circuit Breaker

  • Payment: T/T, Western Union

  • Weight: 224g

  • Dimensions: 69 mm x 88 mm x 35 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The S202-K4 electrical assembly with Product ID 2CDS252001R0337 is a current-limiting 2-pole miniature circuit breaker designed for overcurrent and short-circuit fault management in power distribution networks. This device incorporates two alternative activation mechanisms: a delayed thermal tripping mechanism for targeted overload protection and an electromechanical magnetic tripping mechanism for rapid short-circuit mitigation. Built within the S200 product range, it features a K-characteristic curve optimized to safeguard circuitry while handling inductive current inrushes without nuisance tripping. It is suitable for deployment across residential, commercial, and diverse industrial infrastructure applications.

Features

  • Incorporates a dual-pole mechanical assembly for isolated multi-line electrical protection.
  • Configured with a K-type tripping characteristic curve to manage targeted motor and inductive high-inrush currents.
  • Provides dual thermal-magnetic functions protecting against sustained overloads and short-circuit events.
  • Employs a current-limiting design to restrict electrical fault energy passing through the downstream circuit.
  • Features a Failsafe Bidirectional Cylinder-lift Terminal configuration for verified wiring connections.
  • Outfitted with a toggle actuator showing a clear Red ON/Green OFF contact position indication.

Applications

  • Protection of industrial inductive motor branch networks and machinery loads.
  • Low-voltage commercial electrical panel assemblies and power distribution layouts.
  • Residential branch sub-circuits demanding specialized high-inrush overcurrent protection.

Ordering Information

Parameter Value
Extended Product Type S202-K4
Product ID 2CDS252001R0337
EAN 4016779507363
Package Level 1 Units carton 5 piece

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 2CDS252001R0337
Extended Product Type S202-K4
Catalog Description Miniature Circuit Breaker-S200-2P-4A-K-(AC) 6 KA
Number of Protected Poles 2
Number of Poles 2P
Tripping Characteristic K
Rated Current (In) 4 A
Input Voltage Type AC/DC
Rated Operational Voltage acc. to IEC 60947-2 440 V AC
Rated Frequency (f) 50 / 60 Hz
Rated Short-Circuit Capacity (AC) 6 kA, (DC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 20 kA, (400 V AC) 10 kA, (440 V AC) 10 kA
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 15 kA, (400 V AC) 7.5 kA, (440 V AC) 7.5 kA
Rated Insulation Voltage (Ui) acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp) 4 kV
Power Loss 3.4 W (at Rated Operating Conditions per Pole 1.7 W)
Energy Limiting Class 3
Electrical Endurance 20000 AC cycle
Mechanical Endurance 20000 cycle
Housing Material Insulation Group II, RAL 7035
Degree of Protection IP20, IP40 (Enclosure with Cover IP40)
Pollution Degree 3
Ambient Air Temperature Operation -25 ... +55 degC, Storage -40 ... +70 degC
Width in Number of Modular Spacings 2
Product Net Width 35 mm
Product Net Height 88 mm
Product Net Depth / Length 69 mm
Product Net Weight 0.224 kg

Installation Guidelines

  • DIN Rail Installation: Mount directly onto TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) mounting rails according to IEC 60715 regulations.
  • Mounting Position: Accommodates any physical layout orientation during panel installation.
  • Terminal Wiring: Strip wire connections to a length of 12.5 mm and tighten using a Pozidriv 2 screwdriver to a target torque specification of 2.8 N-m.
  • Power Supply Connection: Arbitrary power connection interface configuration is fully supported.

Compliance and Certifications

  • Declaration of Conformity - CE: 2CDK403001D0607
  • Declaration of Conformity - UKCA: 9AKK108467A5053
  • Certification Agencies: EN, IEC, UL
  • Standards: IEC/EN 60898-1, IEC/EN 60947-2, UL 1077

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB S202-K4 2CDS252001R0337 S200 Miniature Circuit Breaker

What is the function of the dual tripping mechanisms in the device?

The device features a delayed thermal tripping mechanism to manage overload parameters and an electromechanical magnetic mechanism for short-circuit protection.

What is the specific torque specification required for terminal installation?

The terminal connections should be secured using a tightening torque value of 2.8 N-m.

Does the device support arbitrary power supply entry?

Yes, the power supply connection orientation on the device is completely arbitrary.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...