The 1768-ENBT is a CompactLogix EtherNet/IP Communication Module developed by Allen-Bradley to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.

Features

  • Provides automated data management over EtherNet/IP networks to reduce packet collisions and sustain optimal bandwidth.
  • Features an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.
  • Supports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.
  • Implements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.
  • Interfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I/O modules.

Applications

  • Distributed industrial automation and manufacturing plant network management.
  • Inter-controller data synchronization across multiple Logix5000 systems.
  • SCADA network routing and remote control system interface integration.

Technical Specifications

Parameter Specification
Backplane Current 834 mA at 5.2V DC
Power Consumption 4.34 W
Power Dissipation 4.38 W
Isolation Voltage 30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)
Wire Size RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wiring Category 2 - on communication ports
North American Temp Code T4A
IEC Temp Code T4
Mounting Screw Torque 1.16 N.m (10 lb.in) using M4 or #8 screws
Dimensions (HxWxD), Approx. 132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)
Weight, Approx. 0.213 kg (7.5 oz)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 5 g @ 10...500 Hz
Operating Shock 30 g
Nonoperating Shock 50 g
Emissions CISPR 11 Group 1, Class A
Enclosure Type Rating None (open-style)

Connections/Interfaces

Connector Pin Function
Pin 1 TD+ (Transmit Data +)
Pin 2 TD- (Transmit Data -)
Pin 3 RD+ (Receive Data +)
Pin 4 NC (No Connection)
Pin 5 NC (No Connection)
Pin 6 RD- (Receive Data -)
Pin 7 NC (No Connection)
Pin 8 NC (No Connection)

Installation Guidelines

  • Plan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.
  • Ensure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.
  • Secure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.
  • If choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.
  • Connect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.
  • Never connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.
  • Always wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.
  • Mitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.

Compliance and Certifications

  • c-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)
  • c-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)
  • CE Certified (European Union 2004/108/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)
  • C-Tick Compliant (Australian Radiocommunications Act, compliant with AS/NZS CISPR 11)
  • Ex Certified (European Union 94/9/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)
  • EtherNet/IP ODVA Conformance Tested

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

What does a flashing red status on the NET indicator signify?

A flashing red network (NET) indicator indicates that one or more of the established connections in which the communication module is acting as the target device have timed out.

Why must installers wait for all status lights to turn off before separating the hardware?

When system power is switched off, the main controller writes its active project data to non-volatile memory. Separating the modules before all status lights turn off interrupts this process, resulting in the unrecoverable loss of the control program.

What happens if the OK status indicator exhibits a flashing red and green pattern?

A flashing red and green pattern on the OK indicator indicates that the communication module is actively executing its standard power-up self-test routines.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...