1 / 3

Emerson KJ4001X1-NB1 12P3368X012 DeltaV Horizontal LocalBus Dual Left Cable

Emerson KJ4001X1-NB1 12P3368X012 DeltaV Horizontal LocalBus Dual Left Cable

Only 2 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: KJ4001X1-NB1 12P3368X012

  • Country of origin:Egyesült Államok

  • Product Type: Horizontal LocalBus Dual Left Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 16.6cm x 4.5cm x 6.2cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The Emerson KJ4001X1-NB1 (Part Number 12P3368X012) serves as the high-speed data lifeline within the DeltaV™ Distributed Control System. This Horizontal LocalBus Dual Left Cable facilitates the critical interconnection between redundant carrier segments, extending the system's backplane power and communication buses. Engineered for high-availability architectures, the "Dual" configuration ensures that both primary and standby data paths remain synchronized across separate hardware carriers. This specific "Left" orientation cable enables the expansion of I/O capacity while maintaining the millisecond-level determinism required for complex process control. By providing a low-impedance, shielded path for the LocalBus signals, the KJ4001X1-NB1 protects the system against data packet loss and electromagnetic interference in demanding industrial environments.


Technical Configuration

Dual-Path Redundancy

The cable assembly contains two independent sets of shielded conductors. This physical separation supports the DeltaV redundant architecture, allowing the "A" and "B" switches of the LocalBus to operate concurrently. If one physical path sustains damage, the system continues to function via the secondary path without triggering a processor reset.

LocalBus Extension Logic

The KJ4001X1-NB1 acts as a transparent extension of the carrier backplane. It carries the 12.5 VDC power for I/O modules along with the address and data lines. The "Horizontal" designation indicates its optimized length and flexibility for cabinets where carriers are mounted side-by-side rather than stacked vertically.

Shielding and Connector Integrity

The cable features heavy-duty industrial shielding and high-density pin connectors. The connector housings include integrated thumb screws to prevent accidental disconnection due to vibration or mechanical strain, ensuring a constant "Gas-Tight" electrical bond.


Technical Specifications

Feature Specification
Model Number KJ4001X1-NB1
Part Number 12P3368X012
System Compatibility Emerson DeltaV M-Series / S-Series
Cable Type LocalBus Redundant Extension
Orientation Horizontal / Dual Left
Connector Type High-Density Multi-Pin
Jacket Material Industrial Grade PVC / Flame Retardant
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Vibration Resistance IEC 60068-2-6 (1g, 10 to 150 Hz)
Compliance RoHS, CE

Installation & Maintenance Guide

Bend Radius and Routing

Technicians must respect the minimum bend radius of the cable (typically 10x the cable diameter). Avoid sharp 90-degree bends which can cause internal impedance mismatches or physical fatigue in the copper strands. Route the cable through dedicated wire ducts to keep it separate from high-voltage AC motor leads.

Connector Alignment

Before tightening the captive screws, ensure the connector is perfectly flush with the carrier port. Forced insertion can bend the high-density pins, leading to "LocalBus Fault" errors that are difficult to diagnose. Tighten the screws evenly to ensure uniform pressure across the pin matrix.

Continuity Testing

In the event of a communication error, perform a continuity check on both the primary and redundant paths. However, never perform a "Megger" or high-voltage insulation test on the cable while it is connected to the DeltaV carriers, as the test voltage will destroy the sensitive I/O electronics.


Engineering Advantages

The KJ4001X1-NB1 simplifies complex system expansions by providing a standardized, "Plug-and-Play" connection for extended I/O carriers. Its specialized "Dual Left" design is mission-critical for maintaining the spatial integrity of redundant systems, ensuring that the controller can address all field modules across the horizontal plane with zero latency penalties. The use of high-flex, oxygen-free copper ensures that the cable maintains its electrical characteristics over years of thermal cycling within a control cabinet. For engineers designing for harsh chemical or offshore environments, the cable's rugged jacket provides a high level of resistance to oil, moisture, and atmospheric contaminants.


Technical FAQs

Q1: What does the "Left" orientation refer to in the cable description?

A1: This refers to the physical port location on the carrier. "Dual Left" cables are designed to connect the left-hand ports of redundant carriers to the preceding segment in the bus chain, maintaining the correct logical sequence of the DeltaV nodes.

Q2: Can I use a KJ4001X1-NB1 to connect carriers vertically?

A2: While the electrical pinout is the same, this cable's length and molded strain relief are specifically optimized for horizontal mounting. Using it for vertical segments may cause excessive strain on the connectors; for vertical stacking, the "Vertical LocalBus" variants are recommended.

Q3: How does the system react if one half of the dual cable is disconnected?

A3: The DeltaV controller will generate a "LocalBus Redundancy Lost" alarm. The process will continue to run normally using the remaining cable path, but the system is no longer fault-tolerant until the connection is restored.

Q4: Is this cable compatible with both M-Series and S-Series hardware?

A4: Yes, the LocalBus physical layer is consistent across these DeltaV generations, provided the carriers utilized support the standard multi-pin LocalBus interface.

 

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...