1 z 3

UR7BH GE Multilin UR-7BH Universal Relay Communication Module

UR7BH GE Multilin UR-7BH Universal Relay Communication Module

Only 3 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-7BH

  • Country of origin:United States

  • Product Type: Communication Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 660g

  • Dimensions: 16.3cm x 4.2cm x 21cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

The UR 7BH (also identified as UR-7BH) is a dedicated fiber-optic communication interface module manufactured by General Electric for the Multilin Universal Relay series protection and control platform. This module serves as a localized data transmission interface, enabling high-speed optical communications across industrial networks and substation environments. Equipped with a single-channel Edge-Emitting LED (ELED) transmitter operating at a nominal wavelength of 1300 nm, the UR 7BH is designed specifically for multi-mode fiber infrastructure. The horizontal chassis form factor, denoted by the "H" configuration suffix, allows seamless integration into horizontal UR relay slots to maintain deterministic data flow and system synchronization.

Features

  • Features a single-channel 1300 nm ELED optical transmitter configuration.
  • Designed specifically for multi-mode fiber-optic network communication architecture.
  • Integrated into the horizontal ("H") form factor for standard Universal Relay enclosures.
  • Provides high-speed data transmission path directly linked over the internal chassis backplane.
  • Delivers robust optical isolation against high-voltage electrical surges and EMI/RFI noise.

Applications

  • High-speed peer-to-peer communication between Universal Relay protection nodes.
  • Fiber-optic SCADA and substation automation network connectivity.
  • Long-distance, noise-immune communication linkages within power generation plants and industrial facilities.

Technical Specifications

Parameter Specification
Model Number UR 7BH (UR-7BH)
Product Type Communication Module (COMMS 7B)
Manufacturer GE Multilin
Wavelength 1300 nm
Fiber Type Multi-mode
Optical Source ELED, 1 Channel
Chassis Orientation Horizontal

Installation Guidelines

  • Chassis Power Down: Turn off all control voltage sources feeding the Universal Relay frame prior to handling the module to protect internal backplane chipsets.
  • Fiber Optic Care: Maintain the minimum bending radius of the multi-mode fiber patch cables to minimize attenuation. Clean the fiber ferrule tips and optical transceiver ports with lint-free wipes before connection.
  • Module Seating: Align the horizontal module carefully inside the chassis tracks, sliding it smoothly into place until the rear contact pin block locks tightly into the active backplane.
  • Network Mapping: Utilize the EnerVista UR utility program to verify device detection and map communication variables to the specific slot where the module is housed.

What type of optical fiber infrastructure is required for this module?

This module requires multi-mode fiber-optic cabling and operates at a nominal wavelength of 1300 nm.

What kind of light source does the transmitter use?

The module utilizes a 1-channel Edge-Emitting Light Emitting Diode (ELED) as its primary optical transmitter source.

Does this module require manual dip-switch network configurations upon installation?

No, hardware routing and network logic parameters are completely assigned via software using the EnerVista UR interface suite once the unit is seated in the chassis slot.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...