1 z 1

Honeywell TC-FPCXX2 Experion Series Power Supply Module

Honeywell TC-FPCXX2 Experion Series Power Supply Module

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TC-FPCXX2

  • Country of origin:United States

  • Product Type: PLC Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 2100g

  • Dimensions: 11.2 cm x 14.5 cm x 14.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Providing regulated operating power to local rack configurations, the Honeywell TC-FPCXX2 serves as a high-reliability chassis power supply module engineered for industrial process control environments. This module accepts selectable AC input ranges to deliver a maximum continuous output of 70 W at 60 degC, ensuring stable voltage distribution to adjacent controller and I/O modules. The unit incorporates integrated thermal protection and structural overcurrent safeguarding via an onboard soldered internal fuse to maintain system integrity under transient fault conditions.

Key Features

  • Dual-Range Input: Field-selectable slide switch accommodates both 85-132 VAC and 170-265 VAC nominal input voltages.
  • Thermal De-rating Performance: Capable of delivering a full 70 W power envelope at ambient temperatures up to 60 degC.
  • Robust Fault Isolation: Features a factory-soldered, non-replaceable internal input fuse to protect upstream distribution systems.
  • Form Factor Integration: Standard chassis slot footprint allows direct insertion into compatible Honeywell controller backplanes.

Applications

  • Honeywell Experion LX control systems and regional I/O rack power distribution.
  • Legacy PlantScape controller chassis retrofits and upgrades.
  • Distributed Control System (DCS) nodes in petrochemical, refining, and water treatment utilities.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Model Reference TC-FPCXX2
Input Voltage Range 85-132 VAC or 170-265 VAC (User-selectable via slide switch)
Line Frequency Range 47-63 Hz
Maximum Output Power 70 W at 60 degC
Overcurrent Protection Non-replaceable soldered-in input fuse
Module Dimensions (W x D x H) 11.2 cm x 14.5 cm x 14.0 cm (4.41 in x 5.71 in x 5.51 in)
Net Module Weight 1.1 kg (2.43 lbs)
Shipping Weight (Calculated) 2.1 kg (4.63 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The TC-FPCXX2 is functionally interchangeable with older Honeywell legacy chassis power options, but caution must be exercised regarding mounting pitch and backplane connector alignment. While standard C200 controllers utilize similar configurations, always verify that the chassis slot keying matches the deep-recessed connector housing on the back of this module before attempting hot insertion.

Application Pitfalls & Engineering Notes

Because this power supply uses a non-replaceable, soldered-in input fuse, external overcurrent protection (such as an inline terminal block fuse or miniature circuit breaker rated at 5 A or 10 A depending on input configuration) is highly recommended. If an internal component fault triggers the soldered fuse, the entire unit must be serviced or replaced; external fusing mitigates transient line surges from rendering the module permanently inoperable on site.

Commissioning & Wiring Tips

Before applying power, verify the position of the dual-voltage slide selector switch located on the unit. Energizing a module configured for 115 VAC with a 230 VAC supply line will cause immediate, catastrophic damage to the input varistors and internal circuitry, voiding standard field warranties.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all incoming AC power lines before mounting or sliding the power module into the chassis. Do not touch terminal screws or the rear connector interface while the main bus is energized. Failure to comply can result in severe electrical shock, equipment destruction, or unexpected process downtime.

1

Locate the input voltage selector switch on the side or rear of the module. Confirm its setting matches your local utility supply level (115 VAC or 230 VAC nominal).

2

Align the module with the guide rails of the designated left-most power supply slot in the chassis.

3

Slide the module firmly backward until the rear interface connector seats fully into the backplane socket. Hand-tighten the integrated retaining screws to secure the unit structurally.

4

Connect the external, de-energized AC supply wiring to the input terminals, ensuring the protective earth ground wire is established first.

Can I replace the internal fuse of the Honeywell TC-FPCXX2 in the field?

No. The TC-FPCXX2 features a factory-soldered internal fuse that is not field-replaceable. If the fuse blows, the module must be serviced by qualified personnel or replaced entirely. It is highly recommended to install external fast-acting fuses on the AC incoming lines to prevent catastrophic internal failures.

How do I switch the TC-FPCXX2 between 115 VAC and 230 VAC inputs?

The module utilizes a physical slide switch located on its casing to select between the 85-132 VAC and 170-265 VAC ranges. Ensure this switch is correctly positioned before mounting the module or applying primary power to avoid immediate hardware damage.

What is the maximum output wattage under high thermal conditions?

The TC-FPCXX2 delivers a maximum total power output of 70 Watts at operating temperatures up to 60 degrees Celsius.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...