1 / 3

Bently Nevada 991-25-50-02-00 991 Thrust Transmitter

Bently Nevada 991-25-50-02-00 991 Thrust Transmitter

Only 3 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 991-25-50-02-00

  • Country of origin:Egyesült Államok

  • Product Type: Thrust Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 430g

  • Dimensions: 100 mm x 74 mm x 53.3 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The 991-25-50-02-00 processed signal transmitter is designed to accept inputs from a proximity probe and sensor system to monitor micro-inch level axial shaft movement, specifically orients as a 991 Thrust Transmitter. This device functions as a self-contained, two-wire loop-powered transmitter that converts proximity probe measurements directly into a 4 to 20 mA current output proportional to the total thrust displacement. It integrates seamlessly with standard Programmable Logic Controllers (PLC), Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS), allowing operators to establish thrust monitoring without the requirement of a dedicated rack-based Machinery Protection System. The transmitter provides continuous machinery protection for rotating equipment including centrifugal compressors, steam turbines, pumps, and industrial fans.

Features

  • Integrates a non-contacting eddy current proximity probe sensor input into a standard 2-wire 4 to 20 mA loop interface.
  • Provides a buffered voltage output via a dedicated BNC connector for direct connection to portable vibration analyzers and diagnostic instrumentation.
  • Offers specialized circuitry for early detection of thrust bearing wear or potential catastrophic axial float failure.
  • Features a rugged, compact housing design compatible with high-density DIN rail mounting configurations.
  • Contains built-in circuit protection against reverse polarity and electrical surge anomalies.

Applications

  • Axial displacement and thrust position monitoring on high-speed centrifugal compressors.
  • Boiler feed pump thrust bearing wear tracking in power generation utilities.
  • Steam and gas turbine rotor axial position surveillance.
  • Industrial turbocharger and expander mechanical health monitoring.
  • Large electric motor and gear reducer shaft displacement tracking.

Ordering Information

Option Code Selection Type Description
991 Product Type Thrust Transmitter
25 Proximity Probe Option 3300 XL 8mm Proximity Probe
50 Scale Range Option 50-0-50 mils Range
02 Agency Approval Option Multiple Approvals (ATEX, IECEx, CSA)
00 Mounting Option Standard Mounting Option

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada
Model 991-25-50-02-00
Product Type 991 Thrust Transmitter
Origin United States
Input Type 3300 XL 8mm Proximity Probe and Extension Cable System
Output Type 4 to 20 mA DC (Linear proportional to thrust displacement)
Power Requirements 12 to 35 VDC at the transmitter terminals
Loop Resistance Maximum 1000 Ohms at 35 VDC supply voltage
Buffered Output Coaxial BNC connector, nominal output scale factor matching the proximity sensor
Accuracy Within specified linear range across standard operating temperatures
Operating Temperature -35 degC to +85 degC
Storage Temperature -40 degC to +100 degC
Mounting 35mm DIN rail or direct panel mount plate
Dimensions 81.3 mm x 61.2 mm x 103.4 mm
Weight 0.45 kg

Connections/Interfaces

Connector Pin Function
+4-20 mA Positive Loop Power / Current Output Connection
-4-20 mA Negative Loop Power / Current Output Return
PROBE Center Conductor for Proximity Probe Extension Cable Input
SHIELD Terminal Connection for Extension Cable Shield
COM Common Reference Point for Signal Testing
BNC Jack Dynamic Voltage Output (Raw Proximity Sensor Signal)

Installation Guidelines

  • DIN Rail Installation: Snap the housing onto standard 35mm symmetric top-hat DIN rails, ensuring both the top and bottom clips engage securely.
  • Grounding: Connect the transmitter housing directly to the local instrumentation clean ground or DIN rail ground block to avoid floating potentials.
  • Shielding: Terminate the outer shield of the field wiring cable at the control system end only; ensure the probe cable shield is connected directly to the designated transmitter shield terminal and isolated from the junction box.
  • EMI/RFI Mitigation: Route all low-level proximity sensor input cables in dedicated grounded metallic conduits separated from heavy AC power distribution wiring.
  • Probe Gap Adjustment: Ensure the proximity probe is gapped to the correct physical voltage range before securing the transmitter loop configuration to maximize dynamic linear performance.
  • Moisture Protection: Install the device within an IP65 or NEMA 4X rated enclosure when deploying into outdoor, high-humidity, or corrosive ambient environments.

Compliance and Certifications

  • CSA/NRTL/C
  • ATEX
  • IECEx

FAQ

What is the primary function of this transmitter?

It converts high-frequency proximity probe signals into a standard linear 4 to 20 mA loop-current signal representing shaft axial or thrust position.

Does this device require a separate power supply line?

No, it is a two-wire, loop-powered device that operates using the loop voltage provided by the receiving DCS or PLC analog input module.

How is a portable data collector connected to check raw vibration data?

A portable analyzer or oscilloscope can be connected directly to the front-panel BNC jack without disturbing the 4 to 20 mA automation control loop.

What specific proximity sensor system is compatible with the 25 option code?

The 25 option designates compatibility with the Bently Nevada 3300 XL 8mm proximity probe and extension cable system.

Can this unit be mounted directly inside a harsh outdoor environment?

It requires an appropriately rated protective enclosure to safeguard its electronic terminal blocks from moisture, dust, and corrosive airborne elements.

What is the impact of reversing the input loop polarity?

The unit features internal reverse polarity protection circuits that prevent electrical damage, though it will not transmit a valid signal until wired correctly.

Does this module require routine calibration in the field?

No, the device is factory-calibrated to specific linear ranges and does not require adjustment or manual potentiometer tuning during standard installation.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 991-25-50-02-00 991 Thrust Transmitter

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér Fekete
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...