1 / 3

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

Only 4 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330730-040-01-00

  • Country of origin:Egyesült Államok

  • Product Type: 3300 XL 11 mm Extension Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Option 040 (4.0 m length) and Option 01 (armored coaxial cable) specify this 3300 XL 11 mm extension cable configuration — 330730-040-01-00. This 3300 XL 11 mm Extension Cable is used to bridge the physical gap between a 3300 XL 11 mm proximity probe and a 3300 XL 11 mm Proximitor sensor. It supports non-contact eddy-current displacement measurements in machinery protection systems.

Unlike non-armored standard cables (Option 02) or FluidLoc variants (Option 10), this variant is wrapped in a flexible AISI 302 stainless steel armor with an outer FEP jacket, protecting the internal coaxial line from physical abrasion and mechanical damage in demanding turbine or compressor environments. To maintain exact transducer system tuning, this 4.0 m cable must be paired with either a 1.0 m probe to form a 5.0 m system, or a 5.0 m probe to form a 9.0 m system. This Option 00 configuration is for applications that do not require specialized hazardous area approvals.

Features

  • Standard FEP insulated 75 ohm triaxial cable core with flexible AISI 302 SST protective armor.
  • FEP outer jacket over the armor to resist oil, water, and industrial chemical exposure.
  • Integrated gold-plated brass ClickLoc coaxial connectors (one male and one female) for stable signal transmission.
  • Cable length of 4.0 meters (13.1 feet), contributing to a calibrated 5.0 meter or 9.0 meter total system loop.
  • Minimum bend radius of 25.4 mm (1.0 in) simplifies installation and routing around machinery frames.

Applications

  • Steam and gas turbine rotor axial position monitoring.
  • Turbo-compressor shaft radial vibration measurement.
  • Critical rotating machinery protection within 11 mm transducer loops.
  • Mechanical monitoring installations requiring armored cable routing to prevent physical damage.

Ordering Information

Option Option Code on This SKU Description
Orderable Part Number 330730-040-01-00 3300 XL 11 mm Extension Cable
AAA - Cable Length Option 040 4.0 meters (13.1 feet)
BB - Connector and Cable Option 01 Armored cable (Flexible AISI 302 SST with FEP outer jacket)
CC - Agency Approval Option 00 Not required

Technical Specifications

Manufacturer Bently Nevada
Model / Part Number 330730-040-01-00
System Compatibility 3300 XL 11 mm Proximity Transducer System
Cable Construction 75 ohm triaxial coaxial cable, FEP insulated
Armor Protection Flexible AISI 302 SST armor with FEP outer jacket
Cable Length 4.0 m (13.1 ft)
Standard Cable O.D. 3.7 mm (0.15 in) maximum
Armored Cable O.D. 7.6 mm (0.30 in) maximum
Core DC Resistance (RCORE) 0.3 +/- 0.1 ohms
Shield/Jacket DC Resistance (RJACKET) 1.0 +/- 0.25 ohms
Extension Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Connector Material Gold-plated brass
Connector Types Miniature ClickLoc coaxial connectors (one male, one female)
Tensile Strength 270 N (60 lbs) maximum rated probe-to-cable tension
Minimum Bend Radius 25.4 mm (1.0 in)
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Relative Humidity Limit 100% condensing, non-submersible (with protected connectors)

Connections and Interfaces

Connector End Connector Type Function
Probe Connection End Miniature ClickLoc Female Coaxial Secures to the male connector of the 3300 XL 11 mm proximity probe
Sensor Connection End Miniature ClickLoc Male Coaxial Secures to the female connector of the 3300 XL 11 mm Proximitor sensor

Installation Guidelines

  • Cable Matching: The total combined length of the proximity probe lead and this extension cable must match the calibrated length (5.0 m or 9.0 m) of the paired Proximitor sensor.
  • Connector Connection: Ensure the ClickLoc connectors are clean, dry, and fully joined. Finger-tight connection is recommended, with a maximum connector-to-connector torque of 0.565 N-m (5 in-lb).
  • Protection: Apply silicone self-fusing tape or connector protectors to seal the connection from the environment. Silicone tape is not recommended if exposed directly to turbine oil.
  • Bend Radius: Avoid bending the armored cable tighter than the minimum 25.4 mm (1.0 in) radius during routing.
  • Mounting: Use appropriate cable clamps to support the armored cable along its run to prevent excessive strain on the connector ends.

Compliance and Certifications

  • EMC: EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)
  • RoHS: European Community Directive 2011/65/EU
  • FCC: Complies with Part 15 of the FCC Rules
  • Hazardous Areas: This Option 00 configuration is specified for environments where agency hazardous area approvals are not required.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

What does the 330730-040-01-00 configuration represent?

The part number represents a 3300 XL 11 mm extension cable with a length of 4.0 meters (Option 040), a flexible stainless steel armor sleeve with an outer FEP jacket (Option 01), and no specialized hazardous area approvals (Option 00).

Which proximity probes are compatible with this 4.0-meter extension cable?

This cable is designed for 3300 XL 11 mm systems. It must be paired with a 1.0-meter probe to complete a 5.0-meter system loop, or a 5.0-meter probe to complete a 9.0-meter system loop.

What is the minimum bend radius for this armored cable?

The minimum bend radius is 25.4 mm (1.0 inch) with or without the stainless steel armor sleeve.

What are the electrical resistance values of this 4.0-meter extension cable?

The cable has a typical coaxial shield-to-shield jacket resistance (RJACKET) of 1.0 +/- 0.25 ohms and a center conductor core resistance (RCORE) of 0.3 +/- 0.1 ohms.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...