1 z 7

Siemens 6ES7414-3XJ04-0AB0 SIMATIC S7-400 CPU 414-3

Siemens 6ES7414-3XJ04-0AB0 SIMATIC S7-400 CPU 414-3

Only 3 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7414-3XJ04-0AB0

  • Country of origin:Germany

  • Product Type: Standard CPUs

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 900g

  • Dimensions: 5.10cm x 22.90cm x 30.50cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

The 6ES7414-3XJ04-0AB0 is a Central Processing Unit (CPU 414-3) from the SIMATIC S7-400 automation series. This unit is engineered to manage complex control tasks in demanding industrial applications, providing high performance and scalability. It features a total work memory of 1.4 MB, partitioned into 700 KB for program code and 700 KB for data, ensuring efficient execution of automation logic and storage of process variables.

Features

  • Work Memory: 1.4 MB total (700 KB code / 700 KB data)

  • Interface 1: MPI/DP interface (up to 12 Mbit/s)

  • Interface 2: PROFIBUS DP interface

  • Interface 3: Slot for plug-in IFM (Interface Module) for flexible expansion

  • Platform: SIMATIC S7-400

Applications

  • High-end automation and control systems

  • Large-scale manufacturing and process control

  • Distributed I/O system management

  • Complex industrial automation networks

Technical Specifications

Feature Specification
Manufacturer Siemens
Range SIMATIC S7-400
Product Type Standard CPUs
Work Memory 1.4 MB (700 KB code / 700 KB data)
Dimensions 5.10 x 22.90 x 30.50 cm
Weight 0.90 kg
Commodity Code 85389091
Product Phase Obsolete
Successor Model 6ES7414-3XM05-0AB0

Installation Guidelines

  • Rack Mounting: Insert the CPU into the designated central rack slot. Ensure the backplane connectors are fully engaged to establish a secure system bus connection.

  • Power Supply: Ensure the CPU is powered by an appropriate S7-400 power supply module mounted in the same rack.

  • Interfaces: Configure the MPI/DP and PROFIBUS interfaces using the appropriate software tools. Ensure the IFM module is properly seated in the third interface slot if required for specific communication tasks.

  • Cooling: Maintain sufficient vertical clearance above and below the rack to allow for proper convection cooling of the CPU and associated modules.

  • Grounding: Connect the CPU rack to a common functional earth to minimize electrical noise and ensure reliable signal integrity.

What is the memory capacity of this S7-400 CPU?

The CPU 414-3 has a total work memory of 1.4 MB, split into 700 KB for code and 700 KB for data.

What communication interfaces are supported?

It includes an MPI/DP interface, a PROFIBUS DP interface, and a third interface for a plug-in IFM module.

What is the successor for this CPU?

The successor model is the 6ES7414-3XM05-0AB0.

What is the product lifecycle status?

This module is classified as Obsolete.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...