1 z 1

Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP5009-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Decentralized acquisition of high-frequency sensor data is directly enabled by the Beckhoff IP5009-B318, an IP67-rated PROFIBUS DP Fieldbus Box designed for harsh operating environments. This module interfaces absolute encoders or displacement sensors utilizing the SSI (Synchronous Serial Interface) protocol, transferring data directly to the higher-level master controller via PROFIBUS DP. With integrated B-coded M12 connections acting as a built-in T-connector, the module allows for direct bus line looping without requiring external active junctions. Configuration and parameters can be easily adjusted using the KS2000 software tool or directly via controller-driven DP-V1 acyclic slot communication.

Features

  • PROFIBUS DP Compatibility: Complete support for baud rates up to 12 Mbaud with integrated automatic speed detection.
  • Rugged Enclosure Design: Full IP65, IP66, and IP67 protection ratings, eliminating the need for protective control cabinets in the field.
  • Integrated Loop-Through: M12 male and female B-coded interfaces enable simple daisy-chaining of the fieldbus line.
  • Flexible Configuration: Supports DP-V1 communication extensions for dynamic, runtime parameter adjustments.
  • Reliable Power Distribution: Standardized M8 connectors for control voltage and downstream load distribution.

Applications

  • Decentralized SSI absolute encoder feedback in packaging and material handling systems.
  • High-accuracy position sensing on outdoor linear axes and heavy machinery.
  • Automotive assembly lines requiring direct, field-mounted sensor integration.
  • Wind turbine pitch control systems and waste-water treatment plants.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number IP5009-B318
Fieldbus Protocol PROFIBUS DP (with DP-V1 support)
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Fieldbus Interface 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded
Control Voltage Supply 24 V DC (-15% / +20%)
Current Consumption (Box Supply) 85 mA + sensor load (max. 0.5 A)
Power Feed / Downstream 1 x M8 male socket (4-pin) / 1 x M8 female socket (4-pin)
Isolation (Control / Fieldbus) None (electrical isolation is determined by sensor configuration)
Cycle Time Approx. 0.5 ms (for typical network of 10 boxes with 32-bit I/O each)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Approvals CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Connection Pin Number Signal Assignment
PROFIBUS DP M12 (B-coded) Pin 1 VP (+5 V DC for active termination)
Pin 2 RxD/TxD-N (A-line, Green)
Pin 3 DGND (Data Ground)
Pin 4 RxD/TxD-P (B-line, Red)
Pin 5 Shield
Power M8 (Feed Connection) Pin 1 +24 V DC control voltage (Us)
Pin 2 +24 V DC load voltage (Up)
Pin 3 GND (Us)
Pin 4 GND (Up)

Alternative Models & Compatibility

The IP5009-B318 replaces several legacy non-coupled configurations by bringing SSI decoding down to the machine level. Ensure your GSD file is updated to include the exact module parameters to prevent cyclic data exchange errors with older master systems. For setups utilizing the EtherCAT network topology rather than PROFIBUS, the EP5001-0002 serves as the native EtherCAT fieldbus equivalent.

Application Pitfalls & Engineering Notes

When daisy-chaining multiple boxes via the M8 power distribution interfaces, calculate the total voltage drop. The cumulative control current (Us) should not exceed 4 A across a single segment to prevent high thermal stress on the internal bus rails. Since control voltage and fieldbus communications do not share electrical isolation inside the module, run all system fieldbus lines in separated, shielded trays to prevent EMI-induced communication dropouts.

Commissioning & Wiring Tips

For optimal performance, use a terminating resistor if the IP5009-B318 acts as the physical last node in the PROFIBUS segment. Standard active termination can be accomplished using an M12 B-coded terminator connected to the downstream socket interface. Ensure the SSI sensor cable is shielded and connected directly to the designated housing shield collar to maintain signal integrity during dynamic motor acceleration cycles.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate all electrical power sources before initiating installation, removal, or wiring processes. Verify that both control and load voltages (Us and Up) are fully de-energized. Failure to strictly follow these safety steps can cause immediate physical danger or catastrophic failures to connected high-precision SSI sensors.

1

Mount the Fieldbus Box on a flat, vibration-free surface using two M4 mounting screws.

2

Securely torque the M12 B-coded PROFIBUS cable connectors to prevent moisture and dust ingress.

3

Wire the M8 power supply connection, ensuring polarity matches for both control (Us) and load (Up) segments.

4

Verify connection status and baud rate sync via the diagnostic LEDs prior to running system processes.

What configuration tools are needed to set up the IP5009-B318?

Configuration can be achieved directly via the Beckhoff KS2000 software tool, or acyclically from your primary controller using DP-V1 PROFIBUS parameters.

Does this Fieldbus Box include integrated line termination?

No, it features a loop-through M12 B-coded connection. If placed at the end of the PROFIBUS line, an external M12 terminating resistor plug must be installed.

What is the maximum current limit for connected sensors?

The total sensor supply current is limited to a maximum of 0.5 A, in addition to the base box supply current of 85 mA.

Are the control voltage and fieldbus lines isolated from one another?

No. The IP5009-B318 does not feature electrical isolation between the control voltage input and the fieldbus communication circuit. Adequate field shielding is highly recommended.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...