1 / 3

GE Multilin UR-6UH UR Series Digital I/O Module

GE Multilin UR-6UH UR Series Digital I/O Module

Only 4 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-6UH

  • Country of origin:Kanada

  • Product Type: Digital I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1150g

  • Dimensions: 18 cm x 15 cm x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The GE Multilin UR-6UH is a high-performance modular plug-and-play component designed for the Universal Relays (UR) series to facilitate discrete status monitoring and auxiliary asset management. This specific digital input/output variant provides the core relay chassis with six Form-A outputs (without monitoring capabilities) and four high-speed digital contact inputs. Operating as a reliable intersystem communications link within a substation network, the GE Multilin UR-6UH enables real-time supervision and automated physical control over external switchgear and field breakers. By using direct discrete binary encoding instead of traditional unshielded analog circuits, this card significantly limits baseline electrical noise propagation and minimizes hardware deployment costs across automated power grid environments.

Features

  • Optimized Discrete Density: Configured with 4 independent digital contact inputs engineered for real-time telemetry verification of secondary substation state transitions.
  • Form-A Relay Contacts: Equipped with 6 Form-A standard outputs tailored for robust open/close control signaling over auxiliary switchgear components.
  • Modular Plug-and-Play Footprint: Engineered for rapid slot exchange inside the UR series frame, facilitating fast uptime and reduced field servicing times.
  • Enhanced Noise Suppression: Native digital architecture produces less electrical noise cross-talk compared to conventional unshielded analog processing interfaces.
  • Dual-Interface Calibration: Supports unified software configuration via the EnerVista UR platform as well as direct physical adjustment through the front panel keypad and integrated LCD.

Applications

  • Distributed monitoring of substation auxiliary switches and breaker status loops.
  • Interlocking and safety command routing across primary utility control networks.
  • Real-time contact monitoring and local alarm initiation inside industrial automated switchgear.
  • Remote equipment management and status tracking in transmission distribution centers.

Ordering Information

Suffix Code Description
6U 6 Form-A (No Monitoring) Outputs, 4 Digital Inputs
H Standard/High-Voltage Hardware Interface Suffix

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Manufacturing Location Ontario, Canada
Module Series Type Universal Relays (UR) Series Platform
Configuration Code 6U (6 Form-A Outputs / 4 Digital Inputs)
Output Feature Profile No Monitoring
System Interface Configuration EnerVista UR Software / Front Panel Keypad & LCD
Weight 1.15 kg
Dimensions (L x W x H) approx. 18 cm x 15 cm x 4 cm

Installation Guidelines

Slot Replacement and Insertion

Completely isolate the main Universal Relay housing from any active auxiliary control power lines before handling. Align the outer structural boundaries of the module card along the designated rear card guides (typically slots H, M, P, U, or W) and apply continuous force until the pin block seats firmly onto the backplane. Secure the structural thumb latch retaining screws.

Interface Mapping and Setup

Once the module is locked in place, activate the relay mainframe and launch the EnerVista UR utility program on a connected workstation to register the new hardware configuration. Alternatively, adjust contact processing logic variables manually using the front-panel matrix button array and localized text display screen.

Signal Separation

Ensure all digital connection runs leading to the discrete input pins are physically routed away from primary alternating current (AC) power lines and raw unshielded current transformer (CT) lines to maintain absolute signal integrity against inductive voltage surges.

Key Features:

Does the UR-6UH module feature internal current or voltage monitoring for its relay outputs?

No, this specific module variation provides standard six Form-A outputs without any built-in current or voltage monitoring circuitry.

Which available slots on a T60 relay chassis can host this digital I/O card?

According to the universal order code structure, digital I/O modules can be integrated into positions designated by slots H, M, P, U, or W.

What interface options are available to modify the parameters of this module after a field replacement?

System parameters can be adjusted electronically using the EnerVista UR software suite or directly via the physical front-panel buttons and built-in LCD interface.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Kanada

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...