1 z 1

Triconex 3351 Trident Analog Input Module

Triconex 3351 Trident Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: Triconex

  • Product No.: 3351

  • Country of origin:United States

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The Triconex 3351 is a reliable hardware assembly designed for fault-tolerant operation within the Trident safety system architecture. As a dedicated Analog Input Module, this unit provides the essential data acquisition layer for low point counts and distributed industrial safety networks. To enforce the highest level of continuous operation, each module is engineered with three isolated channels that independently process analog inputs received from field devices. Every individual channel securely transmits its processed input variables directly to the specific Main Processor (MP) associated with that channel loop. The system MPs vote the data automatically before passing it to the safety application, eliminating any single point of failure in critical process variables.

Features

  • Equipped with three distinct isolated channels to preserve complete loop independence
  • Processes incoming analog signal values directly from connected field devices
  • Operates seamlessly with the system Main Processors using automated hardware voting mechanisms
  • Fits perfectly into low point count configurations and distributed system topologies

Applications

  • Emergency Shutdown (ESD) architectures
  • Burner Management Systems (BMS)
  • Fire and Gas (F&G) protective control systems
  • Distributed fault-tolerant safety monitoring

Ordering Information

The component is available within multiple standard system packages:

Model Product Name Qty Description Consists of
5351 Analog Input TriPak

1


 

1

Analog Input Module


 

Analog Input Baseplate Kit

3351


 

2351

5352 Analog Input Tripak (RTD/TC/4-20 mA)

1


 

1

Analog Input Module


 

Analog Input Baseplate (RTD/TC/4-20 mA)

3351


 

2352

Technical Specifications

Mechanical Characteristics

Parameter Value
Manufacturer Triconex
Model 3351

Channel Capacities

Parameter Value
Isolated Channels 3 channels per module
System Compatibility Trident Distributed I/O System

Installation Guidelines

  • Module Placement: Seat the 3351 module onto the appropriate connectors of an approved 2351 or 2352 baseplate structure within the column configuration.
  • Environmental Shielding: Ensure that all unused or exposed baseplate slots are protected using the standard 2900 slot covers to keep components safe from dust and liquids.
  • Unwired Contact Guarding: Mount proper 2901 terminal covers over any open terminals that are not actively connected to live field wiring paths.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Triconex 3351 Trident Analog Input Module

How does the module ensure accurate signal reading for critical safety software?

The module uses three isolated channels to capture data from field devices and sends the inputs to matching Main Processors, which vote the data before passing it to the application.

Which standard baseplate kits are explicitly compatible with this module?

This module is designed to fit onto the 2351 Analog Input Baseplate Kit or the 2352 Analog Input Baseplate Kit for TC, RTD, and 4-20mA signals.

What standard accessories are necessary to protect the baseplate connectors during operation?

Accessories such as slot covers, terminal covers, and end caps are necessary to fully protect the active and inactive sections from dust and ambient liquids.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...