1 z 3

Bently Nevada 190501-01-00-04 Velomitor CT Velocity Transducer

Bently Nevada 190501-01-00-04 Velomitor CT Velocity Transducer

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 190501-01-00-04

  • Country of origin:United States

  • Product Type: Velocity Transducers

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 960g

  • Dimensions: 30.5cm x 30cm x 4.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Designed specifically for the extreme conditions of wet cooling towers, the Bently Nevada 190501-01-00-04 is a specialized Velomitor CT Velocity Transducer engineered for low-speed machinery monitoring. This high-reliability vibration sensor measures casing vibration velocity, making it ideal for tracking structural and mechanical faults in cooling tower fans, gearboxes, and low-speed shaft assemblies.

The core construction of the 190501-01-00-04 features a hermetically sealed 316L stainless steel housing that completely isolates the internal sensing elements from 100% condensing humidity, corrosive water chemistry, and ambient contaminants. Unlike traditional velocity transducers that utilize moving coils prone to mechanical wear, this solid-state transducer employs internal integration electronics to convert acceleration measurements into a highly accurate velocity output signal, ensuring long-term measurement stability and minimal calibration drift.

Integrated easily into industrial monitoring systems, this sensor connects directly to the Bently Nevada 3500 Machinery Protection System via the 3500/42M Reciprocating Machinery Monitor or 3500/42 micro-locked channels, as well as distributed control systems (DCS) and PLC analog inputs that support dynamic vibration integration.

Features

  • Solid-state design with zero moving parts, eliminating mechanical wear and drift.
  • Hermetically sealed 316L stainless steel casing engineered to withstand continuous water exposure and wet cooling tower microclimates.
  • Internal integration circuit that converts acceleration to velocity for clean, noise-immune output signal transmission.
  • Optimized low-frequency response down to 1.5 Hz to capture structural resonance and low-speed rotational faults.
  • Standard top-exit 2-pin MIL-C-5015 connector configuration.
  • Broad dynamic range designed to capture both subtle imbalance forces and severe mechanical impacts.

Applications

  • Cooling tower fan drive assemblies
  • Air-cooled heat exchangers (fin fans)
  • Low-speed industrial gearboxes and agitators
  • Water and wastewater treatment circulating pumps
  • Exhaust ventilation systems

Technical Specifications

Manufacturer Bently Nevada
Part Number 190501-01-00-04
Series Velomitor CT (Cooling Tower) Velocity Transducer
Sensitivity 3.94 mV/mm/s (100 mV/in/s) plus/minus 5% at 100 Hz
Frequency Response 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) plus/minus 3.0 dB; 3.0 Hz to 900 Hz plus/minus 1.0 dB
Velocity Range 127 mm/s (5.0 in/s) peak
Transducer Orientation Omnidirectional (any angle of mounting)
Operating Temperature -40 degC to +121 degC (-40 degF to +250 degF)
Excitation Voltage 15 to 30 VDC (2 to 10 mA constant current source)
Output Impedance Less than 100 Ohms
Case Material 316L stainless steel
Enclosure Rating Hermetically sealed, equivalent to IP66/IP68
Connector Type 2-pin MIL-C-5015 top connector
Mounting Thread 1/2-20 UNF (Option -01 configuration)

Connections and Interfaces

MIL-C-5015 Pin Signal Designation
Pin A Signal / Power (+)
Pin B Common / Return (-)
Shield Connected to transducer case internally (or isolated based on system grounding protocol)

Installation Guidelines

  • Mounting Torque: Tighten the transducer to the mounting surface using a maximum torque of 34 N-m (25 ft-lb) to ensure proper acoustic coupling without damaging the sensor threads.
  • Surface Preparation: Ensure the mating surface is flat, clean, and free of paint, scale, or debris. Use a light coating of silicone grease or coupling fluid before mounting.
  • Cabling and Routing: Always use shielded, twisted-pair cabling to minimize electromagnetic interference (EMI). Route cables through protective conduit or secure them with heavy-duty cable ties in cooling tower plenums to prevent mechanical strain.
  • Grounding: Ensure the shield is grounded at the monitor end only to prevent ground loops that introduce electronic noise into the vibration signal.

Compliance and Certifications

  • ATEX (Zone 0/1/2 Hazardous Areas)
  • IECEx
  • CSA/US Class I, Division 1 & 2 Groups A, B, C, D
  • CE Compliant

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 190501-01-00-04 Velomitor CT Velocity Transducer

What is the primary difference between the standard Velomitor and the Velomitor CT?

The Velomitor CT (Cooling Tower) is specially optimized for low-frequency vibration monitoring (down to 1.5 Hz) and features a more robust hermetic seal to withstand the 100% condensing humidity and corrosive environment found inside cooling towers.

Does the 190501-01-00-04 Velomitor CT require an external transmitter?

No, it is a self-contained transducer that outputs a low-impedance voltage signal proportional to velocity. It can be wired directly to vibration monitors (like Bently Nevada 3500) or PLC/DCS analog input cards that accept 2-wire constant-current accelerometers/velocity sensors.

What mounting configuration is specified by the -01 option in the 190501-01-00-04 part number?

The -01 mounting option specifies a 1/2-20 UNF threaded mounting adapter for secure mechanical coupling to the machinery casing.

What is the recommended operating temperature range for this velocity sensor?

The sensor operates reliably across a temperature range of -40 degC to +121 degC (-40 degF to +250 degF).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...