1 von 1

Beckhoff EL5021-0090 EtherCAT Terminal 1-Channel SinCos Encoder Interface

Beckhoff EL5021-0090 EtherCAT Terminal 1-Channel SinCos Encoder Interface

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: BECKHOFF

  • Produkt-Nr.: EL5021-0090

  • Herkunftsland:Deutschland

  • Produkttyp: EtherCAT Terminals

  • Zahlung: T/T, Western Union

  • Gewicht: 2000g

  • Abmessungen: 12 mm x 100 mm x 68 mm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Processing precise differential 1 VPP signals for high-performance motion feedback, the Beckhoff EL5021-0090 EtherCAT Terminal incorporates integrated TwinSAFE SC (Single Channel) technology to enable safety-related data transmission in standard control environments. This terminal interfaces seamlessly with high-resolution SinCos encoders, utilizing a 70 MHz internal scanning system to process input frequencies up to 250 kHz with a max resolution of 13 bits per period. Built-in error detection flags signal degradation, amplitude faults, and frequency boundaries, allowing for real-time diagnostic visibility directly within the TwinCAT architecture.

Features

  • TwinSAFE SC Support: Allows the use of standard analog signal sources for safety-directed tasks up to PL d/Category 3 or SIL 2.
  • High-Resolution Tracking: Max 13-bit resolution providing up to 8192 steps per signal period.
  • Advanced Diagnostics: Built-in hardware detection for amplitude and frequency errors, latch, and counter reset functions.
  • Synchronized Execution: Distributed Clocks (DC) support ensures highly precise microsecond-level synchronization across the EtherCAT network.
  • Integrated Signal Conditioning: Generates a stable 5 V DC encoder supply (up to 0.5 A) directly from the 24 V DC power contacts.

Applications

  • High-speed servo axis position feedback in multi-axis machinery.
  • Safety-related speed and direction monitoring (TwinSAFE SC architectures).
  • Precision positioning systems on CNC lathes, milling machines, and gantries.
  • Dynamic material testing equipment requiring microsecond feedback loops.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation
Model / Article Number EL5021-0090
Technology SinCos encoder interface for differential 1 VPP signal
Number of Channels 1
Encoder Interface Inputs 1 x A, B, C: differential inputs 1 VPP: A, A (inv), B, B (inv), C, C (inv)
Encoder Operating Voltage 5 V DC / max. 0.5 A (derived from 24 V DC power contacts)
Counter Range Max. 24 bit (adjustable)
Input Frequency 250 kHz (internal scanning of input signals at 70 MHz)
Nominal System Voltage 24 V DC (-15% / +20%)
Resolution Max. 13 bit, 8192 steps per period
Current Consumption (E-Bus) Typically 120 mA
Current Consumption (Power Contacts) Typically 50 mA + encoder load
Distributed Clocks (DC) Yes, supported
Electrical Isolation 500 V (E-bus / field potential)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals & Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Connection Cross-Section (AWG) Solid/Stranded: AWG 28...14; Ferrule: AWG 26...16
Net Weight Approximately 55 g
Shipping Weight (Calculated) 2.0 kg (with protective export packaging)
Country of Origin Germany

Connections and Interfaces

Terminal Point Signal Name Function / Description
1 A + Positive differential input channel A (1 VPP)
2 B + Positive differential input channel B (1 VPP)
3 C + Positive differential input channel C / Zero pulse (1 VPP)
4 +5 V Out Encoder power supply output (+5 V DC, max. 0.5 A)
5 A - Negative differential input channel A (1 VPP)
6 B - Negative differential input channel B (1 VPP)
7 C - Negative differential input channel C / Zero pulse (1 VPP)
8 0 V Out Encoder power supply ground (0 V DC)

Empirical Engineering Insights

Alternative Models & Compatibility

The EL5021-0090 acts as the safety-enhanced alternative to the standard EL5021-0000. While they share identical physical dimensions and signal wiring assignments, the -0090 contains TwinSAFE SC logic. Integrating the EL5021-0090 into an existing system requires mapping the safety process data objects (PDOs) inside TwinCAT 3 (using the TwinSAFE SC helper protocol). If a direct drop-in replacement is performed on a system where standard TwinSAFE SC parameters are not declared in the project, the PLC will fail to initialize the EtherCAT state machine beyond Pre-OP due to XML device description mismatches.

Application Pitfalls & Engineering Notes

E-Bus Current Allocation: The EL5021-0090 has a high E-bus current draw of 120 mA. When grouping multiple high-speed encoder interfaces on a single EK1100 coupler, you must calculate the total E-bus current. If the cumulative load exceeds 2 A, a secondary power feed terminal (such as EL9410) must be added immediately before the encoder modules to prevent voltage drops on the E-bus and subsequent bus interruption faults.

Signal Attenuation: 1 VPP differential signals are highly susceptible to noise over long distances. High-frequency operations (>150 kHz) require low-capacitance, double-shielded twisted-pair cabling. Keep distances between the encoder and the terminal under 20 meters; longer lengths risk triggering "Amplitude Error" diagnostics in the TwinCAT status word.

Commissioning & Wiring Tips

To bypass noise-induced commissioning errors, verify that the encoder cable shield is terminated to an earth-ground bar immediately before entering the terminal block. Avoid running the 1 VPP encoder cables parallel to high-power motor power cables inside the wire ducting. When commissioning in TwinCAT, activate the diagnostic PDOs to monitor the Amplitude Error and Frequency Error flags. This allows on-site technicians to diagnose mechanical encoder misalignments or bad cable terminations before putting the axis into operation.

Installation Guidelines

CRITICAL WARNING

De-energize all 24 V DC power contacts and the main E-bus supply before installing, removing, or wiring the terminal. Inserting or removing the EL5021-0090 under load can damage the internal E-bus transceiver chips and corrupt the TwinSAFE SC safety validation state in the safety group.

1
DIN Rail Mounting: Position the terminal on a standard 35 mm DIN rail (conforming to EN 60715) and push down firmly until the locking slide clicks onto the rail. Ensure the side-by-side key and slot connection fits snugly with neighboring terminals.
2
Shield Connection: Run the encoder shield directly to an adjacent EL9195 or standard shield clamp terminal connected to the DIN rail to guarantee low-impedance high-frequency noise diversion.
3
Wiring the Spring Clamps: Insert a standard flathead screwdriver into the upper square release slot of the clamp, insert the stripped wire (stripping length 8 to 9 mm) into the circular feed, and release the screwdriver to lock.
Loading product navigation…

What is the key difference between the EL5021-0000 and the EL5021-0090?

The EL5021-0090 features TwinSAFE SC (Single Channel) technology. This enables safety-related processing of standard analog 1 VPP encoder inputs in a TwinSAFE safety system up to PL d/Category 3 or SIL 2.

What is the maximum frequency and scanning rate of the EL5021-0090?

The terminal supports a maximum differential input frequency of 250 kHz. The internal scanning hardware samples the incoming analog sinusoidal signals at 70 MHz.

How is the 5 V DC encoder supply generated and what is the limit?

The 5 V DC supply is generated internally from the 24 V DC power contacts. It can deliver a maximum current of 0.5 A to power the connected SinCos encoder.

What does a TwinCAT 'Amplitude Error' flag mean on this module?

An Amplitude Error indicates that the differential voltage of the SinCos signal has dropped below the minimum operating threshold (typically below 0.6 VPP). This is commonly caused by extreme cable lengths, poor shield grounding, or physical wear on the encoder head.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Deutschland

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...