1 z 1

Siemens 6ES7716-2CA11-0CD4 SIMATIC Field PG M4 Industrial Programming Device

Siemens 6ES7716-2CA11-0CD4 SIMATIC Field PG M4 Industrial Programming Device

Only 2 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2CA11-0CD4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The Siemens 6ES7716-2CA11-0CD4 is a SIMATIC Field PG M4 Premium plus/SSD industrial programming device, offered as a promotional package. This robust engineering tool is equipped with a 300 GB SATA Solid-State Drive (SSD), providing fast and reliable storage for industrial software and project files. It features a 15.6-inch Full HD display (1920x1080) for clear visualization of engineering environments and a QWERTY keyboard (with German layout option). The device comes pre-installed with Windows 7 Ultimate SP1, 64-bit, and is configured with 2x 8 GB RAM for efficient multitasking. It includes an MPI cable and licenses for essential Siemens engineering software: STEP 7 Professional V13 and WinCC Advanced V13, making it ready for immediate use in PLC and HMI programming tasks. This specific configuration does not include an S5 interface or S5-EPROMMER functionality, and is supplied with a power supply cable suitable for the UK.

Features

  • Promotional package for SIMATIC Field PG M4 Premium plus/SSD
  • Integrated 300 GB SATA Solid-State Drive (SSD)
  • 15.6-inch Full HD display (1920x1080 resolution)
  • QWERTY keyboard with German layout support
  • Pre-installed Windows 7 Ultimate SP1, 64-bit operating system
  • 16 GB RAM (2x 8 GB modules)
  • Includes MPI communication cable
  • Licensed for Siemens STEP 7 Professional V13
  • Licensed for Siemens WinCC Advanced V13
  • Excludes S5 interface and S5-EPROMMER
  • Supplied with power supply cable for UK

Applications

The Siemens 6ES7716-2CA11-0CD4 SIMATIC Field PG M4 is designed for a wide range of industrial automation applications, including:

  • Commissioning and maintenance of SIMATIC S7 PLCs and HMI systems.
  • Programming, configuration, and diagnostics for automation projects.
  • On-site troubleshooting and system optimization in industrial environments.
  • Development and testing of control programs and visualization projects.
  • Data acquisition and analysis in manufacturing and process control.

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG M4
Type of Product Premium Industrial Programming Device
Product Phase Phase-Out
Storage 300 GB SATA Solid-State Drive (SSD)
Display 15.6" Full HD (1920x1080)
Keyboard QWERTY (& German)
Operating System Windows 7 Ultimate SP1, 64-bit
RAM 16 GB (2x 8 GB)
Included Software Licenses STEP 7 Professional V13, WinCC Advanced V13
Included Cables MPI cable, Power supply cable for UK
S5 Interface Without
S5-EPROMMER Without
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

When deploying the SIMATIC Field PG M4, observe the following guidelines for optimal performance and safety:

  1. Power Connection: Connect the Field PG to a suitable power outlet using the provided UK power cable. Ensure the power supply meets the device's requirements.
  2. Environmental Considerations: Operate the device within specified temperature and humidity ranges for industrial equipment. Avoid exposure to excessive dust, moisture, or direct sunlight.
  3. Network Connections: Utilize the integrated communication interfaces (e.g., MPI) to connect to SIMATIC automation systems. Ensure proper cable routing and secure connections.
  4. Software Configuration: While essential software is pre-installed, verify the correct version and configuration of STEP 7 Professional V13 and WinCC Advanced V13 for your specific automation projects.
  5. Data Backup: Regularly back up project data and system configurations to external storage to prevent data loss.
  6. Security: Implement appropriate security measures, including strong passwords and network segregation, when connecting to industrial control networks.

What is the primary purpose of the Siemens 6ES7716-2CA11-0CD4?

It is an industrial programming device designed for commissioning, maintenance, and diagnostics of SIMATIC S7 PLCs and HMI systems in industrial environments.

What operating system and software licenses are pre-installed?

The device comes with Windows 7 Ultimate SP1 (64-bit) and includes licenses for STEP 7 Professional V13 and WinCC Advanced V13.

Does this Field PG M4 support S5 automation systems?

No, this specific configuration is explicitly stated to be without an S5 interface and without an S5-EPROMMER.

What are the main hardware specifications of this Field PG?

It features a 15.6-inch Full HD display, a 300 GB SATA Solid-State Drive (SSD), and 16 GB of RAM (2x 8 GB).

Is an MPI communication cable included with the device?

Yes, an MPI cable is included, facilitating direct connection to SIMATIC automation systems.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...