1 z 1

Omron K3HB-RNB-C2 K3HB Series Digital Rotary Pulse Indicator

Omron K3HB-RNB-C2 K3HB Series Digital Rotary Pulse Indicator

Only 8 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: K3HB-RNB-C2

  • Country of origin:Japan

  • Product Type: Digital Rotary Pulse Indicators

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Engineered for high-speed rotational measurement, the Omron K3HB-RNB-C2 serves as a highly precise digital rotary pulse indicator within demanding industrial automation frameworks. Designed to support rotary pulse inputs up to 50 kHz, this device provides instantaneous, high-resolution velocity and rotation metrics. The unit integrates an NPN/voltage pulse sensor input configuration and utilizes four independent SPST-NO relay outputs for critical limit monitoring (HH, H, L, LL). Its multi-color display dynamically changes color based on alarm status, providing field operators with immediate visual confirmation of system performance.

Features

  • High-Speed Pulse Processing: Capable of accurate signal evaluation up to 50 kHz for rapid shaft rotation and line speed monitoring.
  • Versatile Sensor Input: Designed to interface natively with NPN open-collector or voltage pulse sensors.
  • Quad Limit Relay Outputs: Provides dedicated SPST-NO contacts for High-High (HH), High (H), Low (L), and Low-Low (LL) limit controls.
  • Dynamic Visual Feedback: Visual alert status communicated through a dual-color process value display.
  • Robust Environment Adaptation: Engineered to maintain operations in ambient temperatures ranging from -10 to 55 degC.

Applications

  • Rotational speed (RPM) monitoring of industrial electric motors and turbines.
  • Conveyor line velocity tracking and throughput measurement in packaging systems.
  • Flow meter pulse integration for volumetric rate monitoring.
  • Operational safety interlock systems requiring overspeed or underspeed trip detection.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Omron
Model Number K3HB-RNB-C2
Product Series K3HB Series
Input Sensor Code NB (NPN input / voltage pulse input)
Relay Output Configuration C2 (Relay contact: HH, H, LL, L; SPST-NO each)
Nominal Supply Voltage 100 to 240 VAC
Maximum Measurement Frequency 50 kHz
Ambient Operating Temperature -10 to 55 degC (no icing or condensation)
Ambient Operating Humidity 25% to 85% RH
Storage Temperature Range -25 to 65 degC
Maximum Operating Altitude 2000 m
Device Base Weight Approx. 300 g
Shipping Weight (Calculated) 1.5 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The K3HB series serves as the modern standard update to legacy Omron K3N indicators. While functional similarities exist, please note that wiring structures and rear terminal blocks differ significantly. Panel cutouts are standardized, but back-of-panel depth clearances must be verified during system retrofits to accommodate the output terminal configuration on the K3HB-RNB-C2.

Application Pitfalls & Engineering Notes

When utilizing the maximum 50 kHz measurement range, standard sensor wiring is highly susceptible to electromagnetic interference (EMI). Run signal lines in independent, grounded steel conduits separate from high-current motor leads or Variable Frequency Drive (VFD) output cables to prevent false triggering. Keep the cable length to the sensor as short as possible to prevent signal attenuation.

Commissioning & Wiring Tips

Ensure that the internal parameter settings match the connected sensor type (NPN open-collector versus voltage pulse). Failing to configure this software parameter correctly may result in zero pulse registration or risk overloading the internal signal pull-up circuit. Always apply shielded twisted-pair (STP) cabling for the input connections.

Installation Guidelines

CRITICAL WARNING: Prior to wiring or mounting the K3HB-RNB-C2 unit, verify that all incoming AC power distribution sources are physically locked out and tagged out. Hazardous voltages remain present on terminal contacts during operation. Do not touch terminals while supply power is active.
1

Prepare a standardized 1/8 DIN panel cutout (92 mm x 45 mm) and slide the unit through the panel front, ensuring the rubber sealing gasket is flat against the surface.

2

Secure the unit into the panel using the provided side mounting fixtures, tightening the screws evenly to ensure a secure dust and water-resistant fit.

3

Attach the sensor input cables to the designated NB terminals using properly sized crimped ferrule connectors to ensure permanent gas-tight contacts.

4

Connect the 100 to 240 VAC power line to the primary power input terminals, re-check terminal polarity, and proceed to device parameter configuration.

What sensor types are compatible with the NB input on the K3HB-RNB-C2?

The NB input code signifies compatibility with NPN open-collector transistors and solid-state voltage pulse sensors.

Can the C2 relay output block be configured for NC operation?

No, the C2 output board features four independent SPST-NO (normally open) relay contacts for the HH, H, L, and LL alarm thresholds.

What is the maximum operating frequency of this rotary pulse meter?

The K3HB-RNB-C2 is rated for high-speed measurement applications up to a maximum input frequency of 50 kHz.

What is the standard operating voltage for this unit?

This model is designed to operate on a standard power supply range of 100 to 240 VAC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizace HMI Bailey INFI 90 Symphony běžících na OpenVMS Alpha

Praktický průvodce výměnou zastaralých operátorských stanic Bailey Symphony běžících na OpenVMS Alpha. Porovnává emulaci Alpha, migraci OpenVMS na x86, přemostění OPC a postupnou modernizaci ABB.

Proč jsou údaje o údržbě nezbytné pro průmyslovou spolehlivost

Údaje o údržbě propojují pracovní příkazy, signály ze senzorů, historii majetku, náklady a znalosti techniků. Správné využití těchto dat zlepšuje plánování, spolehlivost, prediktivní údržbu, kontrolu...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...