1 z 1

Mitsubishi Electric FR-A740-22K-CHT A700 Series Variable Frequency Drive

Mitsubishi Electric FR-A740-22K-CHT A700 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A740-22K-CHT

  • Country of origin:United States

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 430 x 290 x 260 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Designed for exceptional motor control in high-demand environments, the Mitsubishi Electric FR-A740-22K-CHT provides precise variable frequency speed and torque management for three-phase induction motors. As a part of the high-performance A700 Series, this 22 kW drive features advanced vector control algorithms and robust electrical protections. It is built to ensure seamless operation under continuous heavy-duty loads while maintaining excellent thermal efficiency.

Key Technical Features

  • Advanced Vector Control: Supports offline/online auto-tuning for premium flux vector performance without speed sensors.
  • High Overload Threshold: Tolerates transient current surges up to 150% for 60 seconds and 200% for 3 seconds to protect against mechanical blockages.
  • Continuous Thermal Capacity: Engineered with forced-air fan cooling to support full-load operations up to an ambient temperature of 50 degC.
  • IP20 Enclosed Protection: Compact housing designed for integration into standard industrial cabinets and control rooms.

Industrial Applications

  • Heavy manufacturing machinery including extruders, mixers, and rotary kilns.
  • High-inertia material handling systems, industrial conveyors, and automated cranes.
  • Large centrifugal fans, exhaust blowers, and municipal booster pumps.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number FR-A740-22K-CHT
Series Type A700 Series
Applicable Motor Capacity 22 kW
Rated Output Current 44 A
Rated Capacity 32.8 kVA
Rated Voltage (Output) Three-phase 380V to 480V
Rated Input AC Voltage / Frequency Three-phase 380V to 480V, 50Hz/60Hz
Permissible AC Voltage Fluctuation 323V to 528V, 50Hz/60Hz
Permissible Frequency Fluctuation +/- 5%
Power Supply Capacity 41 kVA
Protective Rating IP20 Enclosed Type
Cooling Method Forced Air Cooling
Country of Origin Japan
Shipping Weight (Calculated) 14.0 kg
Package Dimensions (Calculated) 430 x 290 x 260 mm

Power and Control Terminals

Terminal Symbol Terminal Name Functional Assignment
R/L1, S/L2, T/L3 AC Power Input Connection to commercial three-phase mains supply.
U, V, W Inverter Output Connection to the external three-phase induction motor.
P/+, PR Braking Resistor Connection point for dynamic braking options.
STF / STR Forward / Reverse Start External signal command triggers for directional rotation.
SD Signal Common (Sink) Common ground terminal for digital inputs configured to sink logic.

Empirical Engineering Insights

Alternative Models & Compatibility

The "CHT" suffix designates a localized firmware and default parameter configuration optimized for standard Asian markets, meaning the default base frequency is 50Hz and digital control terminals default to sink (negative) logic. This drive is a direct drop-in replacement for standard FR-A740-22K units, provided parameters like Pr. 3 (Base Frequency) and the internal logic jumper are verified and calibrated to your local wiring standards.

Application Pitfalls & Engineering Notes

For dynamic systems with highly cyclical braking or large physical inertia, the drive's built-in 20% torque permissible duty might trigger regenerative overvoltage faults (E.OV3). Integrating a dedicated external dynamic braking unit (such as the FR-BU2 series) alongside dynamic resistors is highly recommended to protect the internal DC bus. When mounting inside completely closed IP54 panels, ensure cabinet dimensions allow the dissipation of approximately 650 Watts of thermal energy produced by the drive at full load.

Commissioning & Wiring Tips

Always isolate the control signaling cable from high-voltage motor output lines by keeping a separation distance of at least 10 cm, or utilize dedicated metal conduit separation. For analog control signals (terminals 2, 4, 1), use shielded twisted-pair cabling and tie the shield to control ground (terminal 5) at the drive end only. This mitigates high-frequency noise from corrupting speed references.

Installation Guidelines

CRITICAL SAFETY WARNING:

Ensure all primary AC feed lines are de-energized prior to beginning installation. The internal DC bus capacitors contain dangerous residual charge. Wait a minimum of 10 minutes after disconnecting power, and confirm the physical "CHARGE" LED on the control board is fully extinguished before performing any terminal modifications or wire connections.

1

Vertical Orientation: Always mount the drive vertically inside the panel to leverage built-in forced-air convection dynamics.

2

Clearance Tolerances: Maintain at least 100 mm of open vertical space above and below the device, and a minimum of 50 mm horizontal distance from side components.

3

Protective Earthing: Connect the dedicated ground terminal (PE) to an active system ground. Keep grounding resistance below 10 ohms to prevent electrostatic interference.

What does the CHT suffix represent on this variable frequency drive?

The CHT suffix designates that the drive is configured with factory defaults optimized for the Asian regional market, meaning base frequency defaults to 50Hz and control terminal circuitry is set for sink logic. Hardware-wise, it remains fully compatible with other A740 series variants.

Can this unit run on a single-phase electrical supply?

No. This drive requires a robust three-phase AC input supply voltage between 380V and 480V. Running on single-phase inputs will cause phase loss faults and can result in severe internal hardware damage.

How do I resolve an E.OV3 fault during deceleration cycles?

An E.OV3 fault indicates DC bus overvoltage. To prevent this, increase the deceleration time parameter or connect an external dynamic braking resistor across terminals P/+ and PR.

What is the recommended ambient air temperature range for this drive?

The drive is designed to operate continuously in ambient conditions from -10 degC to +50 degC, assuming non-freezing and clean industrial panel environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...