Providing high-density analog signal generation for precise process control, the Schneider Electric TSXASY800 integrates directly into Modicon Premium backplane architectures. This premium analog output module delivers eight individually configurable channels, allowing industrial operators to interface seamlessly with variable speed drives, control valves, actuators, and external instrumentation. Engineered for high-reliability environments, the module ensures stable signal conversion and robust isolation between channels and the internal bus.

Key Features

  • Eight Independent Channels: Individually configurable outputs maximize slot density and system flexibility.
  • Multirange Compatibility: Supports standard industrial voltage and current signal ranges on a per-channel basis.
  • Modicon Premium Integration: Direct bus connection with hot-swapping capabilities supported by compatible rack configurations.
  • High-Resolution Conversion: Ensures precise control loop execution with minimal signal drift over temperature variations.
  • LED Diagnostics: Front-panel status indicators provide rapid visual feedback on module health and channel faults.

Applications

  • Modulating Actuator Control: Positioning of dampers, control valves, and guide vanes in heavy industrial processes.
  • Speed Reference Distribution: Sending precise analog speed setpoints to variable frequency drives (VFDs).
  • Process Retransmission: Routing internal controller variables to analog chart recorders, panel meters, or legacy SCADA interfaces.
  • Water and Wastewater Treatment: Controlling chemical dosing pumps and flow-regulating valves.

Technical Specifications

Manufacturer Schneider Electric
Model / SKU TSXASY800
Product Series Modicon Premium
Module Type Analog Output Module
Number of Outputs 8
Output Range Types Multirange (Voltage and Current)
Product Phase Phase-Out (Legacy Support Available)
Commodity Code 85389091
Shipping Weight (Calculated) 0.50 kg
Package Dimensions (Calculated) 15.20 x 12.70 x 5.10 cm

Empirical Engineering Insights

Alternative Models & Compatibility

The TSXASY800 is native to the Modicon Premium platform and requires PL7 Pro or EcoStruxure Control Expert (formerly Unity Pro) for hardware catalog configuration. When migrating legacy systems to Modicon M580 architectures, this module cannot be directly inserted into Ethernet RIO (eX80) drops without a dedicated Premium-to-M580 upgrade adapter or complete I/O replacement.

Application Pitfalls & Engineering Notes

Ensure that the external 24VDC loop power supply is highly regulated and free of high-frequency noise. Common-mode voltage limits must be strictly observed; if the potential difference between channel grounds exceeds the module's isolation rating, cross-channel interference or hardware damage may occur. Always use external isolation barriers when routing signals to field devices with independent, ungrounded power systems.

Commissioning & Wiring Tips

Always use shielded twisted-pair (STP) cabling for all analog output connections. Ground the cable shields at the rack side only to prevent ground loops. When configuring the module in software, verify that unused channels are explicitly disabled or shorted to prevent floating channel errors and diagnostic LED faults.

Installation Guidelines

CRITICAL WARNING: HAZARD OF ELECTRIC SHOCK OR ARC FLASH

Disconnect all power sources supplying the PLC rack and external loop power before attempting to install, remove, or wire the TSXASY800 module. Verify that no residual voltage is present on the field wiring terminals. Failure to follow these safety protocols can result in severe equipment damage, personal injury, or death.

1

Ensure the rack power supply is switched off. Align the module with the target slot on the Modicon Premium backplane.

2

Gently slide the module into the slot guides until the rear connectors are fully seated in the backplane. Secure the module locking mechanism.

3

Connect the pre-wired terminal block to the front of the module, ensuring the locking screws or latches are fully engaged to prevent intermittent connections.

4

Apply power to the rack, download the hardware configuration from your programming environment, and verify that the module's RUN LED illuminates green.

What software is required to configure the TSXASY800 module?

The TSXASY800 is configured using PL7 Pro or EcoStruxure Control Expert (formerly Unity Pro), where each of the 8 channels can be individually set for voltage or current ranges.

Does the TSXASY800 require an external power supply for current loops?

Yes, an external 24VDC power supply is typically required to power the analog output loops, depending on the channel configuration and load impedance.

Can channels on the TSXASY800 be configured for different signal ranges simultaneously?

Yes, the TSXASY800 is a multirange module, allowing individual channel configuration for different voltage (e.g., +/-10V, 0-10V) or current (e.g., 4-20mA) ranges.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...