1 z 1

BECKHOFF BK2000 Lightbus Bus Coupler

BECKHOFF BK2000 Lightbus Bus Coupler

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: BK2000

  • Country of origin:Germany

  • Product Type: Lightbus Bus Couplers

  • Payment: T/T, Western Union

  • Weight: 150g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Engineered for deterministic communication in high-interference environments, the BECKHOFF BK2000 Lightbus Bus Coupler serves as the decentralized interface between the fiber-optic Lightbus system and modular Beckhoff Bus Terminals. This unit automatically configures and maps the digital, analog, and specialty process signals from up to 64 connected I/O terminals directly into the control system's memory. By using fiber-optic transmission media, the module ensures complete electrical isolation, high noise immunity, and rapid data exchange rates of 2.5 MBaud. This configuration makes it highly suitable for complex, geographically distributed control architectures where electrical noise and ground loops are common concerns.

Features

  • Integrates a specialized Lightbus fiber-optic interface for high-speed, noise-free industrial communication.
  • Supports the direct connection of up to 64 Beckhoff Bus Terminals to a single node.
  • Provides an internal K-bus output current of up to 1.75 A to power connected I/O terminal logic.
  • Equipped with an integrated configuration interface compatible with the KS2000 software tool.
  • Features integrated, isolated 24 V DC power contacts for reliable peripheral power distribution.
  • Robust IP20-rated housing with a compact DIN-rail mounting profile.

Applications

  • Distributed control networks in high-voltage and power-generation facilities.
  • Automotive assembly lines prone to high electromagnetic welding interference.
  • Water and wastewater treatment facility telemetry.
  • Heavy machinery and packaging systems requiring robust, isolated I/O nodes.

Technical Specifications

Parameter Value
Manufacturer BECKHOFF
Part Number/Model BK2000
Product Type Lightbus Bus Coupler
Communication Protocol Lightbus (fiber-optic)
Baud Rate 2.5 MBaud
Supply Voltage 24 V DC (+/- 10%)
Input Current 105 mA typical, 900 mA maximum
K-bus Output Current 1.75 A maximum
Supply Isolation 500 Veff (K-bus / supply voltage)
Max. Number of Bus Terminals 64
Digital Peripheral Signals 256 inputs and outputs
Analog Peripheral Signals 128 inputs and outputs
Peripheral Process Image 512 input bytes, 512 output bytes
Configuration Port KS2000 configuration interface
Power Contacts Voltage 24 V DC / AC
Power Contacts Current Load 10 A maximum
Max. Voltage Capacity 500 Veff (power contact / supply voltage)
Housing Protection Rating IP20
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Relative Humidity 95% non-condensing
Vibration / Shock Resistance According to IEC 68-2-6 / IEC 68-2-27
EMC Immunity (Burst / ESD) According to EN 61000-4-4 / EN 61000-4-2
Mounting Orientation Any orientation
Weight Approx. 150 g

Installation Guidelines

  • Mount the coupler onto a standard 35 mm DIN rail (EN 60715) by snapping it into place until secure.
  • Ensure the system is completely de-energized before connecting the 24 V DC control power or peripheral wiring.
  • Observe minimum bending radii for all connected Lightbus fiber-optic cables to avoid signal attenuation or physical damage.
  • Keep the ventilation slots on the top and bottom of the housing clear of obstructions to facilitate proper thermal convection.
  • Verify that the total current draw of all connected Bus Terminals does not exceed the maximum 1.75 A K-bus current limit. Use power feed terminals if necessary.

Compliance and Certifications

  • CE
  • IEC 68-2-6 (Vibration Resistance)
  • IEC 68-2-27 (Shock Resistance)
  • EN 61000-4-4 / EN 61000-4-2 (Electromagnetic Compatibility Standards)

What is the maximum number of I/O terminals that can be connected to the BECKHOFF BK2000?

The BK2000 coupler supports the connection of up to 64 individual Beckhoff Bus Terminals.

What is the maximum current capacity of the K-bus output?

The BK2000 provides a maximum of 1.75 A to the K-bus to power the logic of connected terminals. If your system exceeds this limit, additional power feed terminals must be added.

Does the BK2000 support configuration via software?

Yes, the coupler features an integrated configuration interface that is compatible with Beckhoff's KS2000 software.

What are the environmental limits for operating the BK2000?

The BK2000 is rated for operation in temperatures ranging from 0 degC to +55 degC, with up to 95% non-condensing relative humidity.

Can the BK2000 be mounted in any direction?

Yes, the manufacturer specifies that the coupler can be mounted in any orientation on a standard DIN rail.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...