1 z 1

Omron E5CC-RX0ASM-000 E5CC Digital Temperature Controller

Omron E5CC-RX0ASM-000 E5CC Digital Temperature Controller

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: E5CC-RX0ASM-000

  • Country of origin:Japan

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 130g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Managing precise thermal profiles in demanding processing environments is the primary function of the Omron E5CC-RX0ASM-000 digital temperature controller. Operating with an ultra-fast 50 ms input sampling period, this instrument executes real-time control loop adjustments to stabilize dynamic systems. It features a high-contrast dual display for clear visibility of Process Value (PV) and Set Value (SV) parameters, making it an essential component for critical industrial machinery. Designed with a shallow housing depth to minimize panel space requirements, this unit handles universal thermal inputs with high accuracy, ensuring reliable operational repeatability.

Key Features

  • High-Speed Sampling: Rapid 50 ms sampling cycle captures micro-thermal deviations instantly.
  • Universal Input Compatibility: Direct integration with thermocouples, platinum resistance thermometers, and standard analog linear signals.
  • Compact Housing Profile: Panel-mount configuration requires minimal enclosure depth, maximizing internal wiring space.
  • Multi-Status Display: Clear digital readouts provide real-time diagnostic and process feedback directly on the front interface.

Applications

  • Packaging machinery sealing-jaw thermal regulation.
  • Plastics extrusion and injection molding barrel zone controls.
  • Industrial heat-treatment chambers and laboratory ovens.
  • Food pasteurization and high-accuracy liquid processing operations.

Technical Specifications

Manufacturer Omron
Model / SKU E5CC-RX0ASM-000
Product Series E5CC Series
Product Type Digital Temperature Controller
Input Sampling Period 50 ms
Thermocouple Accuracy (plus/minus 0.3% of PV or plus/minus 1 degC, whichever is greater) plus/minus 1 digit max.
RTD Input Accuracy (plus/minus 0.2% of PV or plus/minus 0.8 degC, whichever is greater) plus/minus 1 digit
Analog Input Accuracy plus/minus 0.2% FS plus/minus 1 digit max.
Current Transformer (CT) Input Accuracy plus/minus 5% FS plus/minus 1 digit max.
Transfer Output Accuracy plus/minus 0.3% FS max
Remote SP Input Accuracy plus/minus 0.2% FS plus/minus 1 digit max
Net Weight 0.13 kg
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing older legacy controllers such as the Omron E5CN series, verify depth clearances. The E5CC series features a shallow 60 mm body behind the panel, which is significantly smaller than previous configurations. Program parameters can be migrated seamlessly via CX-Thermo software, eliminating the need for manual code translation.

Application Pitfalls & Engineering Notes

Because of the rapid 50 ms sampling rate, high-gain PID configurations may exhibit oscillations if there is physical thermal lag between the heating element and the sensor probe. Running the auto-tuning sequence at normal system operating temperatures rather than cold-starting the process minimizes integral windup risk.

Commissioning & Wiring Tips

Thermocouple extension wires must be routed completely isolated from high-voltage AC lines to avoid electromagnetic interference. Ensure that rear terminal connection screws are torqued exactly to manufacturer specifications to maintain solid contact points, as loose connections will induce cold-junction compensation measurement errors.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and lock out all electrical power sources supplying the control cabinet prior to beginning hardware installation. Ensure the system has fully discharged any capacitive voltage to prevent electrical shock. Verify physical layout dimensions and panel cutouts prior to securing the controller brackets.

1
Insert the controller housing through the standard DIN panel cutout from the front face.
2
Slide the mounting fixture along the housing body from the rear of the panel until it locks tightly against the panel inner wall.
3
Terminate field power and sensor wiring to the rear terminals using insulated crimp terminals, ensuring clean wire separation.

What is the sampling rate of the E5CC-RX0ASM-000?

The unit features a high-speed input sampling period of 50 ms, enabling rapid feedback loops and stable process temperature regulation.

What sensor inputs does this Omron temperature controller accept?

This controller supports universal inputs including standard thermocouples, platinum resistance thermometers (RTDs), and analog linear signals.

How can I avoid cold-junction measurement errors during installation?

Keep all thermocouple sensor wiring physically separated from high-current power cables, and torque the terminal screws precisely to prevent thermal drift.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...