  • Manufacturer: General Electric

  • Product No.: PQMII-T20-C-A

  • Country of origin:Kanada

  • Product Type: Power Quality Monitor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 40g

  • Dimensions: 5 cm x 1,3 cm x 4,4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Anzahl
Vollständige Details anzeigen

Description

The GE Multilin PQMII-T20-C-A is an industrial power quality monitoring device designed to perform continuous metering, electrical parameter analysis, and control functions within electrical substations and facility power networks. This fully optioned assembly integrates a baseline measurement module with a localized alphanumeric display panel to log all fundamental current, voltage, and power vectors. Equipped with the T20 transducer option, the module provides four isolated analog outputs and a 4-20 mA analog input alongside a secondary RS485 communication link. The C control configuration expands system utility by adding three programmable output relays and four hardware switch inputs, while the A power analysis suite implements harmonic evaluation, waveform capture, and dedicated voltage disturbance tracking directly inside the localized memory registers.

Features

  • Comprehensive Power Metering: Tracks three-phase voltage and current waveforms alongside active, reactive, apparent power, and power factor vectors.
  • Isolated Transducer Interface: Incorporates 4 isolated analog outputs (0-20 mA or 4-20 mA) assignable to any measured parameter and 1 specialized 4-20 mA analog input channel.
  • Programmable Relay Control: Features 4 programmable output relays and 4 discrete contact switch inputs to coordinate localized interlocking or alarm routing.
  • Power Quality Diagnostics: Provides advanced harmonic profiling, triggered trace memory capture, an internal event recorder, and data logging functions.
  • Redundant Data Networking: Outfitted with 2 independent serial RS485 communication interfaces and 1 dedicated front-access RS232 port.

Applications

  • Utility and commercial power substation tracking.
  • Motor control center and distribution switchgear loading monitoring.
  • Harmonic distortion profiling and power factor correction supervision.
  • Feeder diagnostic capture and voltage disturbance logging.

Ordering Information

Base Model / Suffix Functional Description
PQMII Basic unit with display, all current/voltage/power measurements, one (1) RS485 port, one (1) RS232 port
T20 Four (4) isolated analog outputs (0-20 mA / 4-20 mA), 4-20 mA analog input, second (2nd) RS485 port
C Three (3) additional programmable output relays (total of 4), 4 programmable switch inputs
A Harmonic analysis, triggered trace memory, waveform capture, event recorder, data logger, voltage disturbance recorder

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Manufacturing Location Ontario, Canada
Product Type Power Quality Meter
Processor Frequency 25 MHz
Analog Outputs (T20) Four (4) isolated channels, 0-20 mA or 4-20 mA assignable
Analog Inputs (T20) One (1) channel, 4-20 mA configuration
Discrete Intf (C) 4 programmable switch inputs / 4 total programmable output relays
Analysis Package (A) Harmonic tracking, trace memory, event log, voltage disturbance recorder
Serial Interfacing Two (2) RS485 ports, One (1) RS232 port
Operating Temperature -20 degC to +70 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 5% to 95% non-condensing

Installation Guidelines

Panel Cutout and Mounting

Prepare a standard rectangular vertical panel opening matching the housing dimensions defined in the installation layout. Insert the meter from the front face of the dashboard frame and tighten the rear-accessed integrated clamp bolts evenly to seal the front bezel gasket against dust or moisture entry.

Instrument Transformer Connections

Route all secondary voltage transformer (VT) and current transformer (CT) wires through localized external shorting or isolation switches. Ensure that no active current transformer secondary path becomes open-circuited while primary grid load is actively present.

Terminal Grounding

Connect a dedicated, low-impedance safety ground wire from the rear chassis grounding stud directly to the main copper station panel bus. Clean all contact surfaces of protective coatings or oxidation prior to fastening the grounding lug.

Serial Link Termination

When implementing long RS485 communication runs, install a matching 120-ohm termination resistor across the differential signal lines at the final terminal point of the network segment to suppress signal reflection and prevent telemetry corruption.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin PQMII-T20-C-A Power Quality Meter

正在加载 PDF,请稍候…

Welche Parameter können den vier isolierten Analogausgängen der T20-Option zugewiesen werden?

Die vier isolierten Analogausgänge können so zugewiesen werden, dass sie jeden der gemessenen Strom-, Spannungs-, Frequenz-, Leistungsfaktor- oder berechneten Leistungsparameter abbilden.

Wird die Funktion des Spannungsstörungsrekorders in dieser spezifischen Konfiguration vollständig unterstützt?

Ja, der Spannungsstörungsrekorder wird bei diesem Modell unterstützt, da die vollständige PQMII-T20-C-A-Konfiguration den erforderlichen 25-MHz-Hardwareverarbeitungskern enthält.

Wie viele programmierbare serielle Schnittstellen sind insgesamt an der PQMII-T20-C-A-Einheit verfügbar?

Das Gerät verfügt insgesamt über drei serielle Schnittstellen: zwei unabhängige RS485-Anschlüsse an den hinteren Klemmenblöcken und einen RS232-Anschluss an der Frontplatte.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Schwarz Blau
Country of origin
Kanada

Recently Viewed Products

Technical knowledge

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...

Programmierung von Ein-Achsen-Bewegungszyklen auf einem CMZ-Servoantrieb

Dieses Tutorial untersucht, wie die integrierte SPS-Funktionalität in einem CMZ SBD-Servoantrieb eigenständige Bewegungsprogramme ausführen kann, einschließlich Referenzfahrt-Logik,...

Einachsige Bewegungssteuerung mit CMZ-Servoantrieben einrichten

Dieses Tutorial behandelt die Inbetriebnahme eines einachsigen Servobewegungssystems mit einem CMZ SBD-Antrieb und umfasst die Hardwareeinrichtung, Achsenskalierung, Homing-Konfiguration und die...