1 z 1

BECKHOFF KS4001 Analog Output Terminal

BECKHOFF KS4001 Analog Output Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS4001

  • Country of origin:Germany

  • Product Type: Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 85g

  • Dimensions: 6.8 cm x 1.2 cm x 10.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

The KS4001 is a precision 1-channel analog output terminal by BECKHOFF, designed to provide a high-resolution control signal of 0 to 10 V. Engineered for industrial automation, this terminal features a 12-bit resolution and a fast conversion time of approximately 1.5 ms. The KS4001 is equipped with a pluggable wiring level to streamline maintenance and installation. Its potential-free output and short-circuit-proof design ensure robust operation, making it ideal for interfacing with actuators or variable speed drives in a wide range of control applications.

Features

  • 1-channel analog output (0–10 V)
  • High precision with < ±0.1 % output error
  • 12-bit resolution for accurate control
  • Fast ~1.5 ms conversion time
  • Potential-free output for enhanced signal integrity
  • Short-circuit-proof design
  • Pluggable wiring system for quick field maintenance
  • Compact 12 mm wide housing for DIN rail mounting

Applications

  • Analog speed control for drives and motors
  • Precise position and pressure regulation
  • Valve and damper control
  • Signal generation for instrumentation and testing

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model KS4001
Number of Outputs 1
Signal Voltage 0 to 10 V
Resolution 12 bit
Output Error < ±0.1 %
Conversion Time ~ 1.5 ms
Electrical Isolation 500 V (K-bus/signal voltage)
Current Consumption (K-bus) typ. 75 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.085 kg
Protection Rating IP20

Installation Guidelines

  • Mount the terminal on a 35 mm DIN rail (EN 60715) and ensure the locking mechanism is engaged.
  • Utilize the double slot and key connection for stable, side-by-side assembly with other KS-series terminals.
  • Connect field wiring using the spring-actuated mechanism; maintain a stripping length of 9–10 mm.
  • Ensure cabling is compliant with the specified cross-section (0.08–1.5 mm2) for reliable connection.
  • Installation must be conducted in an environment within the -25 to +60 degC temperature range.
  • The terminal is designed for use in environments meeting EN 61000-6-2/EN 61000-6-4 EMC standards.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the resolution of the KS4001 analog output?

The terminal provides a 12-bit resolution for the 0–10 V output signal.

Is the output of this terminal isolated?

Yes, the output is potential-free and features 500 V electrical isolation between the K-bus and the signal voltage.

Does the KS4001 require any software configuration?

No, there are no address or configuration settings required; it is designed for simple, immediate integration.

What is the conversion time for this terminal?

The conversion time is approximately 1.5 ms.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...