1 z 3

General Electric Mark VIe IS230TRLSH2B Relay Output Module

General Electric Mark VIe IS230TRLSH2B Relay Output Module

Only 7 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS230TRLSH2B

  • Country of origin:United States

  • Product Type: Relay Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2920g

  • Dimensions: 34cm x 22.5cm x 11.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The General Electric IS230TRLSH2B is a specialized relay output terminal board module designed for the Mark VIe control system platform. This Relay Output Module interfaces with control processors to safely drive field solenoids, control valves, motor starters, and external interlock circuits across heavy industrial environments. Operating as a component within the distributed control architecture, it receives digital commands from the system controller and converts them into physical, isolated dry contact closures or voltage switching states. It is engineered specifically for system compatibility within large-scale utility and turbine control frameworks, providing robust physical separation between low-voltage microelectronic control loops and high-voltage field execution circuitry.

Features

  • Built for reliable physical and electrical galvanic isolation within the modular framework
  • Designed to accept high-speed logic state signals from upstream control layers
  • Equipped with rugged on-board relays configured for continuous operational duty
  • Features terminal block junctions directly on the board assembly for secure field loop routing
  • Integrates seamlessly with multi-channel architecture to minimize cabinet hardware footprints

Applications

  • Distributed Control Systems (DCS) for gas, steam, and hydro turbine regulation
  • Solenoid valve control and auxiliary pump startup staging
  • Safety interlock processing and remote equipment trip circuits
  • Heavy industrial power plant, manufacturing, and critical system infrastructure automation

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model Designation IS230TRLSH2B
System Series Mark VIe Control System
Module Type Relay Output Terminal Board Module
Country of Origin USA
Channel Configuration Multi-channel dedicated relay outputs
Enclosure / Mounting Panel or base assembly carrier layout
Operating Temperature 0 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Humidity Constraints 5% to 95% non-condensing relative humidity

Connections/Interfaces

Terminal Assignment Function
Screw Terminals (Field Side) Field device loop connections (Form-C or Form-A contacts)
I/O Pack Connector High-density multi-pin communication bridge to the primary controller
Shield Terminals Shield drain wire termination ground points for EMI containment

Installation Guidelines

Cabinet Orientation & Mounting

Secure the module onto its designated backplate or carrier structure inside the control cabinet. Ensure the mounting fasteners are fully tightened to ground the underlying metal chassis panel and isolate the board from excessive high-frequency structural vibration.

Cable Shielding & Routing

Route all digital signal cables separate from heavy AC power lines to protect against inductive cross-coupling and electrical noise. Terminate field wire shields only at the specified system ground point on the board frame.

Connection Torques

When tightening the terminal block screws for field loops, torque them according to standard industrial terminal specifications to prevent loose contact junctions or intermittent continuity dropouts during thermal cycling.

What primary function does this board perform in the system?

The module operates as a relay output interface, receiving electronic logic commands from the controller and activating physical relay contacts to switch external field loads safely.

How should shield drain wires be terminated on this board?

Shield drain wires must be connected directly to the dedicated shield termination points provided on the module frame to secure effective path-to-ground noise mitigation.

What is the recommended storage temperature range for this module?

The safe storage temperature limit for this module spans from -40 degC to +85 degC under non-condensing atmospheric conditions.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...