1 z 6

E82ZZ75134B210 Lenze 8200-Series RFI Filter 3.4 A / 500 V

E82ZZ75134B210 Lenze 8200-Series RFI Filter 3.4 A / 500 V

Only 10 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82ZZ75134B210

  • Country of origin:Germany

  • Product Type: Accessories

  • Barcode: 85044086

  • Payment: T/T, Western Union

  • Weight: 620g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Product Overview

The E82ZZ75134B210 (E82ZZ75134B210) is a high-performance Radio Frequency Interference (RFI) filter specifically engineered for the Lenze 8200-series frequency inverters. Rated for a three-phase 500 V supply at 3.4 A, this specialized accessory is designed to suppress electromagnetic disturbances conducted via the mains supply line. By attenuating high-frequency noise generated by the inverter's power stage switching, the E82ZZ75134B210 ensures that the entire drive system complies with stringent international EMC (Electromagnetic Compatibility) standards. This filter is essential for protecting sensitive downstream electronics, such as PLCs, sensors, and communication equipment, from disruptive electrical noise. Despite its "Obsolete" status, it remains a critical component for stabilizing legacy 8200-series installations in high-precision manufacturing and processing environments.

Technical Configuration

The E82ZZ75134B210 features a robust LC-circuit architecture optimized for the switching frequencies common in 8200-series AC drives. It is designed for "footprint" or side-by-side mounting, allowing for an integrated, space-efficient assembly within the control cabinet. The hardware utilizes high-grade capacitors and inductive chokes to provide maximum attenuation of common-mode and differential-mode interference across a broad frequency spectrum (150 kHz to 30 MHz). Its 50/60 Hz compatibility and 500 V rating allow for global application in various industrial grid configurations. The filter is enclosed in a durable metal housing that acts as a Faraday cage, further minimizing radiated emissions and providing a reliable ground path for parasitic currents.

Technical Specifications

Feature Specification
Model E82ZZ75134B210
Brand Lenze
Series 8200-Series Accessories
Product Type RFI Filter / Mains Filter
Rated Current 3.4 A
Rated Voltage 3 x 500 VAC
Frequency 50 / 60 Hz
Weight 0.62 kg
Phases 3-Phase
Product Phase Obsolete
Application EMC Suppression for 8200-series Drives

Technical FAQs

Does the E82ZZ75134B210 protect the inverter from lightning strikes?

No. This is an RFI filter designed for high-frequency noise suppression. For protection against high-energy surges or lightning, a dedicated surge protection device (SPD) or lightning arrester must be installed at the main power entry point.

Can I use a 3.4 A filter for a drive with a higher current rating?

No. The filter must be sized according to the continuous input current of the drive. Using a 3.4 A filter for a higher-power drive will cause the internal inductors to saturate and overheat, potentially leading to a fire hazard or permanent filter failure.

Is there a specific mounting orientation required for this filter?

While the filter can technically function in any orientation, it is recommended to mount it directly underneath (footprint) or immediately adjacent to the inverter. This keeps the unshielded cable length between the filter and the inverter as short as possible to prevent noise re-entry.


Engineering & Installation Guide

  • Minimizing Cable Length: The lead length between the E82ZZ75134B210 and the frequency inverter should not exceed 30 cm. Longer leads act as antennas and can re-radiate the interference that the filter is designed to suppress. Use twisted-pair wiring for the connection to further cancel out magnetic fields.

  • Surface Grounding: To achieve effective suppression, the metal housing of the E82ZZ75134B210 must have a large-surface-area connection to the grounded mounting plate. Ensure the mounting plate is zinc-plated or that any paint is removed at the contact points to provide a low-impedance path for high-frequency currents.

  • Leakage Current Awareness: RFI filters contain capacitors connected to ground, which results in operational leakage currents. When using the E82ZZ75134B210, ensure that any upstream Residual Current Devices (RCDs) are "Type B" or "Type B+" and have a trip threshold appropriate for the cumulative leakage of the drive system to prevent nuisance tripping.

 

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...