1 z 1

Danfoss KPS79 060L310466 KPS Series Thermostat

Danfoss KPS79 060L310466 KPS Series Thermostat

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L310466

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The Danfoss KPS79 060L310466 is a KPS series thermostat engineered for robust temperature control in demanding industrial applications. This KPS 79 unit utilizes a capillary tube sensing system to provide accurate switching within a defined setting range. Designed for high reliability, the device is suitable for monitoring and controlling temperature in fluid or gas systems where precise, adjustable differential control is required. The 060L310466 provides stable performance in harsh environments, ensuring effective thermal management for automated industrial processes.

Features

  • Adjustable temperature setting range of 50 to 100 Celsius.
  • Integrated adjustable mechanical differential (4 to 16 Celsius).
  • Durable capillary tube design with 2 m length.
  • High maximum sensor temperature tolerance up to 200 Celsius.
  • Suitable for use with various sensor pocket lengths for flexible installation.

Applications

  • Heating, ventilation, and air conditioning (HVAC) systems.
  • Industrial process temperature regulation.
  • Cooling water circuits.
  • Boilers and heat exchangers.
  • Compressor and pump protection.

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model KPS79 060L310466
Series KPS
Setting Range 50 – 100 Celsius
Mechanical Differential 4 – 16 Celsius (Adjustable)
Max Sensor Temperature 200 Celsius
Capillary Tube Length 2 m
Compatible Sensor Pockets 65 mm, 75 mm, 110 mm, 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the thermostat enclosure is mounted in a stable location free from excessive vibration.
  • Sensor Placement: The sensor bulb must be fully immersed in the medium being monitored to ensure accurate temperature sensing. Use appropriate thermowells or pockets as specified.
  • Capillary Handling: Avoid sharp bends or kinks in the 2 m capillary tube, as this can damage the internal system and affect accuracy.
  • Calibration: After installation, verify the switching point within the 50 – 100 Celsius range and adjust the differential as required for the specific process load.
  • Environment: Protect the housing from direct exposure to corrosive substances or moisture ingress.

What is the adjustable temperature range for the KPS79?

The setting range for this unit is between 50 Celsius and 100 Celsius.

Can the mechanical differential be adjusted on this model?

Yes, the mechanical differential is adjustable between 4 Celsius and 16 Celsius to suit specific process requirements.

What is the maximum temperature the sensor can withstand?

The maximum sensor temperature for this device is 200 Celsius.

What is the length of the capillary tube included with this unit?

This unit is equipped with a 2 meter long capillary tube.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...