1 / 1

Honeywell 51453328-501 UDA Series Additional Analog & Relay Card

Honeywell 51453328-501 UDA Series Additional Analog & Relay Card

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51453328-501

  • Country of origin:Egyesült Államok

  • Product Type: Analyzer Expansion Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Providing extended output capabilities for continuous process monitoring systems, this hardware expansion board, the Honeywell 51453328-501, integrates directly into the host UDA2182 Universal Dual Analyzer chassis. This card increases the control and alarm-handling capabilities of your process analyzer by introducing supplementary auxiliary analog outputs and dedicated physical relay contacts, ensuring seamless signal transmission to distributed control systems (DCS) or auxiliary control loops.

Features

  • Expands host analyzer capabilities to support additional physical control and alarm loops.
  • Provides isolated analog output channels for highly reliable process variable retransmission.
  • Integrated dry relay contacts configurable for high/low alarms, diagnostics, or limit controls.
  • Ruggedized field terminal blocks designed for secure industrial wire terminations.
  • Plug-and-play form factor simplifies field upgrades and minimizes system downtime.

Applications

  • Municipal water treatment facilities using Honeywell UDA2182 multi-parameter analyzers.
  • Industrial boiler feed-water monitoring systems demanding auxiliary signal retransmission.
  • Chemical processing plants requiring automated hardwired shutdown actions via relay interlocks.
  • Wastewater neutralization and effluent monitoring systems.

Technical Specifications

Manufacturer Honeywell
Part Number 51453328-501
Series Compatibility UDA2182 Universal Dual Analyzer
Module Type Additional Analog Output and Relay Card
I/O Functionality Auxiliary Analog Output & Relay Contact Outputs
Installation Slot Internal Dedicated Option Slot
Shipping Weight (Calculated) 1.0 kg

Alternative Models & Compatibility

The 51453328-501 card is specifically engineered for the UDA2182 analyzer series. When replacing older module revisions or retrofitting legacy analytical instrumentation, confirm that the host analyzer's firmware supports the additional analog and relay configuration options in the setup menu. Ensure the host unit's power supply capacity aligns with the overall system card loading before installation.

Application Pitfalls & Engineering Notes

To prevent cross-talk and measurement instability, signal loop cables must be isolated from high-voltage AC lines. Do not run low-voltage analog signal wires inside the same conduit as high-current relay switched lines. Inductive load switching with the on-board relays requires external snubber protection to avoid transient voltage feedback to the card circuitry.

Installation Guidelines

CRITICAL WARNING

Disconnect all electrical power to the host analyzer and verify the absence of voltage before opening the enclosure door. Failure to isolate the power supplies can cause severe shock, card damage, or system-wide communication faults.

1 Power down the UDA2182 host analyzer and secure with lock-out/tag-out procedures.
2 Open the main housing and locate the designated option slot on the internal chassis.
3 Carefully align the edge connector of the 51453328-501 card with the motherboard socket and press firmly until fully seated.
4 Secure the card with mounting screws to prevent vibration-induced dislodgement.
5 Terminate the analog signal and relay loop cables onto the plug-in terminal blocks, ensuring correct polarity.

What is the primary function of the Honeywell 51453328-501 card?

It is an option board designed to expand the input/output capacity of a UDA2182 Universal Dual Analyzer, providing additional physical relays and analog outputs.

Does the UDA2182 require firmware upgrades after installing this card?

The card is designed to be auto-detected by standard UDA2182 firmware, but it is recommended to verify firmware compatibility and menu options if upgrading older analyzers.

Can I hot-swap this card while the analyzer is running?

No. Power down the host instrument completely before inserting or removing the 51453328-501 card to avoid physical damage to the module or host motherboard.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...