1 z 1

Beckhoff KM1018-0001 Bus Terminal Digital Input Module

Beckhoff KM1018-0001 Bus Terminal Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KM1018-0001

  • Country of origin:Germany

  • Product Type: Bus Terminal Modules

  • Payment: T/T, Western Union

  • Weight: 310g

  • Dimensions: 123 mm x 100 mm x 55 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

High-density digital signal processing within the Beckhoff I/O system is efficiently managed by the KM1018-0001 Bus Terminal module. This compact 64-channel digital input module is engineered to capture binary control signals from the physical field level and transmit them with electrical isolation to the higher-level K-bus controller. With its high channel density and pluggable wiring configuration, this terminal module significantly reduces control cabinet footprint requirements while maintaining robust signal integrity.

The Beckhoff KM1018-0001 features a fast input filter time of typically 0.2 ms, making it highly suitable for applications demanding rapid state detection. Connection to the field inputs is established via a pluggable 1-wire connector level, enabling easy pre-assembly of the wiring harness and reducing downtime during maintenance. The module integrates seamlessly into standard DIN rail configurations, communicating directly with the process image through a 64-bit width mapping without requiring complex parameterization.

Features

  • 64 digital inputs structured in 8 groups of 8 channels.
  • Fast input filter of typically 0.2 ms for high-speed signal capture.
  • Pluggable 1-wire connection interface simplifies wiring and deployment.
  • Galvanic isolation of 500 V between the K-bus and the field potential.
  • Compact terminal block housing featuring double slot and key alignment for robust mounting.
  • No address settings or software configuration required for standard startup.

Applications

  • High-density electrical cabinet integration.
  • Packaging machinery and automated assembly lines.
  • Multi-axis machine tool automation.
  • Distributed sensor arrays in manufacturing plants.

Ordering Information

Model Number Configuration Connector Included
KM1018-0000 64-channel digital input, 24 V DC, 0.2 ms filter Without pluggable connector
KM1018-0001 64-channel digital input, 24 V DC, 0.2 ms filter 1-wire connector included
KM1018-0002 64-channel digital input, 24 V DC, 0.2 ms filter 1-wire connector with status LEDs
KM1018-0004 64-channel digital input, 24 V DC, 0.2 ms filter 3-wire connector with status LEDs

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Part Number / Model KM1018-0001
Number of Inputs 64 (8 x 8)
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (conforms to EN 61131-2, type 1)
"1" Signal Voltage 15 to 30 V (conforms to EN 61131-2, type 1)
Input Filter typ. 0.2 ms
Input Current typ. 5 mA
Current Consumption K-Bus typ. 3 mA
Electrical Isolation 500 V (K-bus / field potential)
Bit Width in Process Image 64 inputs
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Weight approx. 310 g (including 1-pin connector)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Terminal Interface Function Connection Properties
X1 to X8 Connectors 8 groups of 8 digital inputs Pluggable, 1-wire connection
Wire Cross-Section Solid/stranded conductors 0.08 to 1.5 mm²
Stripping Length Conductor preparation 8 mm

Installation Guidelines

  • Mounting: Attach to a standard 35 mm DIN rail conforming to EN 60715 using the integrated locking tab.
  • Alignment: Place side-by-side with adjacent K-bus terminals using the double slot and key connection points for optimal structural stability.
  • Wiring: Route signals using 1-wire plug connectors. Ensure wire terminations are stripped to exactly 8 mm before terminal insertion.
  • Shielding & Grounding: Ensure the mounting rail is clean, paint-free, and adequately grounded to provide low-impedance pathways for EMC transients.

Compliance and Certifications

  • CE

What is the key difference between the Beckhoff KM1018-0001 and KM1008 modules?

The primary difference lies in the input filter time. The KM1018 series features a typical input filter time of 0.2 ms, whereas the KM1008 series has a slower typical filter time of 3.0 ms.

Does the KM1018-0001 ship with pluggable connectors included?

Yes, the KM1018-0001 variant comes supplied with the pluggable 1-wire connector assembly needed for termination.

What is the process image bit width for this input module?

The KM1018-0001 occupies a bit width of 64 inputs in the system process image.

Is any software addressing required for installation?

No, the module is integrated into the I/O bus automatically and does not require manual address or hardware parameter configuration.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...