Product Overview

Providing precise speed and torque control for three-phase asynchronous motors, the Lenze E84AVSCE7514SX0 is an industrial frequency inverter designed for space-saving control cabinet installation. Operating on a 3-phase 400/500 V AC mains supply, this 0.75 kW (1.0 HP) rated unit belongs to the highly reliable 8400 StateLine series. It features integrated interference suppression measures to ensure electromagnetic compatibility (EMC) in demanding industrial environments, minimizing electrical noise without requiring external filter modules in standard configurations.

Key Features

  • Optimized for cabinet installation with a compact IP20 housing design.
  • Integrated EMC filter (interference suppression) compliant with industrial standards.
  • V/f characteristic control (linear or quadratic) and sensorless vector control for dynamic torque response.
  • Monitored ramp functions, quick stop, and DC braking for controlled deceleration.
  • Onboard CANopen system bus interface for seamless integration into distributed automation architectures.

Applications

  • Conveyor systems and material handling lines
  • Industrial pumps, fans, and ventilation blowers
  • Packaging machinery and indexing tables
  • Machine tool auxiliary drives

Technical Specifications

Parameter Value
Manufacturer Lenze
Model Code E84AVSCE7514SX0
Series 8400 StateLine
Mains Voltage 3 AC 400 V / 500 V (50/60 Hz)
Rated Power 0.75 kW (1.0 HP)
Enclosure Rating IP20
Communication Interface CANopen (onboard)
Country of Origin Germany
Product Weight 1.20 kg
Dimensions (H x W x D) 180 x 140 x 80 mm
Commodity Code 85044095

Empirical Engineering Insights

Alternative Models & Compatibility

The E84AVSCE7514SX0 belongs to the 8400 StateLine family. It can directly replace older 8200 vector series drives of equivalent power ratings, though physical mounting footprints and control terminal layouts differ. Ensure that any existing CANopen configuration files (.EDS) are updated in your PLC master (such as a Siemens S7 or Lenze Controller) to reflect the 8400 StateLine profile.

Application Pitfalls & Engineering Notes

When operating at the upper limit of 500 V AC, thermal dissipation increases slightly. Maintain a minimum clearance of 100 mm above and below the unit inside the enclosure to prevent localized overheating. Avoid running the drive continuously below 10 Hz without an external forced-cooling fan on the motor, as standard self-ventilated motors will overheat at low speeds under constant torque loads.

Commissioning & Wiring Tips

Use shielded motor cables with a low-impedance 360-degree shield connection at both the drive's PE bracket and the motor terminal box. Commissioning is best performed using the Lenze L-force Engineer software via an optional USB diagnostic adapter (E84DGCDXM). Ensure the termination resistor (120 Ohm) is switched on at the physical ends of the CANopen network segment.

Installation Guidelines

CRITICAL WARNING: Hazardous electrical voltage remains present in the internal DC-bus capacitors for up to 5 minutes after disconnecting the mains supply. Always verify that the DC-bus voltage has discharged to 0 V using a calibrated digital multimeter before handling any power terminals or wiring connections. Failure to comply can result in severe electrical shock or death.
1
Mount the drive vertically on a flat, vibration-free backplate inside an IP54 or higher rated control cabinet to protect against dust and moisture.
2
Connect the protective earth (PE) conductor to the designated grounding terminal prior to making any other electrical connections.
3
Wire the 3-phase AC mains supply to terminals L1, L2, and L3, and the motor phases to terminals U, V, and W using shielded cable.
4
Connect the control terminals and the CANopen bus lines, ensuring proper shielding and routing away from high-voltage power cables.

What is the primary communication interface on the E84AVSCE7514SX0?

This drive features an integrated CANopen system bus interface directly on board, allowing seamless integration into CAN-based industrial networks.

Can this drive be used with single-phase input power?

No, this model is strictly designed for a 3-phase mains connection of 400 V to 500 V AC at 50/60 Hz.

What software is required to configure and commission this inverter?

The drive is commissioned using the Lenze L-force Engineer software suite, which connects via an optional USB diagnostic adapter.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...