Description

Engineered for medium-scale automation applications, the CX5120-0143 embedded PC functions as a compact, DIN-rail-mountable controller utilizing an Intel Atom E3815 single-core processor running at 1.46 GHz. This industrial-grade embedded PC features hardware-assisted virtualization and integrated diagnostic indicators, facilitating real-time execution of complex PLC, motion control, and visualization tasks. It supports dual-bus compatibility, enabling automatic recognition and communication with both E-bus (EtherCAT) and K-bus (Bus Terminal) I/O systems.

The system comes equipped with 2 GB DDR3 RAM and an integrated 1-second UPS (Uninterruptible Power Supply) that stores up to 1 MB of persistent data on a CFast card. It offers diverse interface options, including two independent Gigabit Ethernet ports, a DVI-I video output, and four USB 2.0 ports, alongside a slot for optional hardware interfaces.

Features

  • Intel Atom E3815 processor (1.46 GHz, single core)
  • Dual-bus I/O connection with automatic recognition for E-bus and K-bus terminals
  • Integrated 1-second UPS (saves 1 MB of persistent data onto CFast card)
  • Robust Selection of physical interfaces: 2 x RJ45 ports (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0
  • Flexible operating system compatibility including TwinCAT/BSD, Windows Embedded Compact 7, Windows Embedded Standard 7 P, and Windows 10 IoT Enterprise
  • Diagnostics LEDs for Power, TwinCAT status, Flash access, and Bus status
  • Internal battery-backed real-time clock (exchangeable battery)

Applications

  • Industrial automation and process control systems
  • Machine tool automation and visualization (HMI)
  • Power generation and distribution monitoring
  • Water and wastewater treatment facilities
  • Building automation and smart infrastructure

Technical Specifications

Parameter Value
Manufacturer BECKHOFF
Part Number / Model CX5120-0143
Processor Intel Atom E3815, 1.46 GHz
Number of Cores 1
Main Memory 2 GB DDR3 RAM (not expandable)
Persistent Memory Integrated 1-second UPS (1 MB on CFast card)
Storage Slots Slot for CFast card and microSD card (cards not included)
I/O Connection E-bus (EtherCAT) or K-bus (Bus Terminal), automatic recognition
Current Supply E-bus/K-bus 2 A
Power Supply Voltage 24 V DC (-15% / +20%)
Max. Power Consumption 11 W (18 W when charging UPS)
TwinCAT 3 Platform Level Performance (40)
Dimensions (W x H x D) 122 mm x 100 mm x 92 mm
Weight Approx. 975 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Interface Type Function / Description
2 x RJ45 Ports 10/100/1000 Mbit/s Ethernet interfaces for networking and communication
1 x DVI-I Video connection for HMI panel or monitor
4 x USB 2.0 Type A interfaces for external peripherals, storage, or input devices
1 x Optional Slot Interface slot for optional factory-fitted extension modules

Installation Guidelines

  • Mounting: Install horizontally onto a standard 35 mm DIN rail (EN 60715). Ensure correct orientation with the cooling fins aligned vertically.
  • Clearance: Maintain a minimum ventilation clearance of 30 mm above and below the device to prevent thermal buildup.
  • Grounding: Ensure proper low-impedance connection of the DIN rail to the control cabinet's functional earth.
  • Wiring: Connect the 24 V DC supply voltage to the power terminal using appropriate wire gauges. Do not exceed the voltage limits of -15% / +20%.

Compliance and Certifications

  • CE, UL
  • Hazardous Locations (with CX2900-0107 ordering option):
    • ATEX: II 3 G Ex nA IIC T4 Gc, II 3 D Ex tc IIIC T135 degC Dc
    • IECEx: Ex nA IIC T4 Gc, Ex tc IIIC T135 degC Dc
    • cFMus: Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, AEx ec IIC T4 Gc

What type of I/O terminals are compatible with the CX5120-0143?

The CX5120-0143 supports both E-bus (EtherCAT Terminals) and K-bus (Bus Terminals) with automatic detection and configuration on the backplane.

Does the CX5120-0143 include memory cards?

No, the memory cards are not included. The device features slots for one CFast card and one microSD card, which must be ordered separately.

How does the integrated 1-second UPS function on this module?

The integrated 1-second UPS uses capacitive technology to provide backup power during a sudden power loss, allowing up to 1 MB of persistent data to be written safely onto the CFast card.

Can the 2 GB DDR3 RAM on this unit be expanded?

No, the 2 GB DDR3 RAM is integrated on-board and is not expandable.

What are the operational temperature limits for the CX5120-0143?

The operating temperature range is -25 to +60 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...