1 von 1

Mitsubishi Electric FR-E840-0120-4-60 FR-E800 Series Variable Frequency Drive

Mitsubishi Electric FR-E840-0120-4-60 FR-E800 Series Variable Frequency Drive

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: Mitsubishi Electric

  • Produkt-Nr.: FR-E840-0120-4-60

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Variable Frequency Drives

  • Zahlung: T/T, Western Union

  • Gewicht: 2400g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Engineered for precise speed and torque control in three-phase industrial environments, the Mitsubishi Electric FR-E840-0120-4-60 serves as a highly reliable 400V class variable frequency drive within the FR-E800 series portfolio. This compact inverter is rated for a Normal Duty (ND) current of 12.0 A, delivering robust performance under heavy cyclic loads. Designed to thrive in demanding automation settings, this unit includes standard conformally coated circuit boards to guard against atmospheric contaminants and moisture, making it an excellent match for material handling, HVAC, and pumping operations. Utilizing Source logic for its control and safety stop inputs, it integrates smoothly into standard safety-instrumented systems requiring high uptime and predictable safety response.

Key Features

  • Conformal Circuit Board Coating: Enhanced environmental protection (-60 designation) prevents corrosion and tracking faults from dust and humidity.
  • Source Logic System: Built-in Source logic for standard digital inputs and fixed Source logic for integrated safety stop signals.
  • AM Terminal Voltage Monitoring: Outfitted with an analog voltage monitoring output (Terminal AM) for real-time operation tracking.
  • Advanced Thermal Management: Compact design with built-in cooling fan optimized for tight control panel spacing.
  • Integrated Safety Stop: Supports functional safety requirements with dedicated dual-channel safety inputs to isolate motor power safely.

Industrial Applications

  • Conveyor and Logistics Systems: Smooth acceleration and deceleration control for heavy-load conveyor lines.
  • Pumping and Fan Systems: Energy-efficient variable flow and pressure regulation using built-in PID control loops.
  • Packaging Machinery: High-response speed profiles matching operational packaging sequences.
  • Textile and Material Processing: Constant tension and winding controls utilizing precise analog monitoring feedback.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-E840-0120-4-60
Series Name FR-E800 (FR-E8)
Voltage Class 400 V Class (Three-Phase Input)
Inverter ND Rated Current 12.0 A
Rated Frequency (Initial Setting) 50 Hz
Input Signal (Initial Status) Source logic
Safety Stop Signal Logic Source logic (Fixed)
Monitoring Interface Voltage (Terminal AM)
Circuit Board Coating Conformally coated boards (with coating)
Plated Conductor Without plated conductors
Cooling Type Forced Air Cooling
Net Weight 2.4 kg
Shipping Weight (Calculated) 5.0 kg

Connections and Interfaces

Terminal Symbol Terminal Name Description / Signal Allocation
R/L1, S/L2, T/L3 Main Circuit Power Input Connects to the three-phase AC power supply (380 to 480 V AC, 50 Hz / 60 Hz).
U, V, W Inverter Output Terminals Connects to the three-phase induction or permanent magnet motor.
AM Analog Monitor Output Provides analog voltage output (0 to 10 VDC) for monitoring parameter values.
PC External Transistor Common Acts as the 24 VDC common power supply source for digital inputs (Source logic configuration).
S1, S2, SIC Safety Input Terminals Used for functional safety shutdown loops (STO) in compliance with SIL2/SIL3 standards.

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems from the older FR-E740-120-EC or FR-E740-120-NA, the newer FR-E840-0120-4-60 offers matching physical mounting dimensions but incorporates advanced safety logic and enhanced parameter groups. Be sure to backup your original parameters via FR Configurator2 software. When downloading to the FR-E840, some advanced motor constants may need manual conversion if operating older non-standard permanent magnet motors.

Application Pitfalls & Engineering Notes

Operating this inverter inside tightly enclosed, sealed panels can result in localized thermal build-ups. Ensure that surrounding clearance parameters (minimum 50 mm above and below, 20 mm on the sides) are strictly maintained to permit effective convection. When wiring safety inputs (S1 and S2), note that the safety stop terminal logic is fixed to Source logic. Attempting to use a 0V common path to control safety circuits on this specific model variant will cause hard safety interlock faults (e.g., SA status fault indication).

Commissioning & Wiring Tips

To minimize high-frequency electromagnetic interference (EMI) on the analog AM monitoring terminal, always utilize a separate shielded twisted pair (STP) cable for control signals. Ground the shield at the inverter side only, specifically to the dedicated control ground terminal. If the motor cables exceed 30 meters in length, install an output dV/dt filter or reduce the carrier frequency (Pr. 72) to prevent excessive leakage currents and premature insulation aging in the motor windings.

Installation Guidelines

CRITICAL ELECTRICAL SAFETY WARNING Ensure the input main power line (R/L1, S/L2, T/L3) is completely de-energized and locked out before initiating any wiring or terminal access. The intermediate DC link capacitors retain dangerous electrical potential after power-off. Wait a minimum of 10 minutes following complete power disconnection, and verify that the charge indicator LED on the face of the unit is completely off before servicing terminal connections.
1 Securely mount the inverter vertically on a flat, vibration-free surface. Ensure that airflow to the heatsink fins is not obstructed by conduit runs or wire trays.
2 Route the main power lines separately from the low-voltage control lines (safety, analog output, and logic circuits) to prevent signal coupling and electromagnetic cross-talk.
3 Ensure the grounding terminal (PE) is bonded to the main system ground bus via a heavy-gauge, low-impedance conductor (minimum cross-section equivalent to power conductors).
4 Perform a continuity check on all output phases (U, V, W) to confirm that no phase-to-phase or phase-to-ground short circuits exist before powering up the drive.

What does the -60 suffix indicate on this specific drive?

The -60 suffix specifies that the control circuit boards have a conformal coating for enhanced environmental protection against humidity and conductive dust, but without nickel/tin-plated copper conductors.

What is the rated current for this model in Normal Duty?

The rated output current is 12.0 Amps under Normal Duty (ND) conditions at 400V class three-phase input.

Can the control logic be configured for Sink logic instead of Source logic?

No, the safety stop signal logic is fixed to Source logic for this specific model configuration (-4 variant).

What parameter controls the initial frequency setting on this unit?

The initial base frequency setting is pre-programmed to 50 Hz, but can be modified via Parameter 3 (Base Frequency) to match 60 Hz networks during initial setup.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...