Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 125712-01

  • Country of origin:Egyesült Államok

  • Product Type: Relay Modules

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 241 mm x 24.4 mm x 99.1 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The 125712-01 is a full-height spare component designed to provide four independent relay outputs within the 3500 Series Machinery Protection System. This module functions by executing highly customizable voting logic directly driven by machine alerts and danger levels across the system enclosure. Each output terminal incorporates specialized Alarm Drive Logic, which can be custom configured with complex AND or OR Boolean expressions using the 3500 Rack Configuration Software to manage specific automated trip signals. It operates reliably when located to the right of the main Rack Interface Module, delivering discrete contact outputs for field control links, emergency stop systems, or external industrial annunciators.

Features

  • Four fully programmable, independent relay outputs supporting complex localized system voting logic.
  • Configurable Alarm Drive Logic utilizing combinational AND/OR gate selections for flexible machine-state actions.
  • Multi-channel compatibility accepting alert and danger alarm inputs from any active monitor card in the local rack.
  • Front-panel visual diagnostics including dedicated LEDs for Module OK, active TX/RX communications, and individual relay state indicators.
  • High-integrity epoxy-sealed relay hardware utilizing pairs of single-pole double-throw (SPDT) relays in a unified double-pole double-throw (DPDT) physical arrangement.
  • Hardware switch-selectable functionality for setting channels to either Normally Energized (NE) or Normally De-energized (NDE) operation.

Applications

  • Mechanical trip systems and emergency shutdown integration.
  • Automated industrial voting logic and alarming systems for large rotating assets.
  • Critical turbomachinery and industrial compressor protective interlocking networks.

Ordering Information

Part Number / Option Description
3500/32-A01-B00 4-Channel Relay Module with I/O Module, No Agency Approvals 
3500/32-A01-B01 4-Channel Relay Module with I/O Module, CSA/NRTL/C Approval 
125712-01 Spare 4-Channel Relay Module (Main Board) 
125720-01 Spare 4-Channel Relay I/O Module 
00580436 Connector Header, Internal Termination, 6-position, Green 

Technical Specifications

Category Specification Data
Electrical Power Consumption 6 watts typical 
  Relay Type Two SPDT relays connected in a DPDT configuration 
  Environmental Sealing Epoxy-sealed 
  Arc Suppressor 250 Vrms, installed as standard 
Contact Ratings Max Switched Current 5 A 
  Max Switched Voltage (dc) 30 Vdc 
  Max Switched Voltage (ac) 250 Vac 
  Max Switched Power (dc) 120 W 
  Max Switched Power (ac) 600 VA 
  Minimum Switched Current 10 mA @ 5 Vdc 
  Contact Life 100,000 cycles @ 5 A, 24 Vdc or 120 Vac 
Environmental Operating Temperature -30 degC to +65 degC (-22 °F to +150 °F) 
  Storage Temperature -40 degC to +85 degC (-40 °F to +185 °F) 
  Humidity 95%, non-condensing 
Mechanical Main Module Dimensions (H x W x D) 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) 
  Main Module Weight 0.7 kg (1.6 lb.) 
  Rack Space (Main Module) 1 full-height front slot 
  Rack Space (I/O Module) 1 full-height rear slot 
  Manufacturer Bently Nevada 

Connections/Interfaces

Terminal Designation Function
NC Normally Closed contact connection terminal for external equipment loops 
ARM Armature (Common) contact interface terminal for external field wiring 
NO Normally Open contact connection terminal for external equipment loops 
RELAY MODE (Switch) Hardware selector switches for Normally De-energized (NDE) or Normally Energized (NE) mode 

Installation Guidelines

  • Slot Allocation: Position the module in any available full-height slot directly to the right of the 3500 Rack Interface Module.
  • Relay Mode Configuration: Before commissioning, configure individual channel hardware switches located on the module to specify either Normally De-energized (NDE) or Normally Energized (NE) operation based on the field device type.
  • Software Configuration: Use the 3500 Rack Configuration Software to map specific combinations of alert or danger alarms across monitor channels into the module's localized Alarm Drive Logic.

Compliance and Certifications

  • EMC Emissions: EN 55011 Class A (Radiated and Conducted Emissions).
  • EMC Immunity: IEC61000-6-2, EN 61000-4-2 (Electrostatic Discharge Criteria B), ENV 50140 (Radiated Susceptibility Criteria A), ENV 50141 (Conducted Susceptibility Criteria A), EN 61000-4-4 (Electrical Fast Transient Criteria B), EN 61000-4-5 (Surge Capability Criteria B), 61000-4-8 (Magnetic Field Criteria A), EN 61000-4-11 (Voltage Dip Criteria B), ENV 50204 (Radio Telephone Criteria B).
  • Safety Requirements: EN 61010-1 Low Voltage Directives.
  • Hazardous Area Approvals: CSA/NRTL/C; Class I, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 condition. Certification Number: CSA 150268-1002151 (LR 26744).

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 125712-01 4-Channel Relay Module

Can this relay module be used in Triple Modular Redundant configurations?

No. Triple Modular Redundant (TMR) applications require the use of the 3500/34 TMR Relay Module instead of this standard 4-channel version.

What are the contact ratings for resistive loads on these relays?

The maximum ratings are 5 A with a maximum switched voltage of 30 Vdc or 250 Vac. The maximum switched power is 120 W for DC or 600 VA for AC.

How do you program the voting and driving logic for each channel?

The voting logic is configured by setting up AND and OR gates using the 3500 Rack Configuration Software, which pulls alert and danger states from monitor channels.

What do the front-panel TX/RX LEDs indicate?

The TX/RX LED flashes to indicate active and proper communications between this relay module and other modules within the 3500 rack framework.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Ezüst
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...