1 / 3

GE Multilin Universal Relays UR-8GH | 4 CT/4 VT Input Module

GE Multilin Universal Relays UR-8GH | 4 CT/4 VT Input Module

Only 3 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-8GH

  • Country of origin:Egyesült Államok

  • Product Type: 4 CT/4 VT Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1350g

  • Dimensions: 15 cm x 18 cm x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The UR-8GH (UR8GH) is a high-precision analog data acquisition interface engineered by General Electric for the UR Series (Universal Relays) network protection ecosystem. Functioning as a high-density primary scaling block, this critical card safely steps down high-capacity voltage and current dynamics from field instrument transformers into millivolt processing lines for the relay's arithmetic core. Power distribution infrastructures—including extra-high voltage transmission switchyards, automated hydroelectric stations, and heavy petrochemical processing facilities—rely on the UR-8GH (UR8GH) to capture sub-cycle line disturbances and voltage phase fluctuations. By providing 4 CT (Current Transformer) and 4 VT (Voltage Transformer) galvanically isolated input channels on a single substrate, this module ensures accurate real-time line calculation metrics, shortens breaker response profiles during high-current line faults, and minimizes plant unprogrammed downtime.

Technical Configuration & Sensor Interfacing

The advanced structural wiring matrix, channel segregation filters, and operational frequency boundaries of the UR-8GH measurement module govern its grid monitoring precision.

  • Dual-Source Parameter Ingestion: Features a balanced 4 CT and 4 VT channel grid configuration designed to track three-phase voltage and current lines simultaneously along with an independent neutral ground path.

  • Galvanic Protection Boundaries: Implements an advanced structural isolation barrier between the terminal connection block and the internal processing backplane, preventing severe inductive fault spikes from damaging the core CPU processor.

  • Sub-Sample Phase Synchronization: Operates in perfect synchronization with the Universal Relay backplane logic, ensuring zero phase-angle skewing between corresponding current and voltage waveform samplings.

  • Dynamic Grid Mapping Matrix: Transmits high-fidelity analog values to the host system firmware to support complex protective logic paths, including distance protection (21), directional overcurrent (67), and synchronized line monitoring telemetry.

Technical Specifications

Protection Metric Factory System Specification Standard
Model Designation UR-8GH
Brand Manufacturer GE Multilin (General Electric Grid Solutions)
Control System Line UR Series Universal Relays Platform
Module Classification 4 CT / 4 VT Standard Analog Input Module
Current Inputs (CT) 4 Isolated Channels with high continuous thermal bounds
Voltage Inputs (VT) 4 Isolated Channels optimized for instrumentation lines
Frequency Tracking Bounds 50 Hz / 60 Hz Nominal Grid Compatibility
Data Log Resolution High-speed multi-sampling analog-to-digital matrix
Configuration Software EnerVista UR Configuration Utility Platform
Physical Dimensions Standard UR Expansion Slot Case (approx. 15 cm x 18 cm x 4 cm)
Hardware Shipping Weight 1.35 kg
Operating Temperature Window -40 to +60 deg C Continuous Environmental Range
Manufacturing Location Markham, Ontario, Canada

Protection System & Diagnostic FAQs

How do system engineers verify individual CT/VT calibration or troubleshoot open-circuit metrics on the UR-8GH?

Live analog vector measurements can be evaluated passively via the front LCD panel of the Universal Relay chassis or diagnosed directly through the EnerVista UR software workspace. This programming environment displays real-time current magnitude graphs, phase angles, and harmonic wave distortions, allowing immediate diagnosis of current transformer phase reversals or ungrounded neutral lines.

What are the consequences of an unprogrammed open-circuit fault crossing an active UR-8GH current transformer channel?

An open-circuit condition on an active CT secondary loop generates dangerous high-voltage transients across the terminal block pins, posing a lethal shock hazard to personnel and causing dielectric breakdown within the module's input circuitry. Technicians must ensure that shorting blocks are securely engaged prior to disconnecting any current line terminal screws.

Can the UR-8GH module be swapped or inserted while the utility automation panel remains live?

No. To prevent lethal induced voltages from open CT lines, accidental tripping of live substation breakers, or damage to the internal backplane microprocessor from electrical arcs, you must completely isolate all power and current transformer sources from the relay enclosure before extracting or seating any module.


Field Engineering & Installation Protocol

  • Terminal Screw Landing Constraints and Torque Specifications:

    When landing heavy instrument transformer leads onto the terminal block of the UR-8GH, utilize high-integrity ring terminals to prevent wire pullouts. Insert wire links cleanly and tighten terminal screws to an exact torque profile of 1.4 N-m (12.4 inch-lbs). Loose current terminal connections cause resistive heating and can induce high-voltage arcing that destroys the underlying PCB solder points.

  • Twisted-Pair Shielding and Noise Suppression Guidelines:

    Route all sensitive analog current and voltage transformer secondary circuits through dedicated, shielded twisted-pair instrumentation lines. Ground the cable shields at a single point inside the relay panel enclosure only. This installation rule blocks high-frequency electromagnetic noise generated by adjacent high-voltage circuit breakers from distorting the relay's phase-angle measurements.

  • Module Insertion Security and Grounding Path Integrity:

    Carefully slide the UR-8GH board into its designated panel slot using the built-in plastic guide rails to protect the rear multi-pin pinout from alignment damage. Push the module home until its metal faceplate sits completely flush against the chassis housing, and tighten all exterior retention screws to a maximum torque profile of 0.6 N-m (5.3 inch-lbs). This structural connection establishes a low-resistance earth ground path to protect the internal data acquisition components from heavy substation electromagnetic interference (EMI).

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...