1 von 1

Honeywell LCNP4E 51405098-100 LCN PCI Express Module

Honeywell LCNP4E 51405098-100 LCN PCI Express Module

Nur noch 4 Artikel auf Lager verfügbar
  • Hersteller: Honeywell

  • Produkt-Nr.: LCNP4E / 51405098-100

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: LCN Interface Cards

  • Zahlung: T/T, Western Union

  • Gewicht: 2000g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

The Honeywell 51405098-100 (commonly designated as the LCNP4E) is a specialized Local Control Network interface board engineered for integration within legacy Honeywell TDC 3000 and Honeywell Experion PKS distributed control systems (DCS). Functioning as a high-performance coprocessor card, this module installs into a standard PCI Express (PCIe) slot of a host workstation or server. It provides the essential physical and protocol link required for the host operating system to communicate deterministically with the Honeywell coaxial Local Control Network (LCN).

By offloading low-level network protocol stacks and critical transmission timing from the host computer's primary CPU, the LCNP4E Card Module ensures highly reliable, real-time data exchange for operator interfaces, alarm management, historical data archiving, and engineering configuration tools. Its hardware design is specifically optimized to maintain stable throughput under high-density industrial communication demands.

Features

  • PCI Express Interface: Utilizes standard PCIe bus connectivity for broad compatibility with modern industrial PCs and server motherboards.
  • On-Board Coprocessor: Dedicates localized hardware resources to handle LCN communication protocols, minimizing host CPU overhead.
  • Dual-Redundant Ports: Equipped with dual coaxial connections to seamlessly interface with redundant (A and B) Local Control Network physical topologies.
  • Diagnostic Indicators: Features onboard LED status lights for rapid troubleshooting of link activity, board health, and communication faults.
  • System Compatibility: Engineered for direct integration with Honeywell Experion and classic TDC 3000 system architectures.

Applications

  • Honeywell TDC 3000 Operator Station upgrades.
  • Experion PKS LCN connection node interfaces.
  • Process control network legacy-to-modern PC migrations.
  • Power generation, chemical processing, and oil refining DCS environments.

Technical Specifications

Manufacturer Honeywell
Part Number / Model LCNP4E / 51405098-100
Interface Slot Type PCI Express (PCIe)
Network Compatibility Honeywell Local Control Network (LCN)
Physical Connector Type Dual Coaxial BNC Connections
Shipping Weight 2.0 kg

Connections and Interfaces

Connector / Indicator Function Description
LCN Port A Connection point for the primary LCN coaxial network segment.
LCN Port B Connection point for the redundant LCN coaxial network segment.
LED Status Indicators Real-time visual feedback for communication transmit/receive and hardware status.

Installation Guidelines

  • Static Protection: Use a grounded ESD wrist strap and anti-static mat when handling the card to prevent damage to sensitive CMOS components.
  • Power Sequencing: Always shut down the host industrial PC and disconnect the main AC power supply before inserting or removing the module.
  • Slot Alignment: Align the module card-edge carefully with the targeted PCIe slot and apply even downward pressure until fully seated. Secure the mounting bracket screw to the chassis frame.
  • Cable Integrity: Use properly specified coaxial cables and BNC terminators to connect to the LCN network to avoid signal reflection and communication packet losses.
Loading product navigation…

What is the function of the Honeywell LCNP4E card module?

The LCNP4E (51405098-100) is a PCI Express co-processor card that interfaces a standard host PC or workstation with the legacy Honeywell Local Control Network (LCN) in TDC 3000 and Experion systems.

Does the 51405098-100 module support redundant network cables?

Yes, it is equipped with dual coaxial BNC connectors to interface with redundant LCN cable segments (A and B) for high availability.

Which system environments are compatible with this card?

It is designed for use in PC-based systems connected to Honeywell TDC 3000 systems and Experion PKS DCS environments that require physical LCN access.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...