1 z 1

Omron NX-TS3204 NX Series Temperature Input Unit

Omron NX-TS3204 NX Series Temperature Input Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-TS3204

  • Country of origin:Japan

  • Product Type: Temperature Input Units

  • Payment: T/T, Western Union

  • Weight: 130g

  • Dimensions: 24 (W) x 100 (H) x 71 (D) mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Optimized for high-speed, high-density thermal monitoring, the Omron NX-TS3204 is a 4-point temperature input unit designed for direct integration within NX-series PLC backplanes and distributed I/O couplers. This unit provides dedicated interface circuitry for resistance thermometers (RTDs), allowing precise calibration and temperature feedback across demanding industrial automation systems. Featuring channel-to-channel isolation and a robust, high-resolution ADC architecture, it protects vulnerable signal loops from high common-mode voltages and electrical noise common in heavy industrial facilities.

Features

  • 4 Independent Channels: Connects up to four RTD sensors to a single space-saving slice module.
  • Multi-Sensor Support: Built-in compatibility with three-wire Pt100 and Pt1000 resistance thermometers.
  • High-Speed Processing: Extremely fast input conversion time of 60 ms per unit ensures real-time thermal loop response.
  • Ultra-High Resolution: Achieves a maximum tracking resolution of 0.001 degC for critical process variables.
  • Full Electrical Isolation: Double-isolated architecture utilizing internal transformers and digital isolators between the inputs, the NX bus, and neighboring channels.
  • Toolless Termination: Features Omron push-in screwless clamping terminals for secure and vibration-resistant wiring.

Applications

  • Dynamic heat-sealing control in high-speed packaging machinery.
  • Multi-zone temperature tracking in plastic extrusion and molding profiles.
  • Precise thermal environment monitoring in climate test chambers and cleanrooms.
  • Critical pasteurization and thermal processing control in food and beverage production.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Code NX-TS3204
Module Type Temperature Input Unit (Resistance Thermometer)
Number of Inputs 4 channels
Compatible Sensors Pt100 (3-wire), Pt1000 (3-wire)
Conversion Time 60 ms / Unit
Measurement Resolution 0.001 degC max.
Input Detection Current Approx. 0.25 mA
Conductor Resistance Effect 0.06 degC/Ohm max. (Maximum allowable resistance: 20 Ohm)
I/O Refreshing Method Free-Run refreshing
Isolation Method Transformer (Power), Digital Isolator (Signal) between inputs and NX bus, plus channel-to-channel
Dielectric Strength 510 VAC for 1 minute between isolated circuits (leakage current 5 mA max)
NX Unit Power Consumption 1.45 W max. (CPU/CCU link); 1.05 W max. (Communications Coupler)
Physical Dimensions 24 mm (W) x 100 mm (H) x 71 mm (D)
Weight 0.13 kg (Net)

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-TS3204 slice integrates into both local Sysmac NX1P2 / NX102 controller structures and remote I/O nodes via EtherCAT (NX-ECC) or EtherNet/IP (NX-EIC) couplers. Unlike 2-point temperature units (such as the NX-TS2204), this 4-point design utilizes high-density 16-point push-in connectors in double rows, allowing tight DIN-rail spacing but requiring carefully planned routing for the incoming sensor cables.

Application Pitfalls & Engineering Notes

To maintain the native high accuracy of 0.001 degC, engineers must avoid asymmetric wiring resistances. While 3-wire RTDs compensate for equal line resistance, mismatched conductor resistances between the A and B/B' legs directly generate measurement offsets. Keep individual lead-wire resistances strictly below 20 Ohms, and route the signal lines away from large variable frequency drives (VFDs) and high-current motor control circuits to prevent EMI-induced drift.

Commissioning & Wiring Tips

This module relies on a warm-up period of 30 minutes before system calibration routines are initiated. When connecting solid wires or stranded wires with ferrules, simply push the wire directly into the terminal without opening the clamp with a tool. When commissioning through Sysmac Studio, ensure the input filter parameters and the target sensor type (Pt100 or Pt1000) are explicitly defined in the Unit Operation Settings, as mismatched configurations will generate erratic temperature values or fault indicators.

Installation Guidelines

CRITICAL WARNING: Completely de-energize the entire control panel, including the NX-series CPU and auxiliary external power sources, before mounting, removing, or wiring the module. Working on live systems may destroy internal sensitive digital isolators or trigger unexpected controller system errors.
1

Align the NX-TS3204 unit slide-guides with the adjacent module or bus coupler on the 35mm DIN rail.

2

Firmly slide the module until the integrated locking mechanism engages with the DIN rail with an audible click.

3

Strip the temperature sensor cables to 8-10 mm or crimp them with suitable ferrules, then insert them directly into the front-facing screwless terminal block.

4

Double-check that the field shield ground is properly clamped to the functional ground strip below the DIN rail line.

Which temperature sensors are compatible with the NX-TS3204 module?

The module natively supports Pt100 and Pt1000 three-wire resistance thermometers (RTDs).

What is the update rate and measurement resolution of this input unit?

It features a fast conversion time of 60 ms per unit with an ultra-precise temperature resolution limit of 0.001 degC.

Does the unit require an external I/O power supply?

No, it features a no-supply design and consumes current exclusively from the NX Unit power supply lines on the backplane bus.

How are the sensor channels isolated from electrical interference?

The module uses transformer isolation for power lines and digital isolators for signal paths. This isolation exists both between the inputs and the NX bus, and individually between each input channel.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...