1 z 1

Omron NX-AD2204 Analog Input Unit

Omron NX-AD2204 Analog Input Unit

Only 2 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-AD2204ÿ

  • Country of origin:Japan

  • Product Type: Analog Input Unit

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The NX-AD2204 is a high-precision Analog Input Unit from Omron’s NX series. Designed for modular integration, it is widely used in factory automation systems to convert real-world analog signals (such as voltage or current from sensors) into high-resolution digital values that the PLC system can process.

As part of the NX-series I/O family, the NX-AD2204 is designed for high-speed, synchronized communication with the EtherCAT network, making it an excellent choice for distributed I/O architectures where low-latency data acquisition is critical for process control and machine monitoring.

Features

  • Series: Omron NX Series
  • Type: Analog Input Unit
  • Integration: Seamless connectivity within the NX-series I/O system
  • Precision: High-resolution signal conversion for accurate data acquisition
  • Application: Ideal for distributed I/O environments and EtherCAT-based automation architectures

Applications

  • Temperature, pressure, and flow monitoring
  • Industrial process control loops
  • Data acquisition for machinery performance tracking
  • Integration with analog sensors in high-speed production lines

Technical Specifications

Feature Specification
Manufacturer Omron
Brand Omron
Series NX Series
Model NX-AD2204
Product Type Analog Input Unit
Shipping Weight 1.0 kg

Installation Guidelines

  • Mounting: Mount the unit on a DIN rail as part of an NX-series I/O station. Ensure that the unit is properly clicked into the neighboring I/O modules to maintain the internal bus connection.
  • Wiring: Use shielded, twisted-pair cabling for analog signal transmission to mitigate the risk of electromagnetic interference (EMI). Ground the cable shield properly at the designated terminal point.
  • Configuration: Configure the input range and filter settings using the Sysmac Studio software to match your specific sensor requirements (e.g., 4-20mA or 0-10V).
  • Power: Ensure the 24V DC power supply for the I/O terminal is stable and adheres to the specifications to avoid measurement instability.

What is the primary role of the NX-AD2204?

It serves as an analog input module to acquire and convert analog signals from sensors into digital data for processing within an Omron PLC system.

Is the NX-AD2204 designed for specific network types?

Yes, it is part of the Omron NX-series I/O family, which is optimized for EtherCAT network architectures.

What software is used to configure this unit?

The module is typically configured using Omron's Sysmac Studio software.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Japan
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...