1 z 3

GE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D Breaker Protection System

GE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D Breaker Protection System

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D

  • Country of origin:United States

  • Product Type: Protection Relays

  • Payment: T/T, Western Union

  • Weight: 8500g

  • Dimensions: 483 mm x 177 mm x 274 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The GE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D is a substation-hardened protection, control, and monitoring unit designed for circuit breaker management in substation and industrial automation applications. It supports complex dual-breaker busbar configurations—such as breaker-and-a-half or ring bus schemes—and provides integrated protection functions, including breaker failure detection, multi-shot autoreclosing, synchrocheck, overcurrent, overvoltage, and sensitive directional power elements.

Equipped with high-density I/O configurations, advanced time synchronization, and robust communication protocol support (such as IEC 61850, DNP 3.0, Modbus TCP/IP, and IEC 60870-5-104), the GE Multilin C60K03HKHF8LH67M67P6CU6DW6D enables deterministic control logic execution and real-time visualization via an integrated color HMI panel.

Features

  • Integrated Breaker Management: Complete protection, control, and monitoring in a unified modular platform.
  • Dual-Breaker Support: Native functionality for breaker-and-a-half and ring bus arrangements with internal summation of up to 4 CT sets.
  • FlexLogic Engine: High-speed programmable logic engine supporting up to 1024 lines of custom control schemes.
  • Advanced Protection Elements: Includes breaker failure, 10-element synchrocheck, multi-shot autoreclosure, overvoltage, directional power, and thermal overload features.
  • High-Density I/O Flexibility: Scalable hardware architecture with selectable digital I/O options to support wide switchyard automation needs.
  • Comprehensive Disturbance Recording: Advanced event recorder (1024 events), COMTRADE oscillography (up to 64 digital / 40 analog channels), fault summary reporting, and data logging capabilities.
  • Substation Communication: Features advanced Ethernet options with support for IEC 61850 Ed. 1/Ed. 2, PRP (IEC 62439-3), Routable GOOSE, IEEE 1588 time synchronization, and CyberSentry security.
  • Human-Machine Interface: Graphical front panel display with user-programmable pushbuttons, status LEDs, and bay display options.

Applications

  • Stand-alone breaker monitoring and control
  • Breaker-and-a-half and ring bus scheme management
  • Automatic bus transfer (main-tie-main) schemes using a single device
  • Distributed bay control in utility and industrial substations
  • Synchronism check and reclosing applications

Ordering Information

Model Code Segment Option Code Description
Base Unit C60 Full Sized Horizontal Mount / Standard C60 Breaker Protection System
CPU K RS485 + two 100BaseFX Eth, Multimode ST + one 10/100BaseT Eth, RJ-45
Software Options 03 Ethernet Global Data
Mount H Horizontal (19" rack) - Standard
User Interface K Enhanced English Front Panel with User-Programmable Pushbuttons
Power Supply H 125/250 V AC/DC
CT/VT DSP F8L Standard 4CT/4VT w/ enhanced diagnostics
IEC 61850 Process Bus H67 No module
Digital I/O (Slot M) M67 8 Form-A (No Monitoring) Outputs
Digital I/O (Slot P) P6C 8 Form-C Outputs
Digital I/O (Slot U) U6D 16 Digital Inputs
Digital I/O (Slot W) W6D 16 Digital Inputs

Technical Specifications

Category Specification Parameter / Value
General Manufacturer GE Grid Solutions (General Electric)
  Series Multilin UR (Universal Relay) Family
  Device Type Breaker Protection System / Controller
Power Supply Voltage Rating 125/250 V AC/DC
CT/VT Inputs Standard Input Config 4 CT / 4 VT with Enhanced Diagnostics
Digital Input/Output Slot M Output Configuration 8 Form-A (No Monitoring) Outputs
  Slot P Output Configuration 8 Form-C Outputs
  Slot U Input Configuration 16 Digital Inputs
  Slot W Input Configuration 16 Digital Inputs
Communication Interfaces Serial RS485 Port
  Fiber Ethernet 2x 100BaseFX (Multimode ST connectors)
  Copper Ethernet 1x 10/100BaseT (RJ-45 connector)
  Software Protocols Ethernet Global Data (EGD), Modbus, DNP 3.0, IEC protocols
Form Factor & Mounting Mounting Style Horizontal (19-inch rack)
Front Panel HMI Display & Controls Enhanced English Front Panel with User-Programmable Pushbuttons & LEDs
Data & Event Recording Sequence of Events (SOE) Up to 1024 time-stamped events
  Oscillography IEEE C37.111-1999/2013, IEC 60255-24 Ed 2.0 COMTRADE format

Installation Guidelines

  • Rack Mounting: Install horizontally into a standard 19-inch rack enclosure. Ensure proper ventilation and clearance around the chassis to allow heat dissipation.
  • Grounding: Connect the protective grounding lug directly to the main substation ground bus using low-impedance ground straps to minimize EMI/RFI noise interference.
  • Power Supply Wiring: Verify the control power supply matches the 125/250 V AC/DC nominal operating voltage before energizing the module. Ensure proper fusing on incoming power lines.
  • CT/VT Connections: Ensure correct polarity and phase orientation when wiring current transformer and voltage transformer inputs. Never open-circuit energized CT secondary circuits.
  • Fiber-Optic Cables: Maintain recommended bend radii for ST fiber-optic Ethernet connections to prevent signal attenuation or physical fiber damage.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin C60-K03-HKH-F8L-H67-M67-P6C-U6D-W6D Breaker Protection System

What primary functions are provided by this breaker management unit?

The device provides complete protection, control, metering, and monitoring for circuit breakers, supporting single and dual-breaker arrangements like breaker-and-a-half or ring bus configurations.

Which communication interfaces are available on the CPU module?

The CPU module includes one RS485 port, two 100BaseFX multimode fiber Ethernet ports with ST connectors, and one 10/100BaseT copper Ethernet port with an RJ-45 connector.

What type of power supply does the unit support?

The device operates on a standard 125/250 V AC/DC control power supply.

How many digital inputs and outputs are available in this configuration?

This specific unit provides 32 digital inputs (across two input slots) and 16 output contacts (8 Form-A outputs and 8 Form-C outputs).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizace HMI systémů Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce nahrazením zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci systému Alpha, migraci na OpenVMS x86, přechod na platformu OPC a postupnou...

Proč jsou údaje o údržbě zásadní pro spolehlivost průmyslových zařízení

Údržbová data propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Při správném využití zlepšují plánování, spolehlivost, prediktivní údržbu, řízení...

Elektrické pohony navržené jako náhrada fluidních energetických systémů: praktický průvodce průmyslovou automatizací

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator společnosti SMC, mění průmyslové řízení pohybu tím, že nahrazují tradiční pneumatické a hydraulické systémy....

Matematické operace pomocí OpenPLC pro aplikace průmyslové automatizace

Tento článek vysvětluje, jak systémy PLC provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování, v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá booleovská logika s programováním PLC pomocí FBD: praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí booleovské logiky používaných při programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se nástroje jako pravdivostní tabulky,...

Booleovská logika v programování PLC: porozumění logickým hradlům FBD

Booleovská logika je základem každého programu PLC. Od jednoduchého řízení strojů až po komplexní systémy průmyslové automatizace logická hradla určují, jak řídicí jednotky reagují na měnící se...