The 2711P-RP1X is a logic module family for Allen-Bradley PanelView Plus 700 to 1500 terminals. It attaches to the rear of the display module and provides the terminal processing, memory, communication, firmware, and operating-system functions.

The logic module includes 64 MB internal CompactFlash memory and 64 MB RAM. Its external connections include an Ethernet port, a serial port, two USB ports, and a CompactFlash card slot. Status indicators provide operating information for the installed terminal.

The official installation document uses 2711P-RP1x as the family designation. Individual module revisions are identified by their series suffix.

Features

  • Designed for PanelView Plus 700 to 1500 terminals
  • 64 MB internal CompactFlash memory
  • 64 MB RAM
  • Ethernet communication port
  • Serial communication port
  • Two USB ports
  • CompactFlash card slot
  • Integrated status indicators
  • Replaceable RAM module
  • Replaceable internal CompactFlash card
  • Rear-mounted connection to the display module
  • Field-installable module construction

Applications

  • PanelView Plus terminal logic-module replacement
  • Industrial machine operator interfaces
  • Manufacturing HMI stations
  • Production-line visualization terminals
  • Process equipment operator panels
  • Existing PanelView Plus system maintenance

Technical Specifications

General

Parameter Specification
Manufacturer Allen-Bradley
Model Family 2711P-RP1x
Product Type Logic Module
Product Series PanelView Plus
Compatible Terminal Range PanelView Plus 700 to 1500
Installation Location Rear of the display module

Memory

Parameter Specification
Internal CompactFlash 64 MB
RAM 64 MB
RAM Type SODIMM RAM
Firmware Storage Internal CompactFlash
Operating System Storage Internal CompactFlash

Module Series

Series Module Designation
Series A 2711P-RP1x/A
Series B 2711P-RP1x/B
Series C 2711P-RP1x/C
Series D 2711P-RP1x/D
Series E 2711P-RP1x/E
Series F 2711P-RP1xx/F
Series G 2711P-RP1xxx/G

Connections/Interfaces

Interface Function
Ethernet Port Ethernet network connection
Serial Port Serial communication connection
USB Ports Two USB device connections
CompactFlash Card Slot External CompactFlash card access
Internal CompactFlash Interface Firmware and operating-system storage
Display Module Connectors Connection between the logic module and display module
Status Indicators Module operating-status indication

Installation Guidelines

  • Disconnect all power from the terminal before installing or replacing the module.
  • Disconnect all power and communication cables before module removal.
  • Wear a properly grounded ESD wristband.
  • Work in a static-free environment.
  • Avoid touching exposed electronic components.
  • Install the RAM and internal CompactFlash before attaching the logic module when supplied separately.
  • Place the display module face-down on a clean, flat, stable surface.
  • Align the two logic-module connectors with the display-module connectors.
  • Press the logic module down until it is firmly seated.
  • Tighten the six captive screws to 0.58 N m (5 to 7 lb in).
  • Remove any attached communication module before replacing the logic module.
  • Reinstall the communication module after the logic module is securely mounted.
  • Verify the logic-module series before transferring RAM or internal CompactFlash components.
Loading product navigation…

Which terminals support the module?

The module family is designed for PanelView Plus 700 to 1500 terminals.

How much memory does the module include?

The module family includes 64 MB internal CompactFlash and 64 MB RAM.

Which communication interfaces are provided?

The module includes one Ethernet port, one serial port, and two USB ports.

Can the internal memory be replaced?

Yes. The RAM and internal CompactFlash can be installed or replaced separately.

What mounting torque is required?

Tighten the six captive screws to 0.58 N m, equivalent to 5 to 7 lb in.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails sehen Sie bitte unsere offiziellen Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz
Country of origin
Vereinigte Staaten
Power source
Gleichstromversorgung

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere fortgeschrittene Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Backen hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...