Engineered for high-performance automation tasks requiring compact DIN-rail mounting, the Beckhoff CX5140-N031-0004 represents an industrial-grade controller equipped with an Intel Atom quad-core processor. This unit integrates a dedicated N031 RS422/RS485 serial option interface, allowing full-duplex communication endpoints directly from the processor assembly. Designed to operate without a fan, the device leverages passive cooling architecture to deliver robust execution of TwinCAT control tasks, making it ideal for high-speed PLC, motion control, and communication gateway applications.

Key Features

  • Intel Atom Quad-Core Processor: Delivers high-speed, multi-core computational power optimized for real-time automation sequences and deterministic control loops.
  • N031 Serial Interface: Standard 9-pin D-sub female socket configured for RS422/RS485 operation as a terminated full-duplex end point.
  • Dual Gigabit Ethernet Ports: Dual independent RJ45 interfaces supporting 10/100/1000 Mbps for separated network topologies and control communication.
  • Universal I/O Connectivity: Automatic detection and bus-switching support for either EtherCAT Terminals (E-bus) or standard Bus Terminals (K-bus).
  • Robust Maintenance-Free Design: Fanless operations with solid-state storage media compatibility, minimizing mechanical failure risks in harsh environments.

Industrial Applications

  • High-Speed Packaging Machinery: Serves as the primary motion control platform coordinating multi-axis synchronized drives via EtherCAT.
  • Process Control Gateways: Bridges legacy field networks utilizing the RS422 serial interface to modern EtherCAT or TCP/IP enterprise layers.
  • Wind Energy & Power Generation: Performs deterministic turbine control and structural monitoring under broad temperature variances.
  • Distributed Building Automation: Coordinates lighting, HVAC, and subsystem integration across expansive physical facilities.

Technical Specifications

Specification Parameter Value / Description
Manufacturer Beckhoff
Model Number CX5140-N031-0004
Processor Intel Atom (1.91 GHz, Quad-Core)
Memory Config 4 GB DDR3 RAM (Internal, non-expandable)
Serial Interface (N031) RS422 / RS485 (9-pin D-sub, female)
Ethernet Interfaces 2 x RJ45 (10/100/1000 Mbit/s, independent)
USB Ports 4 x USB 2.0
Display Interface 1 x DVI-D
Bus System Connection E-bus (EtherCAT) or K-bus (standard terminal bus) automatic detection
Operating Voltage 24 V DC (-15% / +20%)
Operating Temperature -25 degC to +60 degC
Shipping Weight (Calculated) 3.00 kg

Connections and Interfaces

The N031 option provides a serial interface configured for full-duplex RS422 end point operation with internal termination resistors engaged. The connection is made via a 9-pin D-sub female connector with the following pin assignments:

D-sub Pin Signal Assignment (RS422 Full Duplex)
Pin 2 TxD+ (Transmit Data +)
Pin 3 RxD+ (Receive Data +)
Pin 5 GND (Signal Ground)
Pin 7 TxD- (Transmit Data -)
Pin 8 RxD- (Receive Data -)

Empirical Engineering Insights

Alternative Models & Compatibility

The CX5140-N031-0004 can direct-replace standard CX5140-0004 systems, provided that any system-level application profiles are updated in TwinCAT System Manager to map the virtual COM port allocated to the N031 serial chip. Note that changing physical terminal bus attachments from standard K-bus to E-bus does not require manual hardware switching, as the internal controller automatically queries and initiates the correct physical layer driver upon boot.

Application Pitfalls & Engineering Notes

Because the N031 interface features non-switchable internal terminating resistors, adding external termination blocks at the controller end of the RS422 bus segment will result in excessive signal loading. Double-termination at the local node can degrade communication signal margins, resulting in sporadic CRC or framing errors, particularly when operating at high baud rates over long distances.

Commissioning & Wiring Tips

When routing serial links beside high-voltage motor cables, verify that the 9-pin D-sub metallic hood makes robust, continuous 360-degree connection to the cable shield. Ensure that shield ground is connected only at a single ground bus reference inside the primary enclosure to block ground loop currents from traversing the communication lines.

Installation Guidelines

CRITICAL WARNING

Isolate and completely shut down all primary and auxiliary 24 V DC power sources before mounting or dismounting the CPU block. Attempting to couple or uncouple bus terminals (E-bus/K-bus) with power applied will generate transient voltage spikes that can permanently ruin the electronic backplane logic.

1
Mount the device onto a standard 35 mm DIN rail (EN 60715) by pressing the integrated locking tab downwards, positioning the unit against the rail, and letting the tab latch back into position securely.
2
Align adjacent E-bus/K-bus terminals to the right-hand interface, pushing them together until the physical interlocking lock latches click.
3
Establish the power system and serial connections using insulated 24 V DC power cables with a nominal wire cross-section of at least 1.0 mm² to limit transmission drop voltage under high CPU loads.
Loading product navigation…

What is the function of the N031 option code on this Embedded PC?

The N031 option designates an integrated serial port configured as an RS422/RS485 interface via a 9-pin D-sub socket. It operates as a full-duplex end point with internal termination enabled.

Which software environments are compatible with this CX5140 module?

This hardware revision is optimized for the TwinCAT 3 runtime environment under Windows Embedded Compact 7, enabling real-time control, PLC, and motion control configurations.

How does the unit handle I/O terminal connections?

The controller features a direct backplane interface that automatically detects and communicates with either EtherCAT Terminals (E-bus) or Bus Terminals (K-bus).

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...