1 z 1

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CJ1W AD081-V1

  • Country of origin:Japan

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 150g

  • Dimensions: 31 mm x 90 mm x 89 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

For high-density process data acquisition in industrial environments, the CJ1W-AD081-V1 serves as a reliable multi-channel analog input unit within the Sysmac CJ-series PLC platform. This module supports up to eight analog input channels on a single slot, making it highly efficient for cabinets with limited footprint. It interfaces directly with CJ1, CJ2, and compatible CPU racks via the system bus, facilitating rapid data transfers and streamlined diagnostic monitoring.

Each channel can be independently configured for different input signal types, allowing engineers to mix voltage and current signals on the same physical module. Key processing functions integrated directly into the hardware include scaling, peak hold, mean value processing, and input wire-disconnection detection, which reduces the computational load on the main CPU.

Features

  • Supports up to 8 analog input channels in a compact single-slot width.
  • Independently configurable inputs for voltage (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V) and current (4 to 20 mA).
  • High-speed conversion rate of 250 microseconds per point (2 milliseconds total for all 8 points).
  • High-resolution conversion mode up to 1/8000 (standard mode is 1/4000) for precise application control.
  • Built-in digital filter function to suppress high-frequency process noise.
  • Peak hold and valley hold functions for tracking transient process limits.
  • Disconnection detection feature for 1 to 5 V and 4 to 20 mA input signals.

Applications

  • Multi-zone temperature tracking and monitoring in thermal processing.
  • Flow rate, level, and pressure transmitter integration in water treatment systems.
  • Feedback control loops in plastic extrusion and chemical dosing machinery.
  • Factory automation and process monitoring systems requiring high-density analog acquisition.

Technical Specifications

ManufacturerPart Number/ModelSeriesModule TypeNumber of InputsInput Ranges (Voltage)Input Ranges (Current)Input Impedance (Voltage)Input Impedance (Current)ResolutionConversion SpeedAccuracy (at 25 degC)IsolationExternal ConnectionsCurrent ConsumptionDimensionsWeightOperating Temperature
Omron
CJ1W-AD081-V1
CJ Series (CJ1, CJ2)
Analog Input Unit (Special I/O Unit)
8 points
1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V
4 to 20 mA
1 MOhm minimum
250 Ohm rated resistance
1/4000 (standard mode), 1/8000 (high-resolution mode)
250 microseconds/point max.
Voltage: +/-0.2% of F.S. | Current: +/-0.4% of F.S.
Photocoupler isolation between input terminals and PLC internal bus (no isolation between individual input channels)
18-point terminal block (detachable)
420 mA max. at 5 VDC (supplied via backplane)
31 mm x 90 mm x 89 mm (W x H x D)
150 g (excluding shipping packaging)
0 to 55 degC

Connections and Interfaces

The unit features an 18-point detachable terminal block. Users can pre-wire the block before attaching it to the module. Terminal mappings should follow standard instrumentation wiring layouts:

Terminal Pair Signal Designation Description
A1 / B1 V IN 1 / I IN 1 Input 1 Voltage (+) / Input 1 Current (+)
A2 / B2 COM 1 Input 1 Common (-)
A3 / B3 V IN 2 / I IN 2 Input 2 Voltage (+) / Input 2 Current (+)
A4 / B4 COM 2 Input 2 Common (-)
A5 / B5 V IN 3 / I IN 3 Input 3 Voltage (+) / Input 3 Current (+)
A6 / B6 COM 3 Input 3 Common (-)
A7 / B7 V IN 4 / I IN 4 Input 4 Voltage (+) / Input 4 Current (+)
A8 / B8 COM 4 Input 4 Common (-)
A9 / B9 NC / SLD No Connection / Shield Ground Terminal

Note: Terminals A10 through B18 follow a repeating functional layout for Inputs 5 through 8. When using current inputs, short-circuit the voltage input (V IN) and current input (I IN) terminals for that channel.

Installation Guidelines

  • Always switch off the PLC system power supply before mounting or removing the module from the rack.
  • Ensure the slide locks on the top and bottom of the unit are securely locked into the adjacent modules.
  • To prevent electromagnetic interference, use shielded twisted-pair (STP) cables for all analog signal runs.
  • Route analog I/O wiring separately from high-voltage, high-current AC power cables.
  • Connect the shield wire of the input cables to the shield terminal (SLD) or ground them at the panel entry point.

Compliance and Certifications

  • CE Mark Directive compliant
  • UL and cULus listed
  • Lloyd's Register approved for marine installations

What is the conversion speed of the CJ1W-AD081-V1?

The module features a fast conversion speed of 250 microseconds per point, meaning all 8 channels can be processed in 2 milliseconds.

Can I mix voltage and current input signals on the same CJ1W-AD081-V1 unit?

Yes. Each of the 8 channels can be configured independently for voltage or current input types using the PLC software settings.

How do I wire a current input channel instead of a voltage input?

To configure a channel for current input (4 to 20 mA), you must short-circuit the Voltage Input (V IN) and Current Input (I IN) terminals for that specific channel, then connect the signal source to these combined terminals and the common (COM) terminal.

Does this module require an external power supply?

No. The CJ1W-AD081-V1 draws its operational power directly from the 5 VDC internal bus of the CJ-series PLC backplane.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...