1 z 1

Omron NX-ECC201 EtherCAT Coupler Unit

Omron NX-ECC201 EtherCAT Coupler Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-ECC201

  • Country of origin:Japan

  • Product Type: EtherCAT Coupler Unit

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The NX-ECC201 is a high-performance EtherCAT Coupler Unit designed to serve as the gateway between an EtherCAT network and the Omron NX-series I/O family. This unit enables seamless, high-speed communication between a master controller (such as an Omron NJ/NX machine automation controller) and distributed I/O modules, allowing for modular, scalable machine architectures.

With a compact width of 46 mm, the NX-ECC201 manages the local power supply and communication for connected NX units, ensuring synchronized data exchange across the EtherCAT network. It supports a rated voltage of 24 VDC for the unit power supply and provides robust power distribution for connected I/O, supporting up to 4A for the I/O power supply.

Features

  • Network Protocol: EtherCAT (high-speed, real-time industrial Ethernet)
  • Integration: Central hub for modular NX-series I/O modules
  • Power Management: Manages local unit power (24 VDC) and distributed I/O power (5–24 VDC, 4A max)
  • Synchronization: Supports high-speed, deterministic data exchange for motion and process control
  • Design: Slim 46 mm width for space-efficient cabinet mounting

Applications

  • Distributed I/O systems for multi-axis motion control
  • High-speed manufacturing and packaging lines
  • Integrated plant-wide data acquisition
  • Modular machine designs requiring easy expansion

Technical Specifications

Feature Specification
Manufacturer Omron
Model NX-ECC201
Product Type EtherCAT Coupler Unit
Width 46 mm
NX Unit Power Supply 24 VDC (10 W max)
I/O Power Supply 5–24 VDC (4A max)
Weight 0.17 kg

Installation Guidelines

  • Mounting: Snap the coupler onto a standard 35 mm DIN rail. Ensure the connection pins on the side are aligned to facilitate communication with the first NX-series I/O module.
  • Network Wiring: Use shielded Category 5e (or higher) Ethernet cables to ensure reliable communication in high-EMI industrial environments.
  • Power Supply: Use a dedicated, stable 24 VDC power supply for the NX Unit and ensure the I/O power supply meets the specific requirements of the connected sensors and actuators.
  • Configuration: Integrate the coupler into your EtherCAT network using the Sysmac Studio software to map I/O data and ensure the bus configuration is validated.

What is the primary role of the NX-ECC201?

The NX-ECC201 functions as a communications gateway, connecting the EtherCAT network to a modular stack of Omron NX-series I/O modules.

What power capabilities does this coupler provide?

It provides power to the connected NX-series I/O units (10W max) and can handle up to 4A for the I/O power supply circuit.

Which software is required to configure the NX-ECC201?

Omron's Sysmac Studio software is typically used to configure, map, and troubleshoot the EtherCAT coupler and its connected I/O units.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...