1 z 1

BECKHOFF IP2322-B318 Fieldbus Box Digital I/O Module

BECKHOFF IP2322-B318 Fieldbus Box Digital I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2322-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

For distributed automation layouts requiring robust environmental protection, the IP2322-B318 serves as a direct extension interface to the PROFIBUS DP network. This compact Fieldbus Box module integrates both input and output functionalities directly at the machine level, eliminating the need for protective control cabinets. By combining 4 digital inputs and 4 digital outputs into a single robust housing, it optimizes space and reduces wiring complexity in decentralized control architectures.

The IP2322-B318 features M12 connection interfaces for reliable sensor and actuator connection. It comes equipped with an integrated T-connector for PROFIBUS routing, enabling straightforward daisy-chain topology without additional external junctions. The digital inputs feature a standard 3 ms filter time, while the high-capacity digital outputs are capable of switching currents up to 2 A, making this module highly compatible with heavy solenoid valves and direct load applications.

Features

  • Direct integration into PROFIBUS DP networks.
  • Integrated T-connector for simplified fieldbus cabling.
  • 4 digital inputs (24 V DC) with a 3 ms filter delay.
  • 4 digital outputs (24 V DC) with up to 2 A load capacity per channel.
  • Highly durable IP67 housing design resistant to moisture and dust ingress.
  • Compact M12 connectors for stable signal transmission under high vibration.

Applications

  • Heavy industrial machinery and CNC equipment.
  • Automated conveyor systems and material handling.
  • Automotive assembly lines and robotic work cells.
  • Water treatment facilities and decentralized processing plants.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeProtocolNumber of InputsInput Filter TimeNumber of OutputsMax. Output CurrentFieldbus ConnectionI/O Connection MethodOperating TemperatureStorage TemperatureProtection ClassShipping Weight
BECKHOFF
IP2322-B318
Fieldbus Box I/O Module
PROFIBUS DP
4 digital inputs (24 V DC)
3 ms
4 digital outputs (24 V DC)
2 A per channel
M12 with integrated T-connector
M12 screw connectors
0 degC to +55 degC
-25 degC to +85 degC
IP67
2.0 kg

Installation Guidelines

Ensure that the mounting surface for the Fieldbus Box is flat to prevent structural stress on the housing. When routing cables, respect the minimum bending radius of the PROFIBUS and I/O lines. Tighten all M12 connectors to the recommended torque specifications to maintain the IP67 integrity. Proper functional grounding must be established via the integrated mounting holes to protect the system against electromagnetic interference.

What is the primary communication protocol of the Beckhoff IP2322-B318?

The IP2322-B318 module communicates via the PROFIBUS DP industrial network protocol.

What is the maximum output current supported per channel?

Each of the 4 digital output channels on this module can supply a maximum load current of up to 2 A.

Does this module require an additional protective enclosure?

No, the IP2322-B318 is rated at IP67, making it resistant to dust and moisture, allowing direct mounting on machines without a control cabinet.

How is the PROFIBUS connection configured?

The module utilizes an integrated M12 T-connector configuration, simplifying daisy-chain cabling of the PROFIBUS DP network.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...