1 / 3

HIMA F 7105A 6-Fold Current Distribution Module with Fuse Monitoring

HIMA F 7105A 6-Fold Current Distribution Module with Fuse Monitoring

Only 10 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: F7105A

  • Country of origin:Németország

  • Product Type: Power Distribution Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 2.1cm x 19.1cm x 12.9cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The F 7105A (F7105A) is a high-reliability 6-fold current distribution module designed for the HIMA rack-based safety systems. Its primary function is to provide protected power distribution to various subracks and system components while ensuring continuous line health monitoring. The module features six independent current paths, each equipped with a fuse and a dedicated status LED. In critical infrastructure such as refineries or power plants, the F 7105A plays a vital role in localized power management, preventing a single short circuit from taking down an entire safety controller rack. With its integrated error relay contact, it provides immediate feedback to the central diagnostic system the moment a fuse blows, drastically reducing MTTR (Mean Time To Repair).

Technical Configuration

The F 7105A is engineered for mechanical simplicity and electrical robustness:

  • Distribution Capacity: Six fused current paths, typically supplied with 4 A-T (time-delay) fuses from the factory.

  • Fuse Monitoring: Each path is monitored for integrity. If a fuse blows, a red "ERR" LED flashes and a potential-free changeover contact opens for remote signaling.

  • Visual Diagnostics: Features six green path-status LEDs and one red common error LED on the front panel.

  • Redundant Supply: Pins z2 and z4 allow for the parallel supply of 24 VDC operating voltages, ensuring the distribution bus remains energized even if one supply line is compromised.

  • Switching Logic: The monitoring relay contact operates with a switching time of approximately 60 ms, providing rapid notification of power distribution faults.

Technical Specifications

Feature Details
Model F 7105A
Brand HIMA
Number of Paths 6 Fused Paths
Fuse Rating Max 4 A-T (Standard)
Supply Voltage 24 VDC (-15 percent ... +20 percent)
Current Consumption 65 mA (Internal)
Relay Contact Potential-free changeover contact
Operating Temp -25 to +70 deg C
Space Requirement 4 TE (Total Units)
Weight 0.25 kg

Technical FAQs

Does the "ERR" LED light up if a current path is not connected?

No. If a current path is not connected to a load, the corresponding green LED remains off, but the output relay contact remains closed. The module only monitors "connected" paths where a fuse has physically blown.

What is the maximum switching capacity of the error relay?

The integrated relay can handle up to 4 A at 30 VAC/DC. For inductive loads, it is rated for a maximum switching power of 120 W (non-inductive) or 120 VA (cos phi > 0.5).

Can I replace the standard 4 A-T fuses with a different rating?

While 4 A-T is the factory standard, you may use smaller fuses for specific line protection. However, you should never exceed the 4 A rating per path to avoid overheating the backplane traces or the module's internal circuitry.


Engineering & Installation Guide

  • Fuse Replacement Safety: Before replacing a blown fuse, always investigate the root cause of the overcurrent. The red flashing "ERR" LED and the specific path LED will help you identify which branch circuit failed. Ensure the power is isolated before physical fuse extraction.

  • Parallel Supply Wiring: To maximize system availability, utilize both the z2 and z4 pins to connect redundant 24 VDC power sources. This ensures that the six distribution paths remain active even if one primary power supply unit fails.

  • Relay Contact Integration: Connect the potential-free changeover contact (pins 2 and 4) to a digital input on your HIMA safety CPU. This allows you to generate a system-level alarm in the SILworX or ELOP II software whenever a power distribution fault occurs.

  • Environmental Considerations: The module is rated for -25 to +70 deg C, making it suitable for unheated outdoor cabinets. However, ensure that the cabinet has adequate ventilation if multiple F 7105A modules are used at full 4 A capacity, as the cumulative heat from the fuses can affect internal cabinet temperatures.

Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA F 7105A 6-Fold Current Distribution Module with Fuse Monitoring

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete Zöld
Country of origin
Németország
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...