1 z 1

Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier

Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965350000

  • Country of origin:Germany

  • Product Type: Isolating Switch Amplifiers

  • Payment: T/T, Western Union

  • Weight: 175g

  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Množství
Zobrazit veškeré podrobnosti

Description

Designed for intrinsically safe signal processing, the Weidmuller 8965350000 functions as a high-reliability isolating switch amplifier within the ACT20X series. This module is engineered to safely isolate and transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe-area control environments. It supports inputs from NAMUR sensors or mechanical switch contacts and converts them into relay outputs.

The ACT20X-HDI-SDO-RNC-S features comprehensive galvanic isolation between the input, output, and power supply circuits, ensuring superior signal integrity and system protection. Configuration is managed via standard FDT/DTM software, allowing operators to easily set parameters, monitor device status, and configure line fault detection (LFD) for open-circuit or short-circuit conditions.

Features

  • Intrinsically safe digital inputs compatible with NAMUR sensors and mechanical switches.
  • Relay output configuration for reliable safe-area signal switching.
  • Galvanic isolation across input, output, and power supply channels.
  • Software-based configuration utilizing standard FDT/DTM tools.
  • Integrated line fault detection (LFD) to identify open and short circuits in the field wiring.
  • Compact 22.5 mm housing designed for standard DIN-rail mounting.

Applications

  • Oil and gas processing and refining facilities.
  • Chemical and petrochemical manufacturing plants.
  • Water and wastewater treatment systems.
  • Power generation and distribution utilities.
  • Hazardous area signal isolation and safety instrumented systems (SIS).

Technical Specifications

ManufacturerPart Number/ModelProduct SeriesInput TypeSensor SupplyOutput TypeNominal Switching VoltageSupply VoltagePower ConsumptionConfiguration InterfaceConnection TypeIP RatingOperating TemperatureStorage TemperatureHumidityDimensions (H x W x D)Weight
Weidmuller
8965350000 (ACT20X-HDI-SDO-RNC-S)
ACT20X
NAMUR sensor (DIN EN 60947-5-6), switch contact
8 V DC / 8 mA
Relay
<= 125 V AC / 110 V DC (safe area), <= 32 V AC / 32 V DC (Zone 2)
19.2 to 31.2 V DC
<= 1.3 W
FDT/DTM software
Screw connection
IP20
-20 to +60 Celsius
-20 to +85 Celsius
0 to 95% (non-condensing)
117.2 mm x 22.5 mm x 113.6 mm
175 g

Installation Guidelines

  • Mounting: Snap securely onto a standard TS 35 DIN rail in a vertical orientation to optimize heat dissipation.
  • Wiring Separation: Maintain a minimum physical distance of 50 mm between intrinsically safe (Ex i) field wiring and non-intrinsically safe wiring.
  • Grounding: Ensure the DIN rail is properly bonded to the functional earth ground of the control cabinet.
  • Cabinet Protection: For installation in Zone 2 environments, the module must be mounted inside an enclosure providing a minimum protection rating of IP54.

Compliance and Certifications

  • ATEX
  • IECEx
  • CE
  • UL

What is the primary function of the Weidmuller 8965350000?

The Weidmuller 8965350000 (ACT20X-HDI-SDO-RNC-S) is an intrinsically safe isolating switch amplifier designed to safely transmit digital signals from hazardous areas (such as NAMUR sensors or mechanical switches) to safe-area control systems via relay outputs.

How is the ACT20X-HDI-SDO-RNC-S configured?

This module is configured using standard FDT/DTM software, allowing operators to parameterize input types, configure line fault detection, and monitor device diagnostics.

What are the power supply requirements for this module?

The module requires a nominal supply voltage of 19.2 V DC to 31.2 V DC and has a maximum power consumption of 1.3 W.

Does the module support line fault detection?

Yes, the ACT20X-HDI-SDO-RNC-S features integrated line fault detection (LFD) to monitor the field wiring for open-circuit and short-circuit conditions.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Elektrické pohony navržené jako náhrada hydraulických systémů: Praktická příručka průmyslové automatizace

Tento článek vysvětluje, jak integrované elektrické pohony, jako je řada e-Actuator od SMC, mění průmyslové řízení pohybu nahrazením tradičních pneumatických a hydraulických systémů. Zdůrazňuje...

Matematické operace pomocí OpenPLC pro průmyslové automatizační aplikace

Tento článek vysvětluje, jak PLC systémy provádějí základní matematické operace, jako jsou sčítání, odčítání, násobení, dělení, modulo a umocňování v rámci průmyslové automatizace. Ukazuje, jak tyto...

Pokročilá Booleovská logika s programováním FBD PLC: Praktické průmyslové aplikace nad rámec základní logiky

Článek vysvětluje několik pokročilých funkcí Booleovy logiky používaných v programování PLC nad rámec základních operací AND, OR a NOT. Popisuje, jak se v diagramu funkčních bloků (FBD) využívají...

Booleovská logika v programování PLC: Pochopení logických bran FBD

Booleovská logika je základem každého programu PLC. Od jednoduchých ovládání strojů až po složité průmyslové automatizační systémy určují logické hradla, jak řadiče reagují na měnící se vstupy a...